Essick Ep9800 Owner's Manual

5 (4)

READ AND SAVE THESE INSTRUCTIONS

EVAPORATIVE

HUMIDIFIER

OWNER’S

CARE

&

USE

MANUAL

MODELS:

EP9 500 Nutmeg Pedestal

EP9R 500 Nutmeg Pedestal

with Remote

Digital control

Variable Speed

Automatic Humidistat

Automatic Shutoff

Quiet Setting for Nighttime use

SAVE THE ENVIRONMENT

RECYCLE APPROPRIATE MATERIALS

Patents: 5,037,583; 5,110,511; 5,133,904

Other Patents Pending

French and Spanish Instructions included.

Se incluyen instrucciones En Español y Francés.

Directives en Français et en espagnol compris

1B71976 7/10

IMPORTANT SAFEGUARDS

General Safety Instructions

READ BEFORE USING YOUR HUMIDIFIER

DANGER: means if the safety information is not followed someone will be seriously injured or killed.

WARNING: means if the safety information is not followed someone could be seriously injured or killed.

CAUTION: means if the safety information is not followed someone may be injured.

1.To reduce the risk of fire or shock hazard, this humidifier has a polarized plug (one blade is wider than the other.) Plug humidifier directly into a 120V, A.C. electrical outlet. Do not use extension cords. If the plug does not fully fit

into the outlet, reverse plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.

2.Keep the electric cord out of traffic areas. To reduce the risk of fire hazard, never put the electric cord under rugs, near heat registers, radiators, stoves or heaters.

3.Always unplug the unit before moving, cleaning or removing the fan assembly section from the humidifier, or whenever it is not in service.

4.Keep the humidifier clean.

5.Do not put foreign objects inside the humidifier.

6.Do not allow unit to be used as a toy. Close attention is necessary when used by or near children.

7.Never use your humidifier while any part is missing or damaged in any manner.

8.To reduce the risk of electrical hazard or damage to humidifier, do not tilt, jolt or tip humidifier while unit is running.

9.To reduce the risk of damage to humidifier, unplug when not in use.

10.To reduce the risk of accidental electrical shock, do not touch the cord or controls with wet hands.

11.To reduce the risk of fire, do not use near an open flame such as a candle or other flame source.

12.Note the warning label shown below.

WARNING: To reduce risk of fire, electric shock, or injury always unplug before servicing or cleaning.

CAUTION: If a plant is placed on the pedestal, ensure no water is poured onto the control panel when watering the plant. If water enters the electronic control panel, damage may result. Ensure control panel is entirely dry before use.

WARNING: To reduce the risk of fire or shock hazard, do not pour or spill water into control or motor area. If controls get wet, let them dry completely and have unit checked by authorized service personnel before plugging in.

2

Essick Ep9800 Owner's Manual

Know Your Humidifier

Description

EP9 500/

 

†EP9R 500

*Output per 24 hrs

9 + gallons

Capacity of Unit

3.5 gallons

Sq. ft. coverage

2000

Fan Speeds

Variable (9)

Replacement Wick

No. 1043

Automatic Humidistat

Yes

Controls

Digital (w/ Remote)

ETL Listed

Yes

Volts

120

Hertz

60

Watts

70

3

How Your Humidifier Works

Your new evaporative humidifier is designed to satisfy home humidity requirements through the principle of evaporation of water into the air.

Once the wick becomes saturated, air is drawn in, passes through the wick and moisture is absorbed into the air. All evaporation occurs in the humidifier so any residue remains in the wick. This natural process of evaporation creates no white dust like some other humidifiers.

Dry air is drawn into the humidifier though the back and moisturized as it passes through the evaporative wick. It is then fanned out into the room.

When Outdoor

Recommended

Temperature is:

Indoor Relative

F

C

Humidity (RH) is

-10°

-24°

20%

-18°

25%

10°

-12°

30%

> 20°*

>-6°*

35%

* or higher

IMPORTANT: Water damage may result if condensation starts to form on windows or walls. Humidity SET point should be lowered until condensation no longer forms. We recommend room humidity levels do not exceed 50%.

WARNING:

For your own safety, do not use humidifier if any parts are damaged or missing

CAUTION: Do NOT position the unit directly in front of a hot air duct or radiator. Do NOT place on soft carpet

4

Set Up and Location

1)Unpack humidifier from carton and remove all packaging material from the box.

NOTE: This unit has a natural stone (marble) tile inset. Take care when removing the marble tile from the package, as it is breakable and heavy.

