Endress+Hauser t-switch Technical Information

Page 1
t-switch
Technical Information TI014A/05/e/03.01
t-switch
Flow switch for liquid and gas
Product Structure ATT11-
Endress+Hauser Ltd. Floats Road Manchester M23 9NF United Kingdom Tel: 0161 286 5000 Fax: 0161 998 1841 www.uk.endress.com
Technical Information
TI014A/05/e/03.01
Approvals
A For use in non-hazardous areas B FM General Approval (pending) C CSA General Approval (pending) Y Special – please specify
Sensor Form 11 Flat face sensor 12 Flat face sensor, insertion 125mm 13 Flat face sensor, insertion 235mm 21 Probe sensor 22 Probe sensor, insertion 125mm 23 Probe sensor, insertion 235mm 99 Special – please specify
Process Connection
(Material 1.4435/316L unless stated) D1 G
3
/ 4
" BSP, (Boss Included)
D2 G
3
/ 4
" BSP, Brass (Boss Included) Brass compression fitting for insertion sensor only
F1 NPT
3
/ 4
" (Boss Included)
F2 NPT
3
/ 4
", Brass (Boss Included) Brass compression fitting for insertion sensor only
J1 DN40 Dairy coupling DIN 11851 K1 DN50 Dairy coupling DIN 11851 L1 Varivent >=DN50 M1 Tri Clamp 1
1
/ 2
" ISO2852
N1 Tri Clamp 2" ISO2852 P1 DN50 Aseptic coupling DIN 11864-1 Y9 Special – please specify
Surface Finish, Wetted Parts
1 Standard Metal Finish 2 Ra<1.5 µm/120 grit 3 Ra<0.8 µm/150 grit (3A/EHEDG) 5 Ra<1.5 µm/120 grit, O2duty 6 Ra<0.8 µm/150 grit, O2duty (3A/EHEDG) 7 Standard Metal Finish, O2duty 9 Special – please specify
Electronics & Outputs
A Relay Output, No Display, power supply –
18-30V DC/AC (50/60Hz)
B Relay Output, 4 digit LCD, power supply –
18-30V DC/AC (50/60Hz) St. St. Housing only
Y Special – please specify
Housing & Cable Entry 4D Polyester Housing IP66 M20 Gland 4H Polyester Housing NEMA4X NPT
1
/ 2
" entry
6D SS304 Housing IP66 M20 Gland 6H SS304 Housing NEMA4X NPT
1
/ 2
" entry
9Y Special – please specify
Documentation
1 Standard Documentation 2 EN10204-2.3 Pressure test
1.5 x pressure rating for 3 minutes
9 Special – please specify
ATT11- Order Code
United Kingdom All Other Countries
Performance and Selection
Page 2
t-switch
Endress+Hauser 2
t-switch
Endress+Hauser1
Measuring Principle
Sensor Type
Liquid (flat face)
Figures referenced to water Ranged 0-1.5m/sec (provisional) Time Response: 5 sec rising
< 5 sec falling
(0-66% step change)
Gas (probe)
Figures referenced to Air Ranged 0-30m/sec (provisional) Time Response: 15 sec rising
10 sec falling
(0-66% step change)
Extended versions available with alternative process connections.
Thermal technology is a well established operating principle in the process industry used on a wide variety of applications. It operates by monitoring the cooling effect of a fluid stream as it passes over a heated transducer (RTD). The fluid flows over two RTD elements one of which senses the actual fluid temperature and provides a reference whilst the other is heated to ensure a constant differential temperature above the fluid temperature. The applied power needed to maintain this differential is proportional to the mass flow of the fluid.
Planning and Installation Guidelines
LIQUID
GAS
LIQUID
GAS
LIQUID (Partially Full)
LIQUID
GAS
LIQUID
GAS
LIQUID
GAS
LIQUID
GAS
LIQUID (Dirty)
52
29.5
Performance and Selection
Process Plant
Features and Benefits
Chemical Industry
Single device for liquids and gas
Wide dynamic rangeability
No moving parts reduced maintenance
Simple and reliable to install and programme
Wide selection of process connections
Incorporates fuzzy logic control algorithm allowing manual adjustment of meter sensitivity to suit
application requirements
Dry run protection for pumps
Control of cooling systems for pumps, turbines, compressors and heat exchangers
Water Treatment
Beverage Industry
Status indication of valves in water distribution systems
Chemical dosing
Air injection
Filter control
Monitoring cleaning processes
Dairy Industry
Cooling systems in refrigeration plants
Chemical dosing
Monitoring pump function
Applications
Mount upstream of control valves, hand or isolation valves
Ensure sensor is aligned with direction of flow (see manual)
For liquids ensure full pipes
Avoid areas of cavitation (liquids)
For gases avoid areas where condensate collects
Avoid applications with large process temperature changes
Avoid mounting device where exposure to extreme ambient temperature changes occurs e.g.
direct sunlight
Page 3
t-switch
Endress+Hauser 4
t-switch
Endress+Hauser3
18-30V AC/DC (50/60Hz)
24V DC @ 0.5 A 120V AC @ 0.5
A
Power
1
+
2
-
3
4
For BSP and NPT threads
"L"
Process Connection Extended Sensor
Planning and Installation Guidelines
Sensor Orientation
Each process connection has an orientation mark, this should be positioned in line facing the oncoming flow.
