This document outlines the mechanical repairs that should be made in an attempt to fix the common failures that are seen in the
field. To gain a complete understanding of how to test and repair a unit, this document should be used in conjunction with the Test
Instructions, Mechanical and the Working Instructions, Mechanical.
NOTE! A unit should always be inspected for liquid damage and flashed with latest software before using the
Mechanical Trouble Shooting Guide. Refer to the Mechanical Test Instructions for details regarding upgrading
software.
NOTE! If all of the repair actions listed in this document for addressing a problem have been performed and a unit still
is not working, handle the unit according to your local Sony Ericsson Representative.
The service menu will be accessed with the following key combination. Use the joystick.
⇒*⇐⇐*⇐*
The service menu options are:
Service info
Service Settings
Service tests
Text labels
Under the “Service tests” option, the phone’s software has a built in service functionality that allows you to test some of
the phones functions. It looks like this:
Main display
LED/illumination
Keyboard
Speaker
Earphone
Microphone
Vibrator
Camera
Accelerometer (W580 only)
Memory Stick
FM Radio (W580 only)
Real time clock
Total call time
Security
NOTE: Different names may occur depending on language setting and customization.
A phone that is damaged due to misuse is not covered by warranty. This section shows many of the signs of misuse that
are seen in the field. Please refer to local directives on how a phone that appears to be damaged due to misuse should
be handled.
Below are some examples of damage due to misuse that are not covered by warranty.
Front window broken due to
misuse.
LCD cracked due to drop.Clear scratches Mark after drop
Corrosion components on the PCB. Corrosion components on the PCB. Components damaged by liquid System connector damaged by liquid
Before any tests are performed, an inspection of the liquid intrusion indicator should be made. If the liquid intrusion
indicator is red, this is an indication of possible liquid exposure. If the liquid intrusion indicator suggests liquid exposure,
please consult your local SEMC representative for handling instructions.
Location of the liquid intrusion indicator
The following pictures show the difference between an indicator that has been in contact with liquid and one that has not.
Check whether the phone vibrates
when you press the power key and
whether the navigation keypad
illuminates 15 to 20 seconds after the
phone vibrates
Inspect battery connector
Inspect the power key and the power
switch
If the issue is still not resolvedÆ
Repair Action
If activation of the vibrator and
illumination of the navigation keypad are
detected, refer to the “Display Problems”
section
• If dirty or oxidized, clean the
connector’s contact pins
• If adhesive is detected on the contact
pins, use an eraser to rub off the
adhesive
• If damaged, send to an electrical level
repair location
• If debris is detected around the
power key or between the power key
and the power switch, clean the
power key, the power switch and the
surrounding area
• If the power key is damaged, replace
it
• If the power switch is damaged, send
to an electrical level repair location