Enttec 8PL60-F-12 User Manual

8P (12 VOLT) PIXEL TAPE
INSTALLATION GUIDE ID: 3474813
FOLLOW THE INSTRUCTIONS BELOW OR
! !
MAXIMUM RUN LENGTH
COLOUR AND LUMEN OUTPUT WILL BE AFFECTED IF
CUTTING
ONLY CUT ALONG THE LINES MARKED ON THE TAPE MAXIMUM LENGTH IS EXCEEDED. TEST CONDUCTED AT MAXIMUM BRIGHTNESS USING 12 VOLT DRIVER.
MAXIMUM LENGTH
SINGLE POWER INJECTION
LEDS PER METRE WHITE
60
4.7m
RED,GREEN,BLUE
11.5m
GND
DI
12V
GND
GND
DO
DI
12V
12V
GND
GND
DO
DI
12V
12V
GND
GND
DO
DI
12V
12V
DUAL POWER
60
9.5m
11.5m
INJECTION
ADHESIVE APPLICATION
• THE TAPE WILL NOT ADHERE TO TEXTURED OR LOW SURFACE ENERGY MATERIALS
• THE BEST SURFACE FOR LONG LASTING ADHESION IS CLEAN RAW METAL
• CLEAN SUBSTRATE WITH ALCOHOL AND A CLEAN CLOTH
• PEEL OFF PROTECTIVE BACKING TO REVEAL ADHESIVE
• APPLY PRESSURE WHEN ADHESIVE FIXING TO SUBSTRATE
THERMAL MANAGEMENT
• THESE TAPES PRODUCE HEAT, THERMAL MANAGEMENT MUST BE CONSIDERED.
• THE MORE LEDS PER METRE THE MORE HEAT.
• ENTTEC RECOMMENDS USING AN ALUMINIUM PROFILE TO MANAGE HEAT.
• EACH APPLICATION IS DIFFERENT, ENTTEC RECOMMENDS TESTING A SECTION OF TAPE IN ITS FINISHED ENVIRONMENT TO ENSURE THE THERMAL MANAGEMENT IS SATISFACTORY.
WIRING SCHEMATIC
• SELECT THE MOST SUITABLE OPTION FROM BELOW. SOLDER OR CRIMP IS RECOMMENDED TO COMBINE MULTIPLE WIRES.
• IF WIRE COLOURS VARY AND YOU ARE UNSURE PLEASE CONTACT ENTTEC OR YOUR SUPPLIER FOR FURTHER ADVICE.
• THE MIDDLE WIRE WILL ALWAYS BE DATA.
GND
DO
12V
BLACK
GREEN
RED
GND
GND DI 12V
12V
GND
DO
12V
DATA JOIN
DO:
(DATA OUT)
DI:
(DATA IN)
GND DI 12V
GND
DO
12V
DUAL POWER INJECTION
GND
DATA
DATA JOIN WITH MULTIPLE SINGLE POWER INJECTIONS
VOLTAGE: 12
12V
WATTS: (STRIP LENGTH IN METRES) x (WATTS PER METRE)
12V (2)GND
SINGLE POWER INJECTION
GND
DATA
GND
PSU
DATA
12V (1)
DO NOT CONNECT 12V(1) TO 12V(2)
12V
VOLTAGE DROP TESTING
USE MULTIMETER TO TEST FOR VOLTAGE DROP TEST WHERE POWER IS INJECTED. IF PROBLEMS OCCUR ALSO METER THE END OF THE STRIP.
PUSH PROBES THROUGH
12
POWER INJECTION
11.7 - 12.2
12.311.6
SET LED COLOUR TO FULL WHITE END
PROTECTIVE SILICONE TO MAKE CONTACT
PAGE 1/1
ENTTEC RESERVES THE RIGHT TO MAKE CHANGES TO THIS PRODUCT AND RELATED DOCUMENTS AT ANY TIME WITHOUT NOTICE, THE MOST RECENT DOCUMENTATION IS AVAILABLE AT ENTTEC.COM
THIS DOCUMENT AND DESIGN IS PROPERTY OF ENTTEC. REPRODUCTION OR USE OF ANY MATERIAL CONTAINED WITHIN MUST BE APPROVED IN WRITING BY ENTTEC.
Loading...