Essick Hd1409, Ea1407 Owner's Manual

    DUALFANCONSOLE
EVAPORATIVE
R
EAD AND
S
AVE
T
HESE INSTRUCTIONS
®
HUMIDIFIER
(14GALLONSERIES)
USEANDCAREGUIDE
AdjustableHumidistat
EA1407 ; HD1409
Easyfillbottles
FourCasters
Français ………….17 Español ………..…33
TOORDERPARTSANDACCESSORIESCALL1.800.547.3888
1B72673 5/2014 PRINTED IN CHINA
IMPORTANT SAFEGUARDS General Safety Instructions
READ BEFORE USING YOUR HUMIDIFIER
DANGER: means if the safety information is not followed someone will be seriously injured or killed.
WARNING: means if the safety information is not followed someone could be seriously injured or killed.
CAUTION: means if the safety information is not followed someone may be injured.
1. To reduce the risk of fire or shock hazard, this humidifier has a polarized plug (one blade is wider than the other). Plug humidifier directly into a 120V, A.C. electrical outlet. Do not use extension cords. If the plug does not fully fit into the outlet, reverse plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.
2. Keep the electric cord out of traffic areas. To reduce the risk of fire hazard, never put the electric cord under rugs, near heat registers, radiators, stoves or heaters.
3. Always unplug the unit before moving, cleaning or removing the fan assembly section from the humidifier, or whenever it is not in service.
4. Keep the humidifier clean. To reduce the risk of injury, fire or damage to humidifier,
use only cleaners specifically recommended for humidifiers. Never use flammable, combustible or poisonous materials to clean your humidifier
5. Do not put foreign objects inside the humidifier.
6. Do not allow unit to be used as a toy. Close attention is necessary when used by or near children.
7. To reduce the risk of electrical hazard or damage to humidifier, do not tilt, jolt or tip humidifier while unit is running.
8. To reduce the risk of accidental electrical shock, do not touch the cord or controls with wet hands.
9. To reduce the risk of fire, do not use near an open flame such as a candle or other flame source.
WARNING: For your own safety, do not use humidifier if any parts are damaged
or missing. WARNING: To reduce risk of fire, electric shock, or injury always unplug before
servicing or cleaning. WARNING: To reduce the risk of fire or shock hazard, do not pour or spill water
into control or motor area. If controls get wet, let them dry completely and have unit checked by authorized service personnel before plugging in.
2
INTRODUCTION
Your new humidifier adds invisible moisture to your home by moving dry inlet air through a saturated wick. As air moves through the wick, the water evaporates into the air, leaving behind any white dust, minerals, or dissolved and suspended solids in the wick. Because the water is evaporated, there is just clean and invisible moist air.
As the evaporative wick traps accumulated minerals from the water, its ability to absorb and evaporate water decreases. We recommend changing the wick at the beginning of every season. In hard water areas, more frequent replacement may be necessary to maintain your humidifier’s efficiency.
Use only AIRCARE® or Essick Air® / MoistAIR® brand replacement wicks and chemicals. To order parts, wicks and chemicals call 1-800-547-3888. This series of humidifiers uses wick # HDC12. Only AIRCARE
®
or Essick Air® / MoistAIR® evaporative wicks guarantee
the certified output of your humidifier. Use of other brands of wicks voids the certification of output and may void your warranty.
KNOW YOUR HUMIDIFIER
Description EA1407/HD1409
*Output per 24 hrs 14 gallons/53 Litres Capacity of Each Bottle 2.375 gallons/ 9 Litres
*Sq. ft. coverage
Fan Speeds 3 Auto Fan Speed Yes Replacement Wick HDC12 (Set of 4) Refill Indicator Yes Adjustable Humidistat Yes Auto Shut Off Yes Controls Digital Casters Yes (4) ETL Listed Yes Volts 120 A.C. Hertz 60 Amps (High Speed) 2.88 Watts (High Speed) 165
* Based on an area with average insulation and an 8 foot
ceiling height. ANSI/AHAM HU-1-1997. SEC 8.1 Results may vary.
