Endress+Hauser t-switch Technical Information

t-switch
Technical Information TI014A/05/e/03.01
t-switch
Flow switch for liquid and gas
Product Structure ATT11-
Endress+Hauser Ltd. Floats Road Manchester M23 9NF United Kingdom Tel: 0161 286 5000 Fax: 0161 998 1841 www.uk.endress.com
Technical Information
TI014A/05/e/03.01
Approvals
A For use in non-hazardous areas B FM General Approval (pending) C CSA General Approval (pending) Y Special – please specify
Sensor Form 11 Flat face sensor 12 Flat face sensor, insertion 125mm 13 Flat face sensor, insertion 235mm 21 Probe sensor 22 Probe sensor, insertion 125mm 23 Probe sensor, insertion 235mm 99 Special – please specify
Process Connection
(Material 1.4435/316L unless stated) D1 G
3
/ 4
" BSP, (Boss Included)
D2 G
3
/ 4
" BSP, Brass (Boss Included) Brass compression fitting for insertion sensor only
F1 NPT
3
/ 4
" (Boss Included)
F2 NPT
3
/ 4
", Brass (Boss Included) Brass compression fitting for insertion sensor only
J1 DN40 Dairy coupling DIN 11851 K1 DN50 Dairy coupling DIN 11851 L1 Varivent >=DN50 M1 Tri Clamp 1
1
/ 2
" ISO2852
N1 Tri Clamp 2" ISO2852 P1 DN50 Aseptic coupling DIN 11864-1 Y9 Special – please specify
Surface Finish, Wetted Parts
1 Standard Metal Finish 2 Ra<1.5 µm/120 grit 3 Ra<0.8 µm/150 grit (3A/EHEDG) 5 Ra<1.5 µm/120 grit, O2duty 6 Ra<0.8 µm/150 grit, O2duty (3A/EHEDG) 7 Standard Metal Finish, O2duty 9 Special – please specify
Electronics & Outputs
A Relay Output, No Display, power supply –
18-30V DC/AC (50/60Hz)
B Relay Output, 4 digit LCD, power supply –
18-30V DC/AC (50/60Hz) St. St. Housing only
Y Special – please specify
Housing & Cable Entry 4D Polyester Housing IP66 M20 Gland 4H Polyester Housing NEMA4X NPT
1
/ 2
" entry
6D SS304 Housing IP66 M20 Gland 6H SS304 Housing NEMA4X NPT
1
/ 2
" entry
9Y Special – please specify
Documentation
1 Standard Documentation 2 EN10204-2.3 Pressure test
1.5 x pressure rating for 3 minutes
9 Special – please specify
ATT11- Order Code
United Kingdom All Other Countries
Performance and Selection
t-switch
Endress+Hauser 2
t-switch
Endress+Hauser1
Measuring Principle
Sensor Type
Liquid (flat face)
Figures referenced to water Ranged 0-1.5m/sec (provisional) Time Response: 5 sec rising
< 5 sec falling
(0-66% step change)
Gas (probe)
Figures referenced to Air Ranged 0-30m/sec (provisional) Time Response: 15 sec rising
10 sec falling
(0-66% step change)
Extended versions available with alternative process connections.
Thermal technology is a well established operating principle in the process industry used on a wide variety of applications. It operates by monitoring the cooling effect of a fluid stream as it passes over a heated transducer (RTD). The fluid flows over two RTD elements one of which senses the actual fluid temperature and provides a reference whilst the other is heated to ensure a constant differential temperature above the fluid temperature. The applied power needed to maintain this differential is proportional to the mass flow of the fluid.
Planning and Installation Guidelines
LIQUID
GAS
LIQUID
GAS
LIQUID (Partially Full)
LIQUID
GAS
LIQUID
GAS
LIQUID
GAS
LIQUID
GAS
LIQUID (Dirty)
52
29.5
Performance and Selection
Process Plant
Features and Benefits
Chemical Industry
Single device for liquids and gas
Wide dynamic rangeability
No moving parts reduced maintenance
Simple and reliable to install and programme
Wide selection of process connections
Incorporates fuzzy logic control algorithm allowing manual adjustment of meter sensitivity to suit
application requirements
Dry run protection for pumps
Control of cooling systems for pumps, turbines, compressors and heat exchangers
Water Treatment
Beverage Industry
Status indication of valves in water distribution systems
Chemical dosing
Air injection
Filter control
Monitoring cleaning processes
Dairy Industry
Cooling systems in refrigeration plants
Chemical dosing
Monitoring pump function
Applications
Mount upstream of control valves, hand or isolation valves
Ensure sensor is aligned with direction of flow (see manual)
For liquids ensure full pipes
Avoid areas of cavitation (liquids)
For gases avoid areas where condensate collects
Avoid applications with large process temperature changes
Avoid mounting device where exposure to extreme ambient temperature changes occurs e.g.
direct sunlight