Enttec DMX ETHERGATE MK3 Quick Start Manual

Page 1
Quick Start Manual
50687 (NC)
for more information visit:
www.enttec.com/e3
DMX ETHERGATE MK3
( P N 7 0 0 7 0 )
DMX Ethergate Mk3 (pn: 70070)
Straight connect Ethernet lead (pn: 79102)
IEC power cord (country dependent plug)
This user manual
1RU Mount Bracket Kit (pn: 79105)
Features
2 fully independent bi-directional DMX ports (5 pin Female XLR connectors).
2 Universe Ethernet to DMX node (Output mode)
2 Universe DMX to Ethernet (Input mode)
Can be used as either 2 input, 2 output or 1 in 1
out ports.
Easy to setup & update through any web browser
Supports following DMX over Ethernet protocols:
Art-Net
Streaming ACN (sACN)
ESP
Supports RDM over Art-Net
RGB LED shows current system status
HTP Merging support : up-to 2 DMX sources can
be merged (if enabled).
1 RJ45 Ethercon connector (10/100)
Static or Dynamic (DHCP) IP configuration (DHCP by
default)
Easy firmware upgrades via any web browser
Reset button to perform factory restore
Inbuilt Auto ranging (90-260V) Mains power supply
Safety
Do not expose the Ethergate Mk3 to rain or moisture, doing this will void the warranty
Do not remove the cover, live voltage inside
This unit is intended for indoor use only
Basic Setup
Right out of the box, the Ethergate Mk3 is factory configured to be a DMX OUTPUT device, listening to the first two Art­Net Universes (starting from 0x00). It is also set as a DHCP node, so you can plug it into your existing router, and it's good to go.
To make any changes to the configuration, you will need the IP address of Ethergate. ENTTEC provides a free App (available for Windows and Mac) called NMU, which will find the Ethergate on your network and display its IP address.
Using the IP address one can access the built-in web­interface inside the Ethergate Mk3 via any modern web­browser. The web-interface allows the settings of the unit to be changed.
1
Page 2
Quick Start Manual
50687 (NC)
for more information visit:
www.enttec.com/e3
Once setup, any Art-Net/sACN/ESP enabled software/app or a lighting control/desk can be used to send DMX out of the Ethergate Mk3. For a list of recommended apps, please check the website www.enttec.com/e3
Status LEDs
The Ethergate Mk3 comes with one RGB status LED and two green network LED indicators located on the right side of the front panel
RGB Status LED:
WHITE: idle, signifies that Ethergate is operating
normally.
GREEN: DMX Output or Input on Port1. The led
will fade from white to green. Please disable the Port1 if you don't want it to function. Flashing Green indicates RDM.
YELLOW: DMX Output or Input on Port2. The led
will fade from white to yellow. Please disable the Port2 if you don't want it to function. Flashing Yellow indicates RDM.
RED: (Blinking)Error State. No DMX will be input
or output in this state. Requires a firmware update or needs to be rebooted. A reset might be required, if it stays in error-mode on reboot.
PURPLE: (Blinking) IP Address Conflict. Please
change the IP address manually or enable DHCP.
CYAN: (Blinking) Merging conflict. Multiple DMX
Sources detected, either Merging is disabled or number of sources exceed 2 (for the same universe). User action is required to allow proper DMX output.
Ethernet Link Speed: is ON when there is an active
Ethernet Link @ 100 mbps. It will stay OFF @ 10 mbps.
Ethernet Activity: This LED blinks when there is activity
on the Ethernet network.
NMU
NMU (Node Management Utility) is a free Windows and Mac application that is used to manage compatible ENTTEC DMX over Ethernet nodes.
NMU will help you find your unit's IP address and then open a browser window to access the web-interface.
Please Follow these steps:
1. Download NMU from www.enttec.com/nmu
2. Ensure that your Ethergate Mk3 is hooked up physically by Ethernet cable.
3. And connected to the same physical network (or router) as the computer on which you will run NMU.
4. Open NMU. If prompted with multiple networks, select the correct network. (identified by the IP address of your computer on that network)
5. Press the Discovery button, and wait till NMU finds all supported ENTTEC devices on your network.
6. Once found, select Ethergate Mk3 and use the IP address to access the web-interface via your web browser.
Web Configuration
The Ethergate Mk3 is configured and controlled through a web browser running on a computer system located on the same Local Area Network. Any modern web browser, such as Chrome, Firefox, Internet Explorer, Safari or Opera, running under any operating system, including Windows 7/8, Mac OS X or Linux can be used.
