The Response ConverterTM network interface allows you to convert 192 DMX512 signals
to AMX192 or 192 AMX192 signals to DMX512. The compact interface box features an
optically isolated DMX512 link and a 100 hertz output update rate. This manual provides
information on all Response Converter controls, connectors and indicators.
TM
DMX512 Input➊
DMX512 Output❷
AMX192 Output❸
AMX192 Input❹
Reset switch➎
Indicator LEDs➏
DMX512 termination switch❼
Adjustment pots❽
DIP switches➒
Number switches❿
AC power cable
➊
PUSH
3
2
3
1 2 3 4 5 6 7 8
❽❼➏➎
➒➓
3
2
4
4
1
1
5
5
0
6
6
9
9
7
8
7
8
2
4
1
5
0
6
9
7
8
3
2
1
0
9
8
❹❸❷
PUSH
4
5
6
7
11
11
To use Response Converter, follow these steps:
1. Plug power cable into a 120 VAC outlet.
2. For DMX512 to AMX192 operation, set DIP switch 3 down and switch 4 up. If optical
isolation is desired, set DIP switch 1 up. For AMX192 to DMX512 operation, set DIP
switch 1 down, switch 3 up and switch 4 up.
3. Press Reset.
4. Insert input and output cables into appropriate connectors.
5. Set number switches to starting dimmer output number (see page 2).
6. If Response Converter is the last device in a DMX512 data link, set DMX512
terminator switch On (right). In AMX192 to DMX512 mode, leave terminator switch Off
(left).
7. See following pages for adjustment pot settings and additional information on switch
functions and settings.
Note: When data flow is interrupted, all outputs fade to zero percent after three minutes.
Page 2
Entering starting analog dimmer address
100
The rotary number switches allow you to set the control signal number for the first
output dimmer. The remaining 191 analog outputs are consecutively numbered from
that number.
Set the rotary number switches to a starting number between 001 and 512 for
DMX512 to AMX192 operation. For AMX192 to DMX512 operation, enter a starting
number between 001 and 192. The Response Converter reads numbers over the output
quantity limit as a starting address of 1. You do not have to press Reset when
resetting the starting address, unless you are also ending a diagnostic test.
Performing diagnostic tests
Six diagnostic tests are provided on the Response Converter. The first two digits
entered on the number switches specify the type of test; the third digit determines the
rate at which it runs. To run a test, follow these steps:
1. Enter the two-digit test number on the left and center rotary number switches. See
below for test numbers and descriptions.
2. Enter a rate number on the right number switch.
For each test, the third digit determines the rate at which the test runs. When the
third digit is set at 0, the test pauses; when the third digit is set at 1, test runs at
its minimum rate; at 9 it runs at its maximum rate.
3. Press Reset to start test.
4. To stop test, enter a three-digit starting dimmer number from 001 to 192 on the
number switches, and press Reset.
Chase
019
The Chase test flashes each of the 192 dimmers to full intensity in a chase sequence.
Set first two number switches to 91.
Fade All
029
The Fade All test simultaneously fades all dimmers to full intensity, and then back
down to zero intensity. Set first two number switches to 92.
Fade Chase
039
The Fade Chase test fades each of the 192 dimmers to full intensity, and then back to
zero intensity in a chase sequence. Set first two number switches to 93.
Selected Output to Full
049
The Selected Output to Full test sets a selected dimmer output to full intensity and
holds it there. Set first two number switches to 94, and press Reset. Then enter
dimmer number from 001 to 192.
All to Percent
059
The All to Percent test sets all dimmer outputs to an intensity percentage you
specify and holds them there. Set first two numbers to 95, and press Reset. Then enter
any three-digit percentage between 000 and 100 on the number switches.
All to DMX512 Level
069
The All to DMX512 Level test sets all dimmer outputs to an intensity level you set
and holds them there. DMX512 level changes the output scale from 0-100 (percent
output intensity) to 0-255 (DMX512 data format). Set the first two numbers to 96, and
press Reset. Then enter a DMX512 intensity level between 000 and 255 on the
number switches.
Page 2 • Response Converter User Manual
Page 3
DMX512 pinout
1 - Common
2 - Data (-)
3 - Data (+)
4 - No connection
5 - No connection
AMX192 pinout
1 - Common
2 - Clock (+)
3 - Analog levels
4 - Clock (-)
Output
Input
Input
Output
DMX512 connectors
1
Response Converter has two 5-pin XLR connectors, a male connector for DMX512
input and a female connector for DMX512 output.
AMX192 connectors
1
1
Response Converter has two 4-pin XLR connectors, a female connector for AMX192
input and a male connector for AMX192 output.
Reset switch
1
Pressing the Reset switch forces the microprocessor to reread DIP switch and number
switch settings.
You must press Reset to activate DIP switch setting changes and to start and stop
diagnostic tests. You do not have to press Reset when you change the starting dimmer
number (unless you are also ending a diagnostic test).
Indicator LEDs
Data
Power
Max
AMX
out
Top LED continuousReceiving valid data
Top LED blinkingReceiving invalid or no data
Bottom LED continuous Receiving power
DMX512 termination switch
Set the termination switch On (right) if the Response Converter is the last device in a
OnOff
DMX512 data stream. If you are sending a DMX512 data stream to another interface
or dimming device, set the termination switch Off (left). For AMX192 to DMX512
operation, set terminator switch Off (left).
Potentiometers
The Response Converter has two potentiometers, one adjusts maximum AMX192
Max
AMX
in
input levels, and one adjusts maximum AMX192 output levels.
AMX192 maximum output level
The left pot adjusts the maximum AMX192 output level. Turn pot clockwise to
increase maximum output level, or counterclockwise to decrease it. When shipped
from the factory, maximum AMX192 output level is set at 5 volts.
AMX192 maximum input level
The right pot adjusts the maximum AMX192 input level. Turn pot clockwise to
increase maximum input level, or counterclockwise to decrease it. When shipped from
the factory, maximum AMX192 input level is set at 5 volts.
Response Converter User Manual • Page 3
Page 4
DIP switch settings
4
1 2 3 4 5 6 7 8
3
DIP switch settings determine DMX512 or AMX192 operation mode and enable and
disable optical isolation. See below for DIP switch settings; set all unused DIP
switches in the down position.
Operation mode
Set DIP switches 3 and 4 according to chart below to select DMX512 or AMX192
operation.
Switch 3Switch 4
DMX512 to AMX192 operationDownUp
AMX192 to DMX512 operationUpUp
Enable/disable optical isolation
Optical isolation creates a physical break between the Response Converter and a
DMX512 link to help prevent accidental high voltage potentials from damaging other
equipment on the DMX512 link. Optical isolation must be disabled for AMX192 to
DMX512 operation. See chart for DIP switch settings to enable and disable optical
isolation.
Switch 1
Optical isolation enabled (DMX512 to AMX192)Up
Optical isolation disabled (AMX192 to DMX512)Down
1
AC power
The Response Converter has an operating range of 90 to 140 volts with optimal
performance at 110 volts. It has an internal type GMA-1/2 fuse. Disconnect power
before replacing fuse.
Specifications
Dimensions2.25"H x 6"W x 7"D
Weight3 pounds
Processing speed100 hertz
Electronic Theatre Controls, Inc.
3030 Laura Lane
Middleton, WI 53562
608/831-4116 FAX 608/836-1736
Copyright 1991-95 Electronic Theatre Controls, Inc.
Page 4 • Response Converter User Manual
Specifications subject to change. Revised 2-91.