www.energenics.com
1470 Don Street • Naples, Florida 34104 Telephone: (239) 643-1711
Fax: (239) 643-6081
Customer Service: (800) 944-1711
Installation & Operations Manual for Energenics Air Free Lint
Filters
Receiving and Installation Page 1
Receiving and Installation Page 2
Filter Dimensions Page 3
Maintenance Requirements Page 4
Parts List Page 5
1
Receiving and Installation
1. Inspect the filter inside and outside for damage.
2. Adjust the height and anchor the base plate to the floor.
3. Install the white mesh screen inside the filter housing.
4. Install the black vinyl lint bag to the bottom of the filter.
5. Duct individually from the dryers to the filter.
6. If the dryer ducts are too many or to large for the filter inlet have the
duct installer fabricate a short adapter inlet to match to the filter.
7. For Outside installations, specify the side discharge with rain hood
option from Energenics. Alternatively mount a “chinamans hat” on top
of the filter (18 inches open space from the filter to the “hat”) for
outside installation. Your local duct fabricator can fabricate the “hat”.
8. For low ceiling laundries us the Side Discharge O ption for horizontal
exhaust requirements.
9. The filter can be lowered to 16 inches from ground to filter bottom from
our recommended standard of 24 inches. The lint bag will simply be
harder to empty.
10. When ducting from the filter to the outside, direct the exhaust away
from sensitive air handling equipment, even minor lint by-pass clogs
compressors.
11. Duct runs longer than 50 feet to the filter are a problem, consult
Energenics for review.