ENDA ET1412 User Manual

Page 1
Technical Specifications
Thank you for choosing ENDA ET1412 temperature controller.
Please read this document carefully before using this product. The guarantee will be invalidated if the device is damaged by not following instructions detailed in the manual. The company shall not be responsible for any damage or losses however caused, which may be experienced as a result of the installation or use of this product.
Connection Diagram
ENDA ET1412 is intended for installation in control panels. Make sure that the device is used only for intended purpose. The electrical connections must be carried out by a qualified staff and must be according to the relevant locally applicable regulations. During an installation, all of the cables that are connected to the device must be free of electrical power. The device must be protected against inadmissible humidity, vibrations, severe soiling and make sure that the operation temperature is not exceeded. The cables should not be close to the power cables or components.
1/2
SÝSEL MÜHENDÝSLÝK ELEKTRONÝK SAN. VE TÝC. A.Þ. Yukarý Dudullu Barbaros Cad. Kutup Sok. No:20 34775 - ÜMRANÝYE/ÝSTANBUL/TÜRKÝYE Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01 url : www.enda.com.tr
Panel cut-out
Dimensions
Note :
1) Panel thickness
should be maximum 7 mm.
2) If there is no 60mm
free space at the back side of the device, it
ET1412-E-07
71mm
29mm
Flush mounting
clamp
For removing mounting clamps:
Push the flush-mounting clamp in direction 1 as shown in the figure below. Then, pull out the clamp in direction 2.
1
ENDA ET1412 DIGITAL THERMOSTAT
* 35 x 77mm sized. * On-Off control. * Contact output for alarm. * Single contact output for selectable heating or cooling control. * Single NTC probe input.. * Offset value can be entered for NTC probe. * In the case of probe failure, output state can be selected on, off or periodical running. * Upper and lower limits of the set point can be adjusted. * Selectable independent, deviation or band alarm. * Temperature unit can be selected °C or °F. * CE marked according to European Norms.
Order Code     : ET1412-NTC- 
1
230VAC.......230V AC
24................24V AC/DC
12................12V AC/DC
Supply Voltage
OUTPUTS
Output
Alarm
Life expectancy for relay
Relay: 250V AC, 8A (for resistive load), NO+NC; 1/2 HP 240V AC CosF = 0.4 (for inductive load)
1/2 HP 240V AC CosF = 0.4 (for inductive load)
Relay: 250V AC, 8A (for resistive load), NO+NC;
Mechanical 30.000.000; Electrical 100.000 operation.
Holding screw
0.4-0.5Nm.
Equipment is protected throughout by DOUBLE INSULATION
7 8
SUPPLY:
NOTE:
184-253V AC 50/60Hz 3VA
Line
Neutral
230V AC Supply
Switch
Note:
Cable size: 1,5mm²
Fuse
F 100 mA
250V AC
Fuse should be connected
1) Mains supply cords shall meet the requirements of IEC 60227 or IEC 60245.
2) In accordance with the safety regulations, the power
supply switch shall bring the identification of the relevant instrument and it should be easily accessible by the operator.
ENVIRONMENTAL CONDITIONS
Height
Maximum 2000m
80%, up to 31°C decreasing linearly 50% at 40°C
Ambient/storage temperature Max. relative humidity
0 ... +50°C/-25 ... +70°C (with no icing)
Rated pollution degree
According to EN 60529 Front panel : Ip65
Rare panel : IP20
Do not use the device in locations subject to corrosive and flammable gasses.
Supply voltage
230V AC +10% -20%, 50/60Hz or 12/24V AC/DC ±10%, 50/60Hz.
Power consumption
Max. 3VA
2.5mm² screw-terminal connections.
(±1%-1sec) 4 digits, 12.5mm, 7 segment yellow LED
Wiring Scale Sensitivity/Accuracy
Time Accuracy Indicator EMC
Safety requirements
The device is designed to operate in controlled electromagnetic environment)
EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B is satisfied for EMC tests.
EN 61010-1: 2001 (Pollution degree 2, overvoltage category II)
ELECTRICAL CHARACTERISTICS
-60.0 ... +150.0°C (-76.0 ... +302.0°F)
0.1°C / ±1°C
CONTROL
Control type
Single-setpoint control On-Off control
Control algorithm Hysteresis
Adjustable between 0.1 ... 20.0°C.
HOUSING
Housing type
Suitable for flush-panel mounting.
Dimensions
W77xH35xD71mm
Weight
Approx. 215g (A ) fter packing
Enclosure material
Self extinguishing plastics
While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used.
