eta K PLUS, K PLUS 1504, KA PLUS, K PLUS 1005, K PLUS 0510, K PLUS 0808, K PLUS 0501, K PLUS 0218, KA PLUS 103.5, KA PLUS 1801, KA PLUS 1503, KA PLUS 085.5, KA PLUS 057.5, KA PLUS 0213, K AC PLUS 1018, K CO PLUS, K PLUS 1802 Operating Manual
This operating instructions contains safety information that if ignored can endanger life or result in
serious injury.
Read these instructions carefully before use and keep them for future reference. The original instruction
is in Italian. All non-Italian instructions are translations of the original instruction.
Information and specifications on this manual could be uncorrect or could have printing errors.
Specifications are subject to change without notice.
Version: R1-11-13
NORME CE
EC RULES (STANDARD EC)
NORMAS DE LA CE
Direttiva Basso Voltaggio
Low Voltage Directive
Directiva de baja tensión
Norme armonizzate europee nell’ambito della direttiva
European harmonized standards underdirective
Las normas europeas armonizadas conforme a la directiva
K METERING PUMP IS TESTED AND CERTIFIED BY WQA TO NSF/ANSI 50 AND 61 FOR
MATERIALS SAFETY.
2006/95/CE
⎬
2004/108/CE
⎬
2006/42/CE
⎬
ICON
2
GENERAL SAFETY GUIDELINES
Operating, installing, or maintaining the unit in any way that is not covered in this manual could cause
death, serious personal injury, or damage to the equipment.
This manual use the following safety message icon:
Danger!
Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
Warning!
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
Important - A practice not related to personal injury or additional information.
Cross reference - An instance which refers to related information elsewhere in the same document
⎘
PURPOSE OF USE
AND SAFETY
METERING PUMP IS INTENDED FOR CHEMICAL DOSING.
Do not use in explosive area (EX).
Do not use with flammable chemicals.
Do not use with radioactive chemicals.
Use after a proper installation.
Use the pump in accordance with the data and specifications printed on the label.
Do not modify or use in a manner inconsistent with the provisions of the operating manual.
Keep the pump protected from sun and water. Avoid water splashes.
In emergencies the pump should be switched off immediately. Disconnect the power
cable from the power supply.
When using pump with aggressive chemicals observe the regulations concerning the
transport and storage of aggressive fluids.
When installing always observe national regulations.
Manufacturer is not liable for any unauthorized use or misuse of this product that may
cause injury, damage to persons or materials.
Pump must be accessible at all times for both operating and servicing. Access must
not be obstructed in any way.
Feeder should be interlocked with a no-flow protection device.
Pump and accessories must be serviced and repaired by qualified and authorized
personnel only.
Before any operation:
• always read chemical Material Safety Data Sheet (MSDS);
• always wear protective clothing;
• always discharge the liquid end before servicing the pump.
• empty and rinse the liquid end before work on a pump which has been used with
hazardous or unknown chemicals.
•
This equipment requires regular maintenance to ensure potability requirements of the
water and maintenance of improvements as declared by the manufaturer.
Feeder should be interlocked with a no-flow protection device to automatically
shut-off the pumps when there is no flow!
Adequate measures shall be taken to prevent cross connection of chemicals!
Chemical feeding must be stopped during backwash cycles and periods of noflow as
these conditions may introduce the potential for chemical overdosing. Not doing so
may result in elevated chemical concentrations and hazerdous gas introduction into
the pool or spa.
3
ENVIRONMENTAL
SAFETY
Work area
Always keep the pump area clean to avoid and/or discover emissions.
Recycling guidelines
EWC code: 16 02 14
Always recycle according to these guidelines:
1. If the unit or parts are accepted by an authorized recycling company, then follow local recycling
laws and regulations.
2. If the unit or parts are not accepted by an authorized recycling company, then return them to
the nearest representative.
Waste and emissions regulations
Observe these safety regulations regarding waste and emissions:
• Dispose appropriately of all waste.
• Handle and dispose of the dosed chemical in compliance with applicable environmental
regulations.
• Clean up all spills in accordance with safety and environmental procedures.
• Report all environmental emissions to the appropriate authorities.