Sensor should be installed such that the sensing surface is in contact with the flowing medium at all times.
There is an allowed orientation tolerance of +/- 5° from centre.
Sanitary Sensor
It is the responsibility of the user to ensure that the volume enclosed by the mounting boss has sufficient dimensions to ensure adequate cleaning takes place.
Mounting and Installation
Note:
5º 5º
Flow Direction
Electrical Connection
Operation
Insertion Sensor
Mounting Boss
Accessories
Display socket
LED for Switchpoint/Error Indication
Note: In order to meeet EMC requirements, screened or shielded cable is recommended.
8 DIL Programming Switches
LED (Light Emitting Diode)
Illuminates when measured flow above switchpoint.
Off when measured flow below switchpoint.
Flashes to indicate an error.
LCD (Liquid Crystal Display)
Optional display used to indicate flow as a percentage of maximum. Also displays programming information and error codes (not essential for programming).
Threaded Flanges
with G
3
/
4
BSP or
3
/
4
NPT thread for mounting a t-switch. Available sizes: DN25 PN25
ANSI 1" 150lbs DN40 PN25 ANSI 1
1
/
2
" 150lbs DN50 PN25 ANSI 2" 150lbs
Avoid installing in areas of extreme flow turbulence. For example:
Directly after bends or expansions/reductions.
All downstream dimensions provided only as a guideline and wherever possible greater dimensions should be considered.
Directly after pumps, fans and compressors.
>10 dia
Directly downstream of isolation and
control valves.
>50 dia
>25 dia
H =
1
/
3
D
Dimensions of extended versions (L in mm)
Sensor Option
Flat-Face
Probe
Insertion 125mm
125 125
Insertion 235mm
235 235
Side view End view
Page 4
t-switch
Endress+Hauser 6
t-switch
Endress+Hauser5
All dimensions in mm
Polyester Housing
No display
Steel Housing
No display
Steel Housing with
Extended Lid
With display
Housing and Sensor
Process
Connection
Dimensions with Flat-Face Sensor
Dimensions with
Probe Sensor
Process Limits
Process Connection
Process Conditions
Materials
Process Connections
Performance Limits
Human interface
Electrical
BSP
3
/
4
" (G)
max 25 bar A
max 80°C
52
29.5
3
/
4
" NPT
max 25 bar A
max 80°C
29.5
12.8
Sanitary coupling
DN40 DN50
to DIN 11851
max 25 bar A
max 80°C
29.5
Varivent
DN50
max 10 bar A
max 80°C
29.5
68
Triclamp
1
1
/
2
"
2"
ISO 2852
max 16 bar A
max 80°C
29.5
Aseptic coupling
DN50
to DIN 11864
max 25 bar A
max 80°C
29.5
52
36
52
52
52
52
85
max 76
max 130
76
max 64
max 125
76
max 64
max 145
Technical Data
Nominal Process Diameters: DN25-1000
Process Pressure Range: 25 Bar g (Process fitting dependent)
Process Temperature Range: -10 to +80°C
Meter Body: 1.4404/1.4435/316L
Transducers: 1.4404/1.4435/316L
Polyester Housing: PBT-FR (polyester) with cover in PBT-FR or with transparent cover in PA 12,
Seal of cover; EPDM
Steel Housing: 1.4301 (AISI 304), seal of cover silicone
Cable Gland: Polyamide
Parallel thread BSP
3
/
4
" (includes brass
3
/
4
" compression fitting for insertion sensors only)
Tapered thread
3
/
4
" NPT (includes brass
3
/ 4
" compression fitting for insertion sensors only)
Sanitary coupling DN40, 50 to DIN 11851
Varivent DN50 to factory standard Tuchenhagen
Triclamp 1
1
/
2
", 2" to ISO 2852
Aseptic coupling DN50 to DIN 11864
Accuracy: ± 5% of full scale
Repeatability: ± 1% of full scale
Time Response Flat Face: 5 sec rising, < 5 sec falling
Time Response Probe: 15 sec rising, 10 sec falling
Flow Ranges Liquid: 0-1.5m/sec ref. to water (provisional)
Flow Ranges Gas: 0-30m/sec ref. to air (provisional)
Electronic Insert: 8 DIL switches for commissioning
Red LED to indicate switching status, flashes under fault condition
Optional Display: 4 numeric characters with bar graph
Power Supply: 18-30V DC /AC (50/60 Hz)
Power Consumption: <3W
Relay Output: Selectable Normally Closed (NC) or Normally Open (NO) (NO as factory default)
Environment
Storage Temperature Range: -20 to +80°C (without LCD)
Ambient Temperature Range: -10 to +65°C (without LCD)
Degree of Protection: Polyester and steel housings: IP66 to EN 60529
Vibration Resistance: Up to 1g, 10....150Hz to IEC 60068-2-6
Shock Resistance: to IEC 60068-2-31
Electromagnetic Compatibility (EMC): IEC 801 part3: E = 10V/m (30MHz...1GHz)
Approvals
Approvals Pending
EHEDG, all wetted materials FDA listed. Meets the requirements of 3A.
CSA General Approval, FM General Approval.
Loading...