OWNERS CARE & USE MANUAL
General Safety Instructions
READ BEFORE USING YOUR HUMIDIFIER
DANGER: means if the safety information is not followed someone will be seriously injured or killed.
WARNING: means if the safety information is not followed someone could be seriously injured or killed.
CAUTION: means if the safety information is not followed someone may be injured.
1. To reduce the risk of fire or shock hazard, this humidifier has a polarized plug (one blade is wider than the other.) Plug humidifier directly into a 120V, A.C. electrical outlet. Do not use extension cords. If the plug does not fully fit into the outlet, reverse plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.
2. Keep the electric cord out of traffic areas. To reduce the risk of fire hazard, never put the electric cord under rugs, near heat registers, radiators, stoves or heaters.
3. Always unplug the unit before moving, cleaning or removing the fan assembly section from the humidifier, or whenever it is not in service.
4. Keep the humidifier clean.
5. Do not put foreign objects inside the humidifier.
6. Do not allow unit to be used as a toy. Close attention is necessary when used by or near children.
7. Never use your humidifier while any part is missing or damaged in any manner.
8. To reduce the risk of electrical hazard or damage to humidifier, do not tilt, jolt or tip humidifier while unit is running.
9. To reduce the risk of damage to humidifier, unplug when not in use.
10. To reduce the risk of accidental electrical shock, do not touch the cord or controls with wet hands.
11. To reduce the risk of fire, do not use near an open flame such as a candle or other flame source.
12. Note the warning label shown below.
WARNING: To reduce risk of fire, electric shock, or injury always unplug before servicing or cleaning.
INTRODUCTION
Your Essick Air evaporative humidifier adds invisible moisture to your home by moving dry inlet air through a saturated wick. As air moves through the wick, the water evaporates into the air, leaving behind any white dust, minerals, or dissolved and suspended solids. Because the water is evaporated, the result is just clean, moist air.
As the evaporative wick traps accumulated minerals from the water, its ability to absorb and evaporate water decreases. We recommend changing the wick at the beginning of every season. In hard water areas, more frequent replacement may be necessary to maintain your humidifier’s efficiency.
Use only Essick Air brand replacement wicks and chemicals. To order parts, wicks and chemicals call 1-800-547-3888. The ED11 Series humidifiers use Essick Air wick # 1041. Only the Essick Air evaporative wick guarantees the certified output of your humidifier. Use of wicks other than Essick Air brand will void your warranty as well as the certification of output and may reduce the output of your humidifier.
2
KNOW YOUR HUMIDIFIER
Description
ED11 Series
*Output per 24 hrs
11 gallons
Capacity of Reservoir
2.5 Gallons
Sq. ft. coverage
2,300
Fan Speeds
Variable
Replacement Wick
1041
Air Purifying Filter (Optional)
1051
Auto Humidistat
Yes
Controls
Digital
ETL Listed
Yes
Volts
120
Hertz
60
Watts
160
Accessories Available For Purchase
Description
Part Number
Humidifier Wick
1041
Air Purifying Filter (Optional)
1051
* Based on an area with average insulation and an 8’ ceiling height.
Accessories may be ordered by calling 1-800-547-3888. Please have model and serial number of humidifier available when calling.
3
HOW YOUR HUMIDIFIER WORKS
Dry air is drawn into the humidifier through the back and moisturized as it passes through the evaporative wick. It is then fanned out into the room.
1. Chassis/Power Pack (motor and fan assembly)
2. Evaporative wick
3. Water reservoir
4. Dry room air intake
5. Moist air output
CAUTION: Do NOT position the unit directly in front of a hot air duct or radiator. Do NOT place on soft carpet.
NOTE: Humidifier must be level for proper operation, and to prevent leakage. ASSEMBLY, CONTROLS & OPERATION
1) Remove the packing inserts from the top of the humidifier.
2) Lift off the chassis/power pack and then remove the humidifier tank/cabinet from the carton.
3) Remove any wrapping from the evaporative wick and all of the remaining packaging materials from the cabinet. Check to see that you have all of the following items removed from the boxes accessory kit and cabinet before discarding the packaging:
● Caster kit ● Float (Styrofoam)/Float rod ● Retainer (key for float rod)
● Reservoir float assembly ● Wick ● Manual
CASTERS
4) Turn the emptied cabinet upside down. Insert each caster stem into the four caster holes on each corner of the humidifier bottom. The casters should fit snugly and be inserted until the stem shoulder reaches the cabinet surface. Turn the cabinet right side up.