2
Page 3
Quick Start Manual
50687 (NC)
for more information visit:
www.enttec.com/e3
Either click on the underlined url displayed, or type the IP address (as detected by NMU) into your web browser to access the Ethergate Web Interface. The left side menu allows all the Ethergate web pages to be accessed.
System Information: Name, Firmware Version
and Serial No. of the unit. The Serial No. is unique to this unit and can be used to identify this unit.
Current Port Settings: Configured Port Type,
Protocol and Universe for each DMX Port. This serves as a quick place to check all the Port related settings.
Current Network Settings: Configured IP
address and Link speed for the unit.
Current DMX buffer: allows you to see the
current DMX values for each Port. The buffer is a snapshot only, but can be refreshed manually.
In the DMX Buffer table, you can hover the mouse over any value, and the channel number (1 to 512), for that value will be shown.
To change any of the settings, you must use the Settings page.
Network Settings
Node name is used to identify the Ethergate node on the network. Any meaningful name can be used.
DHCP is enabled by default. When enabled, the router on your network is expected to automatically provide the IP address to the Ethergate Mk3. If no DHCP router/server is present on the network, the manual IP address will be used.
If for some reason, your unit does not get an IP address via DHCP, please restart the Ethergate Mk3 with the ethernet cable connected. It will listen for DHCP on startup and wait for a few seconds, before giving up.
IP Address and Netmask are only used if DHCP is disabled or is unavailable on your network. Ethergate Mk3 will warn you, if non-standard IP address or netmask is used.
If ever you manage to use an IP Address that can't be connected to later, please perform the reset procedure (as described later). The reset will re-enable DHCP on the Ethergate Mk3.
Input Send Mode : allows you to pick either broadcasting or a specified unicast IP address (per port). Broadcast address is based on the subnet mask shown.
Both ports share the broadcast options selected here, but the unicast address can be specified as needed for each port separately.
Art-Net Address: Net and Subnet can be selected here, and comply to Art-Net 3 protocol. These address are applicable to both ports, whereas the universe can be selected for each port separately.
sACN CID: The current CID for Ethergate Mk3 is displayed here, and will be use in all sACN communication.
3
Page 4
Quick Start Manual
50687 (NC)
for more information visit:
www.enttec.com/e3
Port Settings
Port Types:
Output: Ethernet to DMX Output, based on the
selected protocol.
Input: DMX Input to Ethernet, sends the
selected protocol on the network.
Disabled: Does not process any DMX (input or
output).
RDM Enabled: Enables RDM over Art-Net
support on the port. Only available when Art­Net is selected and Port Type is output.
Protocol and Universe must be selected to match the settings of the remote sender or receiver connected to the LAN.
Refresh Rate
The rate at which Ethergate Mk3 will output the Data from DMX port (40 Frames per second is default). It will repeat the last received LAN frame to comply with DMX standard. However, if you do not want to repeat the last frame use 0 as the refresh rate, at 0 – it will match the rate at which the source sends at.
Merging Support
Merging option is only available when port is set to Output. Any incoming DMX on the same universe, but from different IP addresses is treated as a separate DMX source. Available Merging options :
disabled: (by default) only one source should be sending to the DMX output. Using multiple sources will cause a conflict and the output might have unexpected data.
HTP Merge: Highest Takes Precedence. Channels are compared one to one and the highest value is
set on the output. Merging is limited to two sources, any additional sources will be ignored by Ethergate Mk3. If either one of the 2 sources of DMX stop, the failed source is held in the merge buffer for 4 seconds. If, during the 4 second timeout, the failed source returns, Merging continues.
Merging conflict: A warning will be displayed on the home-page, if more than two sources are sending data to Ethergate Mk3 on the same universe. Status LED will blink CYAN to indicate merging conflict.
