Enttec Hyperion 71025, Hyperion 71026, Hyperion 71027, Hyperion 71029, Hyperion 71028 User Manual

Hyperion User Manual
51164
For latest version visit:
www.enttec.com
January 19 ID: 3809208 1
Hyperion
INTELLIGENT GIGABIT SWITCH
Contents
Package Contents .................................................................... 2
Safety Information .................................................................. 2
Initial Setup ............................................................................... 2
Out of Box (Factory Settings) ............................................ 2
Finding IP Address Using NMU v1.9 ................................. 2
Default Login Details .......................................................... 3
Physical Dimensions ............................................................... 3
Specifications ........................................................................... 4
Hyperion Hardware Interface (Front) ................................. 5
LED Status .................................................................................. 5
Hyperion Hardware Interface (Rear) .................................. 5
Application Diagram ............................................................... 6
Ethernet Link Pin Out ............................................................. 6
Redundancy Link ..................................................................... 7
How to Access Web Interface?.............................................. 8
Hyperion Web Interface ......................................................... 9
Home Page ................................................................................ 9
Settings Page .......................................................................... 10
Change Password .............................................................. 10
Ports Page ................................................................................ 11
Link Aggregation .................................................................... 12
Administration ........................................................................ 13
Restore to factory defaults (web interface) ............... 13
Restore to factory defaults (reset button) .................. 14
Reboot .................................................................................. 14
Backup ..................................................................................14
Restore .................................................................................14
Firmware Update................................................................ 15
Tips and Tricks ........................................................................ 17
Hyperion not found by NMU ........................................... 17
Unsuccessful Firmware update, causes white page . 17
Settings do not Save ......................................................... 17
Redundancy Link Doesn’t work ...................................... 17
Connection Lost ................................................................ 18
Device connected to Hyperion, not found ................. 18
Device not discovered on reconnection ..................... 18
Settings for your Computer .............................................19
Steps for Windows 7 ......................................................19
Steps for MacOS ............................................................ 20
Available Models .................................................................... 21
Ordering Information ............................................................ 21
Accessories and Recommended Products....................... 21
Hyperion User Manual
51164
For latest version visit:
www.enttec.com
January 19 ID: 3809208 2
Package Contents
Hyperion (71025, 71026, 71027, 71028 or 71029)
2m cat5 cable (79102)
Safety Information
This unit is intended for indoor use only
Do not expose this device to rain or
moisture, doing this will void the warranty
Make all the connections before you plug in
the mains power
Do not remove the cover, there are no user
serviceable components inside
Never plug this unit into a dimmer pack
Ensure proper earth connections
Always be sure to mount this unit in an area
that will allow proper ventilation. Allow about 6” (20 cm) between this device and a wall
Power-supply cords should be routed so
that they are not likely to be walked on or pinched
Initial Setup
Out of Box (Factory Settings)
All Hyperion devices come with the following default settings:
IP: 192.168.0.10
Subnet Mask: 255.255.255.0
Gateway: 0.0.0.0
If multiple Hyperion units are connected to the same network, manually change the IP address to
avoid any conflicts.
Finding IP Address Using NMU v1.9
Connect Hyperion directly to a computer
using a cat5 cable
NOTE
The computer should have the following network adapter settings:
o Static IP: 192.168.0.1 o Subnet Mask: 255.0.0.0 o Gateway: 0.0.0.0
Open ENTTEC NMU. If prompted with
multiple networks, select the correct one (identified by the IP address of your computer)
Press Discovery button and wait until NMU
finds all supported ENTTEC devices
Once found, select Hyperion and use the IP
address listed to access the web-interface via your web browser
Hyperion User Manual
51164
For latest version visit:
www.enttec.com
January 19 ID: 3809208 3
Type in the default IP shown on NMU into
any browser
Log into the device as shown in window
below:
Default Login Details
The log in details for the device are as follows:
Username: admin
No password (leave empty)
Once logged in, set the device with the appropriate network configurations
.
Physical Dimensions
Hyperion User Manual
51164
For latest version visit:
www.enttec.com
January 19 ID: 3809208 4
Specifications
Item
Model SKU
71025
71026
71027
71028
71029
Input Voltage
90-264 V AC
Input Frequency
47-63 Hz
Temp.
Storage
-20°C to 70 °C
Working
0°C to 40 °C
Humidity
Storage
5% to 90% non-condensing
Working
10% to 90% non-condensing
Connectors
1X powerCON IN
6X Front etherCON connectors
2X Rear etherCON connectors
1X 1000M SFP port
1X
OpticalCON
Duo (Front)
N/A
1X
OpticalCON
Duo (Rear)
1X LC Duplex
connector
(Front)
1X LC Duplex
connector
(Rear)
IP Rating
IP20
Cooling Method
Fan (always on)
Maximum Power
60 W
Power Supply Protection
Over-current
Auto recovery
Over-temperature
Latch
Short
Auto recovery
Over-voltage
Auto recovery
MAC Address table limit
8192
Maximum frame length
9216 B
Cache
32 Mb
Switching Capacity
52 Gbps
IGMP support
Yes (V1/V2)
IGMP snooping (multicast)
Yes, enabled by default
Net Weight
2.5 kg / 5.52 lb
Gross Weight
2.8 kg / 6.18 lb
Dimensions (without ears) L x W x H
445.82 mm x 180.29 mm x 43.20 mm
17.55 in x 7.10 in x 1.70 in
Dimensions (with ears) L x W x H
483 mm x 180.29 mm x 43.20 mm
19.02 in x 7.10 in x 1.70 in
Packaging Dimensions
533 mm x 247 mm x 111 mm
21.78 in x 9.72 in x 4.37 in
Ethernet Compliance
IEEE 802.3, IEEE 802.3u, IEEE 802.3x Flow Control, IEEE 802.3ab Gigabit Ethernet
Due to continuous improvements and innovations of all ENTTEC products, specifications and features are subject to change without notice.
Hyperion User Manual
51164
For latest version visit:
www.enttec.com
January 19 ID: 3809208 5
Hyperion Hardware Interface (Front)
LED Status
Power LED
Status LED
Operation
Green (static)
Amber
Device loading firmware
Green (Static)
Green (Blinking)
Normal operation
Green (Static)
No lit
Rebooting
Hyperion Hardware Interface (Rear)
Hyperion User Manual
51164
For latest version visit:
www.enttec.com
January 19 ID: 3809208 6
Application Diagram
Ethernet Link Pin Out
Pin
Colour
1
White/Orange
2
Orange
3
White/Green
4
Blue
5
White/Blue
6
Green
7
White/Brown
8
Brown
Hyperion User Manual
51164
For latest version visit:
www.enttec.com
January 19 ID: 3809208 7
Redundancy Link
Redundancy link is the ability of two ports of Hyperion to be connected to the same networking device. Redundancy link will automatically take over the signal within milliseconds, once link failure is detected.
Notes:
Redundancy link must be enabled (check from Home page for Ports 7 and 8)
If Hyperion is restored to factory defaults, redundancy link will be disabled for all ports
To enable redundancy link for Ports 7 and 8, simply load the Home page once
To enable redundancy link for other Ports, use Ports page
Can only be enabled/disabled when Port is not in use (not connected)
Link Aggregation takes priority over Redundancy (Ports 1 to 6 only)
Loading...