FLOAT AND WICK INSTALLATION
5) Before installing the wick, install the float rod by placing the white Styrofoam portion into the recess in the bottom of the cabinet. Then place the float retainer loop over the float rod spindle. Slide the clip end of the retainer onto the extension molded into the plastic ledge until it locks into place. See illustration at right.
6) Install the 1041 wick into the unit with the mounting rib on the top edge that hooks over a rib at the back inside of the cabinet. See inset on illustration at left.
4
Rear of Unit
NOTE: Ensure pre-installed float valve
assembly is positioned correctly and securely in place. Vibrations in shipping may have loosened them. The valve should work up and down, and nut should fit snug against the reservoir wall. Always check for leaks around valve assembly, especially after moving the unit.
CHASSIS/POWER PACK
7) Place the chassis/power pack unit into the cabinet, so it fits without tipping or rocking, ensuring the float rod fits in the pocket of the chassis.
CAUTION: Disconnect power before filling, cleaning or servicing unit. Keep grille dry at all times.
NOTE: Chassis must be in place before filling. IMPORTANT FILLING INFORMATION
8) The water fill compartment door is located on the left
side of the unit. The latch is released by pressing on the fill door. It will pop open.
9) Fill by carefully pouring cool tap water or bottled
distilled water from a pitcher/container or using a fill hose attached to a faucet. Do not use warm water as this might cause damage or leaking from the unit.
10) When the tank is filled for the first time and the wick
is still dry, it will take approximately 30 minutes for the wick to absorb the water from the reservoir. After this initial saturation, the tank should be refilled again to obtain maximum running time.
11) If you only have softened water available in your home, you can use it, but you
will notice a buildup of minerals on the wick much sooner. The tank holds 2.5 gallons. When filling, be careful not to overfill.
AIR CLEANING FILTER (OPTIONAL)
12) The AirCare filter has four tangs that
engage into four keyhole slots that mount the AirCare® filter onto the outside of the back of the cabinet.
NOTE: We recommend using Essick Air Bacteriostat treatment part # 1970 when you refill the tank to eliminate bacterial growth. Add bacteriostat according to the instructions on the bottle.
NOTE: Overfilling will result in water damage.
5
OPERATION
The digital controller has a display that provides information on the status of the unit. Depending on which function is being accessed, it displays relative humidity, fan speed, set humidity and indicates when the unit is out of water.
Note: Place the unit at least FOUR inches away from any walls or curtains. Unrestricted airflow into the unit will result in the best efficiency and performance.
1.
2.
3.
1. Plug cord into wall receptacle. Your humidifier is now ready for use.
FAN SPEED
2. Press the power button and select fan speed: F1 through F9 proceeding from
low to high speed.
NOTE: When excessive condensation exists, a lower speed setting is recommended.
HUMIDITY CONTROL
NOTE: Both models have an automatic humidistat that cycles the humidifier on and
off as required to maintain the selected setting.
3. At initial startup the relative humidity of the room will be displayed.
4. Each time you push the Humidity Control Button the setting will increase in 5% increments. At 65% set point, the unit will operate continuously.
5. The control will display a flashing “F” when the water reservoir is empty. When the unit is completely out of water, the motor will shut off.
6. This humidifier has a check filter reminder timed to appear after 720 hours of operation. When the Check Filter (CF) message is displayed, disconnect the power cord and check the condition of the filter. The CF function is reset after plugging the unit back in.
OPTIONAL AIRCARE® FILTER
The first stage of the air filter is a high-efficiency, electrostatically-charged filter media which traps dust, pollen, and airborne pollutants. The second stage is an activated carbon media which absorbs odors from cooking, pets, or tobacco smoke. We recommend replacing the AirCare® filter at least once a year and more often if necessary. When the white filter media is coated with a layer of dust and dirt, it is time to replace the AirCare® filter. The certified water output of your humidifier will be reduced when using the AirCare® filter. AirCare® filters are optional and are not required for normal operation of the humidifier. AirCare® is registered
trademark of Essick Air Products.