LABEL
Distributor
CODE: pump code
MODEL: pump model
PUMP’S DATA
S/N: serial number
SPARE PARTS
Fig. 1. Product label.
QR
code
For spare parts orders or any other communication, refer to the pump’s label.
Code (CODE) and serial number (S / N) uniquely identify the pump.
Fig. 2. WQA label.
THIS METERING PUMP IS TESTED AND CERTIFIED
BY WQA TO NSF/ANSI 50 AND 61 FOR MATERIALS
SAFETY.
Data
matrix
4
Transportation and
storage
A not suitable transportation or storage can cause damages.
Use origianal box to pack the pump.
Observe storage conditions also for transportation.
Although packed, always protect the unit against humidity and the action of
chemicals.
Before return the dosing pump to the manufacturer Repair service, drain the chemical
from pump head and rinse it. Refer to ⎘ Shutdown procedure.
Fill the PRODUCT SERVICE REPAIR FORM and send it with the dosing pump.
Repair service is not accepted if PRODUCT SERVICE REPAIR FORM is missing.
DO NOT TRASH PACKAGING. USE IT TO RETURN THE PUMP.
Transportation and storage temperature ..... 10 ÷ 50°C (32 ÷ 122°F)
K PLUS is a constant or proportional dosing pump with level control for chemical feeding into water.
In Constant dosing mode pump doses a constant quantity regularly as configured by the user.
In Proportional dosing mode pump doses a quantity proportionally to an input signal, digital (voltage
free contact) or current (mA).
Working modes available:
• constant
• constant with 1-10 pulses divider
• multiplier with 1-10 pulses divider
• divider with 1-10 pulses divider
• divider with 1-100 pulses divider
• divider with 1-1000 pulses divider
• mA current signal (0/4 mA = 0 pulses: 20mA = max pulses)
Flow rate is determined by the stroke length and by the stroke speed. The stroke length is adjustable
from 0 to 100% using the stroke length adjustment knob. However dosing accuracy is guarantee
within an adjustment range from 30% to 100%.
K CO PLUS works in constant mode.
The pump can be set to work in
• constant
• constant with 1-10 speed reducer.
K CL PLUS works in constant mode and has got level control.
NSF/ANSI 61
Self venting:
KA PLUS
NSF/ANSI 61
6
The pump can be set to work in
• constant
• constant with 1-10 speed reducer.
KA is the K version with self-venting pump head.
Self-venting pump head must be used when using chemicals that produce gas (i.e. hydrogen peroxide,
ammonium, sodium hypoclorite at particular conditions).
For connections ⎘ “Self-Venting pump head installation”.
Fig. 3. K PLUS - KA PLUS
1
2
3
4
5
K PLUS- detail on pump head with manual
venting
Venting knob
Delivery valve
To manual
venting hose
Suction valve
KA PLUS - detail on self venting pump
head mod. LA, MA, NA
Working UR % .......................................... 85% at t ≤40 °C; 70% at 50 °C (no condensing water)
Max installation height .............................1,5 m
Capacity ..................................................⎘ Table 1 and 2
Tab. 1. Capacity (manual and self venting models)
cc per
stroke *
minmax
cc per
stroke *
minmax
max
l/h
max
l/h
Flow
Flow
Min
GPH
Min
GPH
Max
GPH
Max
GPH
Mod.
K PLUS
18020,0620,0000160,530,060,19
15040,1140,0000291,060,110,37
10050,1450,0000371,320,140,46
08080,2280,0000582,110,220,74
05100,28100,0000742,640,280,93
05010,2810,0000080,30,030,09
02180,50180,000134,760,501,67
Mod.
