ESRTERFW
Wireless Digital
Room Thermostat
Installation Instructions

Thank you for choosing ESi Controls.
All our products are tested in the UK so we are
confident this product will reach you in perfect
condition and give you many years of service.
However, for additional peace of mind, we
recommend you register your product online at
www.esicontrols.co.uk/warranty for your
extended warranty.
2

3
Installation Instructions
Technical Data 6
Installation Instructions
Installation Safety Instructions 7
Maintenance 7
Safety Notice 8
Fitting the Room Thermostat 8
Fitting the Receiver 9
Commissioning/ Configuring 9
Wiring Diagram 10
DIP Switch Settings - Heating 11
Heating Mode 11
Receiver Manual Override 12
Contents

5
Installation Instructions

6
Wireless Digital Room Thermostat with TPI
Fixing Easy Fit Back Plate
Sensing Element Electronic
Power Supply 230VAC, 50Hz
Switch Action 3(1)A 230VAC
Temperature Setting Range 5°C to 30°C
Current rating Maxiumum 3(1)Amp
Terminal Differential <0.6°C at 4°/hour
Switch Type SPDT
Dimensions L: 85mm x H: 85mm x D: 35mm
Complies with
EN60730-1, EN60730-2.7,
EMC Directive 2004/108/EC,
LVD Directive 2006/95/EC
Receiver
Fixing Easy Fit Back Plate
Power Supply Voltage 230VAC, 50Hz
Power Consumption 6W
Contact Type
6 (2)A. 230VAC SPDT (Volt Free
changeover contacts)
Plastic Thermoplastic, flame retardant
Protection Rating IP30
Dimensions
135mm(L) x 90mm(W)
x 33mm(D)
Complies with:
EN60730-1 EN 60730-2.7,
EMC Directive 2004/108/EC,
LVD Directive 2006/95/EC
Technical data

7
The unit must be installed by a suitably qualified person in
accordance with the latest IEE Wiring Regulations.
Isolate mains supply before commencing installation. Please
read all instructions before proceeding.
Ensure that the fixed wiring connections to the mains supply
is via a fuse rated at not more than 6 amps and class ‘A’
switch having a contact separation of a minimum of 3mm
in all poles. The recommended cable sizes are 1.0mm sqr or
1.5mm sqr. No earth connection is required as the product is
double insulated but ensure continuity of earth throughout
the system.
Maintenance
Always isolate the mains supply before commencing any
work, servicing or maintenance on the system. And please
read all instructions before proceeding.
Arrange for an annual maintenance and inspection schedule
to be carried out by a competent person on every part of the
heating and hot water system.
Installation Safety Instructions

8
Safety Notice
WARNING!
Always isolate the AC mains supply before installing.
this product must be fitted by a qualified person, and
installation must comply with the guidance provided in
the current editions of BS767 (IEE wiring regulations)
and part “P” of the building regulations.
1.5m
Fitting the Room Thermostat
The ideal position to locate the Programmable Room
Thermostat is about 1.5m above floor level, in a location
where the thermostat is accessible, reasonably lit and free
from extremes of temperature and draughts. Do not position
the thermostat near sources of heat, such as radiators lights,
TV, direct sunlight or on an outside wall.
Installation
1. Loosen the screws on the back-plate and remove from
the Unit.
2. If required, fix the back-plate, terminals at the top,
either direct onto a flat wall using wall plugs and screws
or on a flush mounting single conduit box.

9
3. Insert the AA batteries provided and replace the front
cover of the thermostat.
Fitting the Receiver
Installation
1. Loosen the screws on the back-plate and remove from
the Unit.
2. Fix the back-plate, terminals at the top, either direct
onto a flat wall using wall plugs and screws or on a flush
mounting single conduit box. Route the wires through
the back of the wall plate and fit the wires to the wallplate in accordance with the relevant diagram and in
accordance with I.E.E. regulations.
3. Fit the Unit onto back-plate, and tighten the screws.
Ensure an appropriate fuse is fitted to the circuit before
reconnecting to the mains supply.
Commissioning/Configuring
1. If the receiver and thermostat have been supplied as
a kit, the units have already been paired in the factory
and no pairing is needed.
2. Power up the receiver and both lights should come on
for a few seconds.
3. Press and hold M/A (Manual/Auto) button
1
(See page
10) for approximately 10 seconds until the MANUAL
light
2
(See page 10) begins to flash (green).
4. Insert batteries in the thermostat, turn dial up to 5 and
remove dial.
5. Press and hold the black button until the receiver light
goes off.
6. To check it is paired, turn the thermostat above room

10
temperature and check that the red manual button (on
the receiver) lights up.
7. If unsuccessful, leave the unit powered on for 5 minutes
and repeat the steps above.
M/A MANUAL
1 2
1.0-2.5mm
2
6mm MAX
N L 1 2 3 4
COM N/O N/C
Fused Main
Supply
N.B. Volt free contacts.
Wiring Diagram
Room Thermostat Receiver

11
Terminal Identifier Description
N Neutral Neutral
L Live Live Feed (230V AC)
1 COM
Linked Live Feed (230V AC Heating
Applications Only)
2 N/O Normally open
3 N/C Normally closed (NC)
DIP Switch Settings - Heating
Heating Mode
Option to switch to:
1. Chronopropportional (Chrono)
2. 3 or 6 cycles (Chrono on only)
3. °F or °C
HEAT
COMP DELAY (TPI) OFF COMP DELAY (TPI) ON
6 CYCLES 3 CYCLES
°F °C

12
Receiver Manual Override
It is possible to operate the receiver manually. This may be
necessary where, for example, the batteries in the Thermostat
(Transmitter) are depleted and therefore the heating cannot
turn on or off.
To engage the manual override, press the MANUAL button
2
(See page 10) on the receiver, which will then light up with a
green background.
After 2-3 seconds, press the M/A button
1
(See page 10),
which may be ON (red background) or OFF. This will manually
override the status of the receiver. If ON, the heating will turn
OFF (M/A red light goes off). If OFF, the heating will turn ON
(M/A red light comes on).
N.B. It is important to remember that the automatic control
of the receiver is now off and the receiver will only
respond to manual operations.
To return to automatic mode, press the M/A button
1
(with or
without the red light on) and then press MANUAL button
2
(See page 10). The receiver should now be back in automatic
mode, recieving commands from the thermostat.

14
We are continuously developing our products to
bring you the very latest in energy saving technology
and simplicity. However, should you have any questions
setting up your controls please email us at
sales@esicontrols.co.uk or for technical queries call
us on our dedicated technical helpline 07539 117468.

15
WARNING: Interference with sealed parts renders the
guarantee void.
In the interests of continuous product improvement we reserve
the right to alter designs, specifications and materials without
prior notice and cannot accept liability for errors.

Version 6.10.2
© ESi Controls Limited 2017