6
CARE AND MAINTENANCE
Cleaning your humidifier regularly helps eliminate odors and bacterial and fungal growth. Ordinary household bleach is a good disinfectant and can be
used to wipe out the humidifier base and reservoir after cleaning. We recommend cleaning your humidifier at least once every two weeks to
maintain optimum environmental conditions for your home.
We also recommend using Essick Air Bacteriostat Treatment each time you refill your humidifier to eliminate bacterial growth. Add bacteriostat
according to the instructions on the bottle. Please call 1-800-547-3888 to order Bacteriostat Treatment reference part #1970.
1) Turn off unit completely and unplug from outlet.
2) Lift out the chassis.
3) Take reservoir to cleaning basin. Lift wick from the reservoir allowing the water to drain. Rinse the wick under fresh water only. Do not use soap, detergent, or any other cleaners on the wick. Leave in sink to drain.
REMOVING SCALE
4) Empty the water from the reservoir. Fill reservoir ½ full with water and add 8 oz. (1 cup) of white vinegar. Let stand 20 minutes. Then empty solution.
5) Dampen a soft cloth with white vinegar and wipe out reservoir to remove scale. Rinse the reservoir thoroughly with fresh water to remove scale and cleaning solution before disinfecting.
DISINFECTING UNIT
6) Fill the reservoir ½ full with water and add 1 teaspoon of bleach. Wet all surfaces on cabinet, then let solution stay for 20 minutes then rinse with water until bleach smell is gone. Dry with clean cloth. The outside of the unit may be wiped down with a soft cloth dampened with fresh water.
7) Refill unit and re-assemble per ASSEMBLY instructions.
SUMMER STORAGE
1) Clean unit as outlined in Care & Maintenance section.
2) Discard used wick and any water in the reservoir and allow unit to dry
thoroughly before storage. Do not store with water inside reservoir.
3) Do not store unit in an attic or other high-temperature area, as damage will
occur.
4) Install new filter at beginning of season.
7
ESSICK AIR PRODUCTS
HUMIDIFIER WARRANTY POLICY
EFFECTIVE APRIL 1, 2010
SALES RECEIPT REQUIRED AS PROOF OF PURCHASE
FOR ALL WARRANTY CLAIMS.
This product is warranted against defects in workmanship and materials as listed below: One year from the date of sale on factory installed components. Two years from the date of sale on motor. Thirty (30) days on replacement components. This warranty does not apply to filters or wicks which are customer replaceable parts. This warranty applies only to the original purchaser of the product when it is purchased from a
reputable retailer/dealer. This warranty does not apply to damage from accident, misuse, alterations, unauthorized repairs,
unauthorized use, mishandling, unreasonable use, abuse, including failure to perform reasonable maintenance, normal wear and tear, nor where the connected voltage is more than 5% above the nameplate voltage, nor to the equipment or products being improperly installed or wired or maintained in violation of this Owner’s Manual.
Alterations include the substitution of name brand components including, but not limited to wicks and bacteria treatment.
THIS PRODUCT IS NOT INTENDED FOR COMMERCIAL USE. THIS IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY MANUFACTURER WITH RESPECT TO THE PRODUCTS AND, TO THE MAXIMUM EXTENT PERMITTED BY LAW, IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES AND CONDITIONS, EXPRESS OR IMPLIED, ARISING BY OPERATION OF LAW OR OTHERWISE. INCLUDING WITHOUT LIMITATION, MERCHANTABILITY AND/OR FITNESS FOR A PARTICULAR PURPOSE.
No employee, agent, dealer or other person is authorized to give any warranties or conditions on behalf of the manufacturer. The customer shall be responsible for all costs incurred in the removal or reinstallation and shipping of the product for repairs.
Within the limitations of this warranty, purchaser with inoperative units should contact customer service @ 800-547-3888 for paperwork and instructions on the return of the unit for repair.
Notice:This warranty will be null & void if purchaser attempts to repair or replace any parts which are mechanical or electrical.
A copy of the sales receipt is required before authorization to return a unit for repair is approved. The manufacturer will repair or replace the product, at its discretion, with return freight paid by the manufacturer. It is agreed that such repair or replacement is the exclusive remedy available from the manufacturer and that TO THE MAXIMUM EXTENT PERMITTED BY LAW, THE MANUFACTURER IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGE OR LOSS OF PROFITS OR REVENUES.
The warranty gives the customer specific legal rights, and the customer may also have other rights which vary from province to province, or state to state.
8