ETC ColorSource Spot, CSSPOTSDB-DPJ-10 Installation Guide

ETC Installation Manual
Small screw included with the shutter barrel
ColorSource Spot light engine
ColorSource® Spot

Overview

The ColorSource Spot is an affordable profile fixture that offers the quality and support of an ETC LED fixture. Utilizing an RGB-L color mixing system, the ColorSource Spot produces amazing color and output for a four-color fixture. This light engine can be used with standard ETC shutter barrels, lens tubes, Fresnel and Cyc Adapters, and accessories.
CAUTION:

Environment

The ColorSource Spot operates in ambient temperatures of 0°- 40°C and comes with a variable-speed, quiet operation fan.
Note:
Note:

Electrical

WARNING:
• Operates between 100V and 240VAC at a frequency of 50/60Hz.
• Up to 9 luminaires (15A max) may be linked via power thru connector (10 luminaires total per circuit) when used with an R20 relay module or Unison Echo Relay Panel. Consult breaker trip curves when used with other equipment. Requires power from a non-dimmable source.
• Risk of eye injury. Do not stare directly into the light.
• Do not operate in proximity to flammable materials.
The ColorSource Spot is for use in dry locations only.
• Maximum recommended ambient operating temperature: Ta = 40°C (104°F)
• Maximum anticipated external surface temperature at 40° ambient: Tmax = 80°C (176°F)
• External temperatures after 5 minutes of full-brightness operation at 25°C (77°F) ambient: 30°C (86°F)
• External Temperature (steady state achieved) at 25°C (77°F): 36°C (97°F)
Disconnect the fixture from power and DMX and allow it to cool before performing any cleaning and maintenance.

Installing a shutter barrel

The ColorSouce Spot can be purchased with or without a shutter barrel. To install a shutter barrel you will need a #2 Phillips Screwdriver. (not provided)
The ColorSource light engine includes a barrel screw. The small screw used to secure the top of the shutter barrel is included with the shutter barrel.
Step 1: Align the barrel to the front of the
ColorSource Spot and rotate it one quarter turn counter-clockwise
ColorSource Spot Page 1 of 4 Electronic Theatre Controls, Inc.
Step 2: Insert the shutter barrel into the front of the
light engine and rotate clockwise until it is fully threaded onto the light engine.
Corporate Headquarters  Middleton, WI, USA  Tel +608 831 4116  Service: (Americas) London, UK  Tel +44 (0)20 8896 1000  Service: (UK) Rome, IT  Tel +39 (06) 32 111 683  Service: (UK) Holzkirchen, DE  Tel +49 (80 24) 47 00-0  Service: (DE) Hong Kong  Tel +852 2799 1220  Service: (Asia) Web: www.etcconnect.com  © 2015 ETC. All Rights Reserved.  Product information and specifications subject to change.
7413M2100
Rev A  Released 2015-05  ETC intends this document to be provided in its entirety.
service@etceurope.com
service@etceurope.com
techserv-hoki@etcconnect.com
service@etcasia.com
service@etcconnect.com
ETC Installation Manual
ColorSource Spot
Step 3: Insert the barrel screw at the bottom of the light engine and tighten. Step 4: Insert the small screw into the top of the light engine and tighten using the Phillips

Mounting hardware

• The ColorSource Spot ships with a standard yoke for mounting with a c-clamp.
• The provided safety cable (or other approved safety device) must be attached to the fixture. Two attachment loops are provided on the rear of the fixture body. Take care to leave as little slack as possible in the safety cable to avoid catching the yoke of the fixture.

Connectors

Power Connectors - two PowerCON connectors for power in and thru
Data in and Thru: DMX512/RDM -
screwdriver
• two five pin XLR connectors OR
• two RJ45 connectors
Note:
Note:
This fixture is not Ethernet/data network compatible.
The ColorSource Spot is not self terminating. You must terminate the last fixture in line with a 120 ohm resistor. XLR terminators are not available from ETC.
To purchase an RJ45 terminator, please contact your ETC customer service representative and request part number N4086.

Fixture setup

Step 1: Plug power cord into the PowerCON in connector on the rear of the fixture. Step 2: Make any power-thru cable connections prior to applying a power source. Step 3: Plug power cord into power source.

Power up

Step 1: Press the Mode button once to wake the display. The first screen you see displays the
DMX address.
Step 2: Press the Mode button a second time to access the Presets/Sequences screen.

Adjusting the tilt

The fixture can be tilted up and down and rotated (panned) as needed.
Step 1: Loosen, but do not remove the yoke locking knobs. Step 2: Tilt the fixture to the desired angle. Step 3: Tighten the yoke locking knobs.

User interface

The user interface allows you to set the start address of the fixture, and access the stand-alone presets and sequences. After five seconds of inactivity, the display goes dark

User interface lock

To lock: Press and hold the up and down arrows for three seconds to lock the user interface. The
UI will show “Loc” when locked.
To unlock: Press and hold the up and down arrows for three seconds to unlock the user interface.
ColorSource Spot Page 2 of 4 Electronic Theatre Controls, Inc.