SERVICE
PRODUCT SUPPORT
BULLETIN
PSB
NO.:
P-0037
SUBJECT: CR-420 ANTI-STATIC
Reports from the field have suggested that some paper jams and circuit board damage is being caused by static build up, possibly due to incorrect installation or non-use of the paper rack.
In order to prevent static build up it is essential that certain parts of the printer are properly installed. Moreover, the A/C outlet must be the 3 prong type and grounded. The paper rack provides a discharge path for the static charge that accumulates on the paper. static build up could cause problems. need to be connected to have a complete ground path for static build up. Use the part numbers listed below if there is a need for replacement parts.
The "static ground brushes", which are not shown, are located on
Q;k!nner
through the "rack mounting units", on either side of the upper case. The "paper rack" is then grounded to the "lower case" through the "ground wire" at junction "A".
If the rack is not installed and grounded properly, the
side of the "printer cover". They connect to the "paper
DATE:12/19/88
PAPER SETUP
Page 2 shows the parts that
PARTS LIST DESCRIPTION PART NUMBER
------------------------------­Power Cord Set
Ground wire
Printer Cover Unit 84100-2002U2 Upper Case Unit Paper Rack Paper Roller Unit Lower Case Unit S-59 S-90
W-14
Paper Rack
Mounting Units
84101-5351U 84100-5170
84100-2001U1 84100-2070 84100-2078U 84101-2003U 84001-4028 84100-2127 84003-4003
N/A
EPSON AMERICA SERVICE, 23610 TEL0 AVENUE, TORRANCE, CALIF. 90505
NUMBER:
P-0037
PAGE:
Paper Rack
2 of 2
Wire
Paper grounding brushes are located on the inner side of the printer cover.
All the parts in this drawing are essential and must be engaged to ensure proper static discharge.