2)Lift up the chassis (upper cabinet) to locate the casters and manual.

3)Place humidifier on a flat level surface. Position the humidifier where the most humidity is needed or where the most air will be circulated throughout the house such as near a cold air return. If the unit is positioned close to a window, condensation may form on the window

pane. If this occurs the unit should be repositioned in another location.

NOTE: Due to release of cool, moist air from humidifier, it is best to direct air away from thermostat and hot air registers, and to position humidifier next to an inside wall. Unit should not be placed where cold air from outside walls or warm air from a hot air register blows directly on it.

3)Place the humidifier at least 2 inches from the wall.

Assembly

CASTERS

1)Lift chassis off of base and set aside.

2)Remove float and wick/wick retainer from base. Turn the empty base upside down. Insert each caster stem into a caster hole on each corner of the humidifier bottom. The casters should fit snugly and be inserted until the stem shoulder reaches the cabinet surface.

3)Turn the base right side up.

EVAPORATIVE WICK

4)Ensure the 1043 Superwick is installed in the two-part wick retainer base in the base of the humidifier

5)Position the chassis over the base frame and press it onto the base firmly until it is in place.

6)Ensure the chassis is placed on the base with the float facing forward.

5

FILLING INFORMATION

7)Open the fill door on the front of the unit. Using a pitcher, carefully pour water into the water fill door.

NOTE: Reservoir holds 3.5 gallons. Do not over-fill unit, as leaks may occur. NOTE: On initial fill up, it will take approximately 20 minutes for the reservoir to fill because the dry wick has to absorb water. Subsequent fillings will take approximately 12 minutes, since the wick is already saturated.

After the filling process is complete, and the wick is saturated, the unit is ready for use.

CAUTION: If a plant is placed on the pedestal, ensure no water is poured onto the control panel when watering the plant. If water enters the electronic control panel, damage may result. If controls get wet, let them dry completely and have unit checked by authorized service personnel before plugging in.

8)Plug cord into wall receptacle. Your humidifier is now ready for use. The humidifier should not be near any heat registers. Place the unit at least TWO inches away from any walls. Unrestricted airflow into the unit will result in the best efficiency and performance.

Controls and Operation

This unit has a digital control panel that allows you to adjust fan speed and humidity level, as well as view information on the status of the unit. The display will also indicate if the optional Remote Control (EP9R 500 only) is in use at the time.

1)The digital controller has a display that provides information on the status of the unit. Depending on which function is being accessed, it displays relative humidity, fan speed, set humidity and indicates when the unit is out of water.

6

FAN SPEED

2) The Speed button controls the variable speed motor. Nine speeds provide precise fan control. Press the power button and select fan speed: F1 through F9 proceeding from low to high speed.

The fan speed will display on the control panel as the speeds are stepped through.

NOTE: When excessive condensation exists, a lower fan speed setting is recommended.

HUMIDITY CONTROL

NOTE: The EP9 500 / EP9R 500 units have an automatic humidistat located on the cord that measures the relative humidity in the room. When the selected humidity level drops 3% below the relative humidity, the humidifier cycles on and off as required to maintain the selected setting.

3) At initial startup the relative humidity of the room will be displayed.

Each successive push of the Humidity Control Button will increase the setting in 5% increments. At 65% set point, the unit will operate continuously.

OTHER INDICATIONS

4)This humidifier has a check filter reminder timed to appear after

720 hours of operation. When the Check Filter (CF) message is displayed, disconnect the power cord and check the condition of the filter. The CF function is reset after plugging the unit back in.

5) When the unit is out of water, a flashing F will display on the display panel.

7

REMOTE CONTROL INSTRUCTIONS (EP9R 500)

If your unit has the remote control, or if you have purchased the remote control, Model 1999, you have the option of controlling your humidifier functions from a distance.

To Turn the Remote on:

With both the humidifier and remote control OFF, Press the I/O button on the remote control once. This turns the humidifier ON and enables the remote control to operate all the functions of the humidifier.

(The humidifier control panel will display EC, for External Control)

Press the respective humidity and Fan Speed buttons to adjust the settings on the remote, just as you would the actual humidifier.

The default setting for temperature readout is Fahrenheit (F). If you prefer degrees Celsius (C), press the I/O button one more time to use that unit of measure.

Pressing the I/O button one more time will turn both the Remote Control and the Humidifier OFF.

