Essick BFC2200 Instruction Manual

Read & Save This
Instuction Manual
Lea y mantenga este
manual de instrucción
Box Fan
Evaporative
Cooler Model
BFC2200
FROM
THE ESSICK
FAMILY
E N G
L
I
S H
Enfriadera
con
Ventilador
de Caja
BFC2200
DE LA
FAMILIA
ESSICK
E S P
1
A
1
˜
N O L
ESSICK AIR
5800 Murray Street
Little Rock, AR 72209
www.essickair.com
71096/E-018-December 2003
ESSICK AIR
5800 Murray Street
E N G L
2
I
S H
71096/E-018-December 2003
Little Rock, AR 72209
www.essickair.com
E S P A
2
˜
N O L
WARNING: To reduce the risk of fire or electrical shock, do not use this fan with any solid state speed control device.
Unpack your Essick cooler and select the area you wish to cool. Evaporative coolers work best near a partially opened window to draw in fresh air. An equal amount of air should be discharged out of the room to dispel heat and humidity. The cooler can be placed on the floor or on a table. Pour water into the water trough located in the lower portion of the back grille. The reservoir holds 3 1/4 gallons of water. The level can be seen through the front grille. DO NOT OVER FILL. Water will leak out and could cause water damage to the surrounding area. If the reservoir runs dry, it will not harm the pump.
When transporting the unit to a different location, be very careful not to spill the water. It is best to re-locate the cooler, and then add water. Plug the electrical cord into a 115-120 volt grounded outlet. You may operate your cooler on one of three speeds: low, medium or high. Turn the switch knob clockwise to activate the pump and fan. This will cool the air. Turn the switch counterclockwise to operate the cooler as a fan only (pump will be off).
When you operate your cooler without the water circulating, it functions as a fan to circulate air.
ENGLISH
3
CAUTION: Always unplug the cooler before attempting service of any kind.
1.
The pump hose may have worked loose. Check the connection at the pump and at the water tube located in the back grille assembly. Reconnection of pump hose is necessary.
2.
The water tube may be blocked. Remove the tube and clean it out to make sure water holes are clear.
3.
The pump or switch may be defective. Replace pump or switch, if necessary.
1.
Check the electrical outlet to verify it provides 115-volt power. Check fuse or breaker to ensure no fuses are blown or breaker switches thrown.
2.
The fan switch or motor may be defective. Replace switch or motor, if necessary.
ENGLISH
5
CAUTION: To reduce the risk of fire, always unplug the cooler before attempting service of any kind.
The motor does not require oil or lubrication. It is permanently lubricated at the factory.
The pump does not require oil or lubrication. Clean any debris under the pump in the inlet area.
The filter should be replaced each season, if it becomes dirty or clogged.
Drain and clean the water tank. To drain, disconnect the clear hose from the black tube in the back grille. Turn unit on “COOL” and pump out most of the water. Wipe dry and clean with a towel. Before reattaching the back grille, reconnect the clear hose to the black water tube.
Use spray paint on the interior of the cabinet to touch up scratches or dings, if necessary.
This warranty is extended to the original purchaser only. It does not cover damages incurred during shipping or through accident, neglect, or abuse by the owner. Essick Air Products, Inc. does not authorize any person or representative to assume any other or different liability in connection with this cooler.
All original parts provided by Essick Air Products, Inc. are warranted against defects in material or factory workmanship for one year.
Essick Air Products, Inc. is not responsible for incidental or consequential damage resulting from any malfunction.
Essick Air Products, Inc. is not responsible for any damage occurring from the use of water softeners, chemicals, materials that de-scale, or if a higher horsepower motor than what Essick Air Products, Inc. recommends is used in the unit.
Essick Air Products, Inc. is not responsible for the cost of service calls to diagnose cause of trouble, or labor charge to repair and/or replace parts.
Contact the Dealer where you purchased the evaporative cooler. If for any reason you are not satisfied with the
E N G L
4
I S H
response from the Dealer, contact the Customer Service Department: Essick Air Products Inc. 5800 Murray Street, Little Rock, Arkansas 72209. 1-501-562-1094.