KA PLUS
18010,0310,0000080,260,030,09
15030,0830,0000210,790,080,28
103.50,103,50,0000260,920,100,32
085.50,155,50,0000401,450,150,51
057.50,217,50,0000551,980,210,69
02130,37130,0000983,430,371,20
* cc per stroke: referred to cc/stroke with stroke length knob on 100%.
cc/h
cc/h
min
min
CAPACITY
pulse/
min
180
180
180
180
180
180
180
pulse/
min
180
180
180
180
180
180
Max
pressure
barPSI
18261
15217
10145
8116
572
572
229
Max
pressure
barPSI
18261
15217
10145
8116
572
229
peak Amps
(A)
230
115
VAC
VAC
2.71.45
2.71.45
2.71.45
2.71.45
2.71.45
2.71.45
2.71.45
peak Amps
(A)
230
115
VAC
VAC
2.71.45
2.71.45
2.71.45
2.71.45
2.71.45
2.71.45
Delivery
(PVDF)
Delivery
(PVDF)
Suction
hose
4 x 64 x 6L
4 x 64 x 6L
4 x 64 x 6L
4 x 64 x 6L
4 x 64 x 6L
4 x 64 x 6L
6 x 86 x 8M
hose
4 x 64 x 6LA
4 x 64 x 6LA
4 x 64 x 6LA
4 x 64 x 6LA
4 x 64 x 6LA
6 x 86 x 8MA
hose
Suction
hose
Pump
head
Pump
head
8
Tab. 2. Capacity (compressed air model)
CAPACITY
Flowcc per
Modello
K AC PLUS
* cc per stroke: referred to cc/stroke with stroke length knob on 100%.
min
max
cc/h
10180.6180.164.70.62101456 x 86 x 8M
Min
l/h
GPH
Max
GPH
stroke *
minmax
Max
pressure
barPSI
Delivery
hose
(PVDF)
Suction
hose
Pump
head
Manual
stroke length
adjustment
Materials
Max cc/stroke ( ⎘Construction Materials and Technical info) are referred to cc/stroke with
stroke length knob on 100%.
The stroke length knob adjusts the pump capacity. Press and rotate the knob when the pump is powered.
Dosing accuracy is guarantee within an adjustment range from 30% to 100%.
Note:if knob isn’t on 100% position then the pump will dose at pressure greater than the one
declared on label.
✓ : standard
✗: options available
PVDF PP PPV0 PMMA PVC PE CE VETRO PTFE SS FKM B EPDM WAX SI
The operator must be aware of safety precautions to prevent physical injury.
User health and
safety
The work area
Pump location
POWER SUPPLY DISCONNECTION
Disconnect power supply before you perform any installation or maintenance tasks.
Failure to disconnect power will result in serious physical injury.
SAFETY EQUIPMENT
Use safety equipment according to the company regulations. Use this safety
equipment within the work area:
• Helmet
• Safety goggles (with side shields)
• Protective shoes
• Protective gloves
• Gas mask
THE WORK AREA
Observe these regulations and warnings in the work area:
• Always keep the work area clean.
• Pay attention to the risks presented by gas and vapors in the work area.
• Avoid all electrical dangers. Pay attention to the risks of electric shock or arc
flash hazards.
• Avoid water splashs and direct sun!
Pump must be installed on a stable support at a max 1,5 mt height from tank’s bottom.
Injection point must be higher than tank to avoid accidental chemical injection.
Otherwise, connect a multifunction valve on delivery pipeline.
INSTALLATION PUMP GUIDELINES
Install the pump
- in a safety place and fixed to the table / wall to avoid vibration problems;
- in an easy accessible place;
- in horizontal position.
Requirements
for product
positioning
10
Use only hoses compatibles with product to dose.
See “Chemical compatibility table” page 31.
If dosing product is not listed please consult full compatibility table or contact
chemical’s manufacturer.
REQUIREMENTS FOR PRODUCT POSITIONING
Only use fasteners of the proper size and material.
Replace all corroded fasteners.
Make sure that all fasteners are properly tightened and that there are no missing
fasteners.
Foot filter / Level
probe
(included only in
some models)
Level probe is assembled with a foot filter that avoid sediments priming probles.
Install level probe on the bottom of the tank.
Connect BNC level probe to the pump BNC input.
Warning: If there is a mixer installed into tank, install a suction lance instead of
level probe / foot filter.
In case of replacement of level probe parts, follow the diagram below.
Fig. 5. Level probe assembling diagram.
STEP 5
STEP 4
INSERT RING AS SHOWN
STEP 3
A CLICK
STEP 2
INSERT FLOATER
INSERT PROBE
WITH N.O. CONTACT
UNTIL TO HEAR
STEP 1
INSERT RING AS SHOWN
12