If the Humidifier is already on and operating when the I/O button on the remote is pressed, command of the humidifier transfers to the Remote, and reverts to the settings last used with the remote. You can readjust the settings as desired.

If the controls on the humidifier are used while the Remote Control is in command, control will revert to the humidifier, and the settings will revert to those last used on the humidifier control panel. The remote control will remain on until turned off.

USING THE REMOTE CONTROL

When the remote is in control, the display on the humidifier will read EC (for External Control).

The humidity and speed buttons operate the same way as their counterparts on the unit.

The fan speed and humidity setting will display on the control panel as you adjust them.

The default measure for temperature is Fahrenheit (°F), but pressing the I/O button a second time will change to Celsius (°C)

Periodically the remote performs a frequency check and will be unresponsive to input. Wait 5 seconds and try your input again.

8

Wick Replacement

The EP9 500 / EP9R 500 use the 1043 Super Wick. Always use the original Essick brand wick to maintain your unit and maintain your warranty.

1)First, remove any items on top of the pedestal and remove the natural stone tile and place in a safe location.

2)Lift chassis up off the base to reveal the wick, wick retainer and float.

3)Remove the wick and retainer assembly. Separate the two-part wick retainer.

4)Remove the old wick, drain excess water and discard.

5)Place new Essick 1043 wick into smaller side of the wick retainer and snap the larger, back section into place.

6)Then place the assembly into the base, aligning it with the built-in guides.

9

Care and Maintenance

CAUTION: Disconnect power before filling, cleaning or servicing unit. Keep grille dry at all times.

Cleaning your humidifier regularly helps eliminate odors and bacterial and fungal growth. Ordinary household bleach is a good disinfectant and can be used to wipe out the humidifier base after cleaning. We recommend cleaning your humidifier at least once every two weeks to maintain optimum environmental conditions for your home.

We also recommend using Essick Air Bacteriostat Treatment each time you refill your humidifier to eliminate bacterial growth. Add bacteriostat according to the instructions on the bottle. Please call 1-800-547-3888 to order Bacteriostat Treatment reference part number 1970.

1)Remove any items from the pedestal top. Remove natural stone tile and place in safe location. Turn off unit completely and unplug from outlet.

2)Lift off chassis and set aside.

3)Carry base to cleaning basin. Lift wick and retainers from the base allowing the water to drain. Rinse wick under fresh water only. Do not use soap, detergent, or any other cleaners on the wick. Leave in sink to drain.

REMOVING SCALE

4)Empty the water from the base. Fill base with water and add 8 oz. (1 cup) of white vinegar. Let stand 20 minutes. Then empty solution.

5)Dampen a soft cloth with white vinegar and wipe out base to remove scale. Rinse the entire water reservoir area thoroughly with fresh water to remove scale and cleaning solution before disinfecting.

DISINFECTING UNIT

6)Fill base to MAX FILL line with water and add 1 teaspoon of bleach. Wipe interior surfaces with this solution. Let solution stay for 20 minutes, then rinse with water until bleach smell is gone. Dry with clean cloth. The outside of the unit may be wiped down with a soft cloth dampened with fresh water.

7)Replace the chassis onto the base and refill unit through the pour-fill spout.

SUMMER STORAGE

Although the pedestal humidifier is attractive enough to be kept out year round, if you choose to put the unit away for the summer, ensure proper care is taken to protect the humidifier during storage. We recommend wrapping the marble tile in a towel or blanket to protect it during storage. We also recommend storing the optional remote control (with batteries removed) with the humidifier for easy access when the humidifier is used again.

Clean unit as outlined in Care & Maintenance section.

1)Discard used wick and any water in the base and allow to dry thoroughly before storage. Do not store with water inside the base.

2)Do not store unit in an attic or other high-temperature area.

3)Install new filter at beginning of season.

10

Parts List for EP9 500/EP9R 500

10

Replacement Parts Available For Purchase

Key No.

Description

Part Number

1

Deflector

1B71973

2

Fill Door

1B71970

3

Float

1B71971

4

Float Retainer

1B71972

5

Casters (4)

1B5460070

6

Wick Retainer - Front

1B71974

7

Wick

1043

8

Wick Retainer - Back

1B71975

9

12” x 12” x 3/8” Natural Stone Tile

1B71984

10

Remote Control

7V1999

--

Owner’s Manual (Not pictured)

1B71976

Parts and accessories may be ordered by calling 1-800-547-3888. Always order by part number, not key no. Please have model number of humidifier available when calling.