+3,000 (Tight Const.) 2,900 (Avg. Const.)
3
HOW YOUR HUMIDIFIER WORKS
Dry air is drawn into the humidifier though the back and moisturized as it passes through the evaporative wicks. It is then fanned out into the room.
ASSEMBLY
1. Unpack humidifier from carton. Remove manual.
2. Remove all packaging materials. Some packaging material is located under the
fan assembly. Verify the following items are in the humidifier cabinet.
2 wick assemblies with
4 wicks installed
2 bottles 2 bottle caps and 2 valve caps Float with retainer ring Manual & registration card
CASTERS
3. Turn the emptied cabinet upside down.
4 casters and 2 caster pads
4. Insert each caster stem into one of the
four caster holes manually Do not use tools. The casters should fit snugly and be inserted until the stem shoulder reaches the cabinet surface.
5. Turn the cabinet right side up.
REINSTALLING COMPONENTS
1. Reinstall float.
2. Reinstall wick assemblies into cabinet.
3. Reinstall water bottles
Float
Front
Front
FRO
N
T
FRONT
FRONT
Front
Left
Right
FRONT
Front
FRONT
NOTES ON LOCATION:
In order to get the most effective use from your humidifier, it is important to position the unit where the most humidity is needed or where the moist air will be circulated throughout the house such as near a cold air return. If the unit is positioned close to a window, condensation may form on the window pane. If this occurs, the unit should be repositioned in another location.
Place humidifier on a flat, level surface. Do NOT position the unit directly in front of a hot air duct or radiator. If placing on carpet, use caster pads to ensure level placement.
Due to release of cool, moist air from the humidifier, it is best to direct air away from thermostat and hot air registers. Place the unit on a level surface 2 inches from the wall.
NOTE: The use of a buble level will ensure placement for proper bottle draining.
Front of cabinet
Front caster
Caster pad
Carpet or uneven surface
If positioning on carpet or uneven surface, place caster pads under front casters only to level (if necessary).
4
FILLING
WARNING: Disconnect power before filling, cleaning or servicing unit. Keep grille dry
at all times. WARNING: To reduce the risk of fire or shock hazard, DO NOT pour or spill water into
control or motor area. If controls get wet, let them dry completely and have unit checked by authorized service personnel before plugging in
NOTE: Fill unit with cool, fresh (preferably unsoftened) water. If you only have softened water available in your home, you can use it, but mineral buildup will occur more quickly.
NOTE: On initial fill up, it may take approximately 30 minutes for the wicks to become fully saturated.
CAUTION: Use only EPA Registered Bacteriostat. Under no circumstances should you use Water Treatment products intended for Rotobelt or Ultrasonic humidifiers.
We recommend using AIRCARE when you refill the water reservoir to eliminate bacterial growth. Add bacteriostat according to the instructions on the bottle. Call 1-800-547-3888 to order.
NOTE: The humidifier contains water bottles. The weight of the bottles in the front of the cabinet may cause the front casters to sink deeper into the carpet. If this happens, the water level will be higher towards the front of the humidifier, and lower towards the back. The water level float (located at the rear of the cabinet) may not sense the water so the flashing “F” will be displayed and the unit will not energize. If this happens, the unit will need to be leveled in order for the humidifier to be energized. To level the humidifier, place the included caster pads under the front two casters of the humidifier only.
1. Open the pivoting lid of the humidifier. Remove the water bottles by lifting them straight up and out of the cabinet.
Notice the water bottles are designed as right and left hand units. When refilling the bottles ensure correct placement for proper function.
The water bottles should rest in the front of the cabinet. Each “Side-Fill Cap” must be facing the rear of the unit.
Each water bottle is designed with a “Side-Fill Cap” and bottom valve cap. Before filling each bottle check that the bottle valve cap is on securely.
NOTE: A fill hose, P/N 4400, that attaches to a faucet can be purchased by calling1-800-547-3888.
®
or Essick Air® Bacteriostat Treatment P/N 1970
5
Loading...
+ 11 hidden pages