Page 2
Components
AB C D
1
2
8x
3
4
5
1x
4x
2x
75-100mm
8x
1/4-20 x 1/2" set screw
M4 x 10mm
ST6.3 x 50 mm
8x
2x
8x
8-32 x 5/16"
2x
4x
8x
1/8"
8x
#8-32 x 1/4"
4x
ST6.3 x 50 mm
3/32"
2x
8x
M4 x 10mm
5
8x
M6 x 70mm
Tools Needed
See Wall Mounting Options for additional tools needed for your type of wall installation.
2
1
Determine Ergonomic Mounting HeightDetermine Ergonomic Mounting Height
1
Set Your Workstation to Work For YOU!
Height Position top of screen slightly below eye level. Position keyboard at about elbow height with wrists fl at. Distance Position screen an arm's length from face—at least 20” (508mm). Position keyboard close enough to create a 90˚ angle in elbow. Angle Tilt screen to eliminate glare. Tilt the keyboard back 10° so that your wrists remain fl at.
8x
1/4-20 x 2"
Learn more about ergonomic computer use at:
www.computingcomfort.org
8x
M6
1/2"
1/2"
2 of 9
To Reduce Fatigue Breathe - Breathe deeply through your nose. Blink - Blink often to avoid dry eyes. Break • 2 to 3 minutes every 20 minutes
• 15 to 20 minutes every 2 hours.
888-61-113-G-00 rev.B • 10/15
Page 3
8“
(203mm)
1“
(25mm)
2“
(51mm)
0.5“
(13mm)
(25mm)
5“
(127mm)
0.85
(22mm
8“
(203mm)
(203mm)
Wall Mounting Options
2
Wood
WARNING: Ensure that the wall structure is capable of supporting four times the total weight of mounted equipment. Mounting to wall surfaces that do not meet this criteria may result in an unstable, unsafe condition which could lead to personal injury and/or property damage. Consult a construction professional if you have any doubt about what this means in regard to your particular application.
4x
ST6.3 x 50 mm
Ø 3/16" (5 mm)
Stud Finder
4
Studs ≥ 25 gauge steel
Hollow Wall
≥ 5/8”
4x
ST6.3 x 50 mm
Ø 3/16" (5 mm)
Stud Finder
4
8x
1/4-20 x 2"
8x
Sheetrock
Ø 1/2" (13 mm)
5
Requires minimum material thickness of 5/8” (16 mm).
888-61-113-G-00 rev.B • 10/15
Concrete
8x
8x
Ø 3/8" (10 mm)
8x
M6
M6 x 70mm
10mm
6
3 of 9
Page 4
Attach to Wall
3
Wood
Studs ≥ 25 gauge steel
a
d
Stud Finder
Ø 3/16" (5 mm)
e
c b
Wood
4x
ST6.3 x 50 mm
Studs ≥ 25 gauge steel
4x
ST6.3 x 50 mm
NOTE: Fasteners may unwind due to vibration caused by movement of mounting solution over time. Inspect mounting solution for loose fasteners on a routine basis. If desired, apply a light duty thread locking adhesive to fasteners before installation to prevent back-out.
4 of 9
4
888-61-113-G-00 rev.B • 10/15
7
Page 5
Attach to Wall
3
a
b
Ø 1/2" (13 mm)
Hollow Wall
≥ 5/8”
Sheetrock
c
d
8x
1. Push anchor plate into hole.
2. Pull loop back so plate opens  at against inside surface of wall.
3. Push collar into hole.
4. Snap o loop.
234
8x
1/4-20 x 2"
NOTE: Fasteners may unwind due to vibration caused by movement of mounting solution over time. Inspect mounting solution for loose fasteners on a routine basis. If desired, apply a light duty thread locking adhesive to fasteners before installation to prevent back-out.
888-61-113-G-00 rev.B • 10/15
4
7
5 of 9
Page 6
Attach to Wall
3
a
b
Ø 3/8" (10 mm)
Concrete
3-1/8" (80 mm)
WARNING: Mounting holes must be at least 3-1/8” (80mm) deep and must be located within solid con­crete, not mortar or covering material. If you drill into an area of concrete that is not solid,
reposition mounting holes until both anchors can be fully inserted into solid concrete!
c
d
8x
8x
8x
M6 x 70mm
123
WARNING:
Anchors that are not fully set in solid concrete will not
support the applied load resulting in an unstable, unsafe
condition which could lead to personal injury and/or prop-
erty damage. Consult a construction professional if you
have any doubt about what this means in regard to your
particular situation.
CAUTION: Make sure the wall mount bracket is level,  ush and
snug to the wall surface. DO NOT OVERTIGHTEN THE BOLTS.
M6
10mm
NOTE: Fasteners may unwind due to vibration caused by movement of mounting solution over time. Inspect mounting solution for loose fasteners on a routine basis. If desired, apply a light duty thread locking adhesive to fasteners before installation to prevent back-out.
6 of 9
4
888-61-113-G-00 rev.B • 10/15
7
Page 7
Attach Pivots to Brackets
4
a b
4x
c
1/2"
1/2"
Attach Displays
5
1/4-20 x 1/2" set screw
d e
3/32"
4x
8-32 x 5/16"
1/2"
1/2"
4x
M4 x 10 mm
75 x 75mm
100 x 100mm
3/32"
4x
#8-32 x 1/4"
a
b
4x
M4 x 10 mm
888-61-113-G-00 rev.B • 10/15
7 of 9
Page 8
Attach Displays to Wall Bracket
6
a
b
1/8"
7
Range of Motion
This product is designed to adjust quickly and easily according to your needs – refer to following steps for adjustment.
Adjust Tilt – Forward and Backward
Tilt – Forward and Backward
a
Rotate - Portrait/Landscape
b
1/2"
1/2"
If it does not stay in place or movement is sti , tension needs adjustment. Adjust until motion is equal.
Increase Friction
If this product moves too easily, then you'll need to increase friction:
Decrease Friction
If this product is too diffi cult to move, then you'll need to decrease friction:
Adjust Rotate – Portrait/Landscape
If it does not stay in place or movement is sti , tension needs adjustment. Adjust until motion is equal.
8 of 9
Increase Friction
If this product moves too easily, then you'll need to increase friction:
Decrease Friction
If this product is too diffi cult to move, then you'll need to decrease friction:
1/2"
888-61-113-G-00 rev.B • 10/15
Page 9
8
Attach Pivot Covers
2x
9
Attach Cable Management
a
c
b
d
For Warranty visit: www.ergotron.com/warranty For Service visit: www.ergotron.com For local customer care phone numbers visit: http://contact.ergotron.com