Unicast option
Send DMX to a single IP address rather than broadcast. Unicast is only available when port is set to Input. Any valid IP address can be used to Unicast DMX. You must select Unicast under Network Settings to use Unicast per port.
Save or Reset
To save all the changes made, please click on Save Settings and wait for Ethergate to confirm (takes up-to 5 seconds). Once confirmed you will be taken to the home-page.
Reset to defaults, will put all the settings back to their default values (network & port settings). Ethergate Mk3 will be reset to Factory condition.
Reboot – will restart the Ethergate.
Update Firmware
From this page you can update the latest firmware of the Ethergate Mk3 (firmware file is available at
www.enttec.com/e3).
4
Page 5
Quick Start Manual
50687 (NC)
for more information visit:
www.enttec.com/e3
Choose or browse the firmware file (as per your browser) and click on Update firmware to start the process.
The Status led will blink red during firmware mode.
The update progress is shown in real-time, and will take a few seconds for the update to complete
When the update is complete, the page will refresh and you will be taken to the home page – where you can verify the firmware version. If the update fails for any reason, please try the same process again.
Since, Ethergate Mk3 will reboot after a firmware update, please allow a few seconds for it to be refreshed in the browser. Please wait until the update process is complete.
Reset button
The reset button restores the network configuration of the Ethergate Mk3 to factory defaults:
DHCP is set to enabled
Static IP address is mapped to the Serial number
of the unit (used if DHCP is unavailable).
For example, a Serial No. of 2176541 will have a default Static IP address at 10.17.65.41
Netmask is set to 255.0.0.0
To successfully reset to factory defaults the Ethergate Mk3, the following procedure must be performed:
Power off the unit
Press and hold the Reset button.
While holding the Reset button, power up the
unit, and keep holding the button for 3 seconds.
Release the Reset button once the status led starts blinking red.
Wait 3 seconds and cycle power
Art-Net Send Test
NMU can also be used to troubleshoot the DMX output on your Ethergate Mk3. Art-Net Test can be accessed from the top menu: Art-net Art-net Test
When first opened, the Art-Net is set to Disabled, please set it to Enabled, and then you can use either the DMX faders to test one or more DMX channels, or use the test-patterns from the options available. Please set the Ethergate Mk3 to be output and on the same universe as being used to send Art-Net from NMU.
DMX Connector pin out
5pin DMX OUT/ DMX IN:
Pin 1: Ground
Pin 2: Data -
Pin 3: Data +
Pin 4: NC
Pin 5: NC
Any suitable 3 to 5pin DMX adaptor can be used to connect to 3pin DMX cables or fixtures. Please note the pinout, before connecting to any non-standard DMX connector.
5
Page 6
Quick Start Manual
50687 (NC)
for more information visit:
www.enttec.com/e3
Specifications
Due to continuous improvements and innovations of all ENTTEC products, specifications and features are subject to change without notice.
Ordering Information
Ethergate Mk3 and related products can be ordered from our website or through your local ENTTEC dealer using the following part numbers.
ENTTEC PTY LTD ENTTEC AMERICAS 17/5 Samantha Court 604A Cornerstone Ct. Knoxfield Victoria 3180 Hillsborough NC 27278 Australia USA Tel: +61 3 9763 5755 Tel-Fax: (888) 454-5922 Fax: +61 3 9763 5688
email sales@enttec.com
www.enttec.com
6
Item Value
Input Voltage 90 – 260V AC
Input Frequency 50/60Hz
Weight 1.65 lbs / 0.75 kg
Shipped weight 3.19 lbs / 1.45 kg
Length 7.53” / 191mm
Width 4.14” / 105mm
Height 1.75” / 44.45mm
Op Environment 0°-50°C in non-condensing environment
Connectors
2x 5-Pin Female XLR (bi-directional DMX) 1x RJ45 Ethercon connector (10/100) 1x IEC power connector
Part Number Description
70070 DMX Ethergate Mk3
70023 5-pin Male to Male DMX Adapterr
70029 5-pin to 3-p in DMX Adapter
70006 2U 19 ” Rack Mount Kit
70035 1U 19 ” Rack Mount Kit
79122 5pin DMX Terminator
79134 5M 5-pin DMX Cable
Loading...