OWNER’S MANUAL

DIGITAL MULTIMETER

MRP #93-0187

SAFETY PRECAUTIONS/ WARNINGS

This Digital Multimeter is intended for INDOOR USE ONLY.

Pay close attention to WARNINGS stamped on the front and rear of the meter's case. These warnings, as well as all warnings and precautions used through out this manual, must be followed to avoid electric shock and/or personal injury.

The RESPONSIBLE PARTY shall be made aware that, if the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.

To prevent electrical shock and/or damage to the tester or the equipment under test, observe the following safety precautions:

DO NOT apply more than the rated voltage, as marked on the meter, between terminals or between any terminal and earth ground.

Use caution when working above 30V AC rms, 42 V peak, or 60 V DC. Such voltages pose a shock hazard.

To avoid false readings that could lead to possible electric shock or personal

injury, replace the batteries as soon as the low battery indicator displays.

Use ONLY those test leads or probes provided with the meter. DO NOT use thirdparty test leads or probes.

Always inspect the multimeter, test leads and any other accessories for damage prior to every use. If any damage is found, do not use tester until repairs are done.

Always consider electrical and electronic equipment to be ener-gized (live). Never assume any equipment is de-energized.

Never ground yourself when taking electrical measurements. Isolate yourself from ground by using dry rubber insulating mats to cover all exposed/grounded metal. Stand on rubber mats and wear dry clothing.

SPECIFICATIONS

GENERAL SPECIFICATIONS AND FEATURES

3-½ digit LCD display (maximum reading of 2000)

Manual range control

Automatic negative (-) polarity indication

Automatic zero adjustment

Over range indicator (except 10 A function). Displays "1" on LCD

• Low battery indicator. Displays battery symbol

 

on LCD

 

Safety standard: CE EMC/LVD. The meter is up to the standards of IEC1010 Pollution Degree 2, over voltage Category 2 (signifies protection against transient impulses at the local level mains electrical supply).

Equipment marked is protected throughout by Double or Reinforced Insulation.

Operating environment:

Temperature - 32° to 104° F. (0° C to 40° C)

Humidity - Less than 80% relative humidity (non-condensing) Altitude - up to 6562 ft (2000 meters)

Storage environment:

Temperature - 4° to 140° F (- 20° to 60° C)

Humidity - Less than 90% relative humidity (non-condensing)

Power Supply: One 9-volt (6F22) battery

Fuse: 315mA/250V 5X20 mm (Radio Shack, GMA/217 series; #270-1046) fuse

Dimensions:

Height - 5.50 in. (139 mm) Width - 3.50 in. (89 mm) Depth - 1.25 in. (32 mm)

Weight (including batteries): approximately 5.7 oz (170 g)

ELECTRICAL SPECIFICATIONS

Accuracy of specifications in the following tables are based on an operating temperature of 64°F to 82°F (18°C to 28°C) and a relative humidity of less than 75%.

Maximum voltage from V ma socket to COM socket is 500V AC/DC; from COM socket to ground is 300V AC/DC.

DC VOLTS

 

Range

Resolution

Accuracy

Overload

 

 

 

 

Protection

 

 

 

 

 

 

200mV

100μV

 

230 Vrms

 

2V

1mV

±(0.8% of reading

 

 

20V

10mV

+ 5 digits)

500V DC

 

200V

100mV

 

or AC

 

500V

1V

±(0.8% of reading

 

 

 

 

+ 5 digits

 

 

Input impedance: 10MΩ for all ranges.

 

 

 

 

 

 

RESISTANCE (OHMS)

 

 

 

Range

Resolution

Accuracy

Overload

 

 

 

 

Protection

 

 

 

 

 

 

200Ω

0.1Ω

±(1% of reading

 

 

2KΩ

1Ω

 

 

+ 5 digits)

250V DC/AC RMS

 

20KΩ

10Ω

 

 

 

 

 

 

200KΩ

100Ω

 

 

 

20M Ω

10K Ω

±(2% of reading

 

 

 

 

+ 5 digits)

 

 

Open Circuit Voltage: Approximately 3V

 

 

 

 

 

 

DIODE TEST

 

 

 

 

Function

Range

Resolution

Accuracy

Overload

 

 

 

 

 

Protection

 

 

 

 

 

 

 

Diode test

 

1mV

0.5 ~ 0.8V

250V

 

 

 

 

 

DC/AC

 

 

 

 

 

RMS

 

 

 

 

 

 

 

Open Circuit Voltage: Approximately 2.8V

 

 

Forward Voltage Drop: Approximately 1mA

 

 

 

 

 

 

 

DC AMPS

 

 

 

 

 

Range

 

Resolution

 

Accuracy

 

 

Overload

 

 

 

 

 

 

 

 

 

 

 

 

Protection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2000μA

 

1μA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20mA

 

10μA

±(1.5% of reading

0.315A/250V fuse

 

 

200mA

 

100μA

+ 5 digits)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10A

 

10mA

±(2% of reading

 

Non-Protected

 

 

 

 

 

 

+ 5 digits)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measuring time is equal to or less than 15 seconds and time

 

 

interval is equal to or over 15 minutes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BATTERY TEST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Range

 

Resolution

 

Overload Protection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.5V

 

 

10mV

 

0.315A/250V fuse

 

 

 

 

 

 

 

 

 

9V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC VOLTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Overload

 

 

Range

Resolution

 

Accuracy

 

Protection

 

 

 

 

 

 

 

 

 

 

200V

100mV

 

 

±(1.2% of reading

500V DC or AC

 

 

 

 

 

 

 

 

+ 10 digits)

 

 

 

 

500V

1V

 

 

 

 

 

 

 

 

 

 

 

 

Frequency: 40-400Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TESTING PROCEDURES

A. AC/DC VOLTAGE MEASUREMENT

WARNING

To avoid possible electric shock, instrument damage and/or equipment damage, DO NOT attempt to measure voltages ABOVE 500V AC/DC or take measurements if the voltage is unknown. 500V AC/DC between the COM and V jacks is the maximum voltage that this instrument is designed to measure. The "COM" terminal potential should not exceed 300V AC/DC measured to ground.

- 1 -

- 2 -