Flush mounting
clamp
Depth
Panel
2
71mm
5mm
SET
SET
ENDA
OUT
°F
°C
ALR
ET1412
77mm
35mm
SET
SET
ENDA
OUT
°F
°C
ALR
ET1412
Rubber packing
SN: XXXXXXXXX
1 2 3 4 5 6
7 8 9
10
11 12
ET1412-NTC-230VAC
DIGITAL THERMOSTAT
ENDA INDUSTRIAL ELECTRONICS
230V AC +10% -20%
50/60Hz 3VA
OUTPUT
250V AC 8A
RESISTIVE LOAD
NTC
SENSOR
SN: XXXXXXXXX
1 2 3 4 5 6
7 8 9
10
11 12
ET1412-NTC-230VAC DIGITAL THERMOSTAT
ENDA INDUSTRIAL ELECTRONICS
230V AC +10% -20% 50/60Hz 3VA
OUTPUT
250V AC 8A
RESISTIVE LOAD
NTC SENSOR
ALARM
250V AC 8A
RESISTIVE LOAD
8 680 407 70552 8
Made in Turkey
SN: XXXXXXXXX
1 2 3 4 5 6
9
10
11 12
ET1412-NTC-12 DIGITAL THERMOSTAT
ENDA INDUSTRIAL ELECTRONICS
OUTPUT
250V AC 8A
RESISTIVE LOAD
NTC SENSOR
ALARM
250V AC 8A
RESISTIVE LOAD
12V AC/DC 10% 50/60Hz 3VA
±
7 8
8 680 407 70555 9
Made in Turkey
24V AC/DC 10% 50/60Hz 3VA
±
SN: XXXXXXXXX
1 2 3 4 5 6
7 8 9
10
11 12
ET1412-NTC-24 DIGITAL THERMOSTAT
ENDA INDUSTRIAL ELECTRONICS
OUTPUT
250V AC 8A
RESISTIVE LOAD
NTC SENSOR
ALARM
250V AC 8A
RESISTIVE LOAD
8 680 407 70554 2
Made in Turkey
Page 2
SET
SET
ENDA
OUT
°F
°C
ALR
ET1412
A.Lol
min = 0,1°C,
max = 60°C
A.uPL
A.Lol
min = -60°C,
max = 60°C
A.uPL
A.Lol
min = -60°C,
max = 150°C
A.uPL
o.HYS
Output hysteresis
o.PPn
On time for the output in the case of probe failure.
o.PPF
Off time for the output in the case of probe failure.
Unit dres
Temperature unit.
C.tyP
Control mode (Heat = Heating control , Cool
=Cooling control.)
1.0
°C °F °C
°C
2
20.0
0
255
Min.
0
0
255
Min.
1
Heat Cool
Heat
no
yes
no
Menu of Congiguration
Cn
PARAMETER TABLE
-60.0
-20.0
o.LoL 150.0
MIN
UNIT
MAX
DEFAULT SET
o.uPL
-60
°C °C
150
°C
020.0
Menu of Output control parameters
o.LoL o.uPL o.oFF
The lower limit of the setpoint The upper limit of the setpoint
The offset value for the output
ouou
Çýkýþ kontrol parametreleri menüsü
ou
Menu of Alarm control parameters
AL
A. ou-
A.ou.S.
Security parameter for menu of output control
= Menu is invisible.
NonE P.yes P.no
= Parameters of menu are changeable.
= Parameters of menu are only visible.
= Setpoint value is changeable.
= Setpoint value is only visible.
P.yes P.no
Security parameter for output setpoint value
Menu of Parameter security
SE
A. Cn-
Security parameter for menu of configuration
Security parameter for menu of alarm
A. AL-
in.AL
20.0
°C
2
in.AL
bo.AL
A.HYs A.typ
Alarm hysteresis value.(*)
Alarm type.
0.1
(*) alarm set value.
If one of the band alarm types are selected, alarm hysteresis value should not be greater than
(No = no decimal point. 22
Decimal place yes = with decimal point. 22.3 °C )
°C°C
A.LoL A.uPl
The lower limit of Alarm sepoint.
The upper limit of Alarm sepoint.
A.uPL
A.lol
(**)
(**)
°C
°C
-60
150
(**) Min. value of parameter and max. value of A.uPL parameter are at the alarm types diagram.A.LoL
Alarm type
A.upL
Alarm hysteresis value.
A.Lol
A.typ
A.Hys
The upper limit of Alarm setpoint.
The lower limit of Alarm setpoint.
ET1412-E-07
2/2
Used for selecting menu and increasing setpoint value of the parameters in the programming mode and for increasing the setpoint value in the run mode. When held down for a few seconds, the change rate accelerates.
Used for selecting parameters and decreasing the setpoint value in the programming mode and for decreasing the setpoint value in the run mode. When held down for a few seconds, the change rate accelerates.
OUT LED
FAHRENHEIT LED
Displayed process value in the run mode, parameter name or value in programming mode.
Used for adjusting the value of the setpoint in the run mode and for adjusting the selected parameter in the programming mode. While holding key, setpoint value of the selected parameter appears and by using and keys the value can be adjusted.
The lower limit of the setpoint.
Programming Mode
Run Mode
o.lol
The offset value for the output
o.off
Output hysteresis
o.Hys
The upper limit of the setpoint.
o.uPl
If both keys are pressed, run mode is entered.
ou
o.PPF
o.PPn
On time for the output in the case of probe failure.
Off time for the output in the case of probe failure.
Security parameter for configuration menu
A.-Cn
Security parameter for alarm menu
A.-AL
A.-ou
Security parameter for output menu
S.Cod
Access code for security menu. This parameter should be
321 .
Se
AL
Control mode
C.typ
Decimal place
Unit
Cn
Temperature unit
dres
Security parameter for output setpoint value
A.ou.S.
Pfa
Means, thermostat probe is short circuit.
Psc
Means, thermostat probe is broken.
Error Messages
Pfa
PsC
Temperature value is higher than the scale.
Temperature value is lower than the scale.
ALARM LED
A.Set
A.Set
A.Hys
A.Hys
Alarm on
Alarm off
Alarm on
Alarm off
Alarm on
Alarm Output Types
- °C
- °C
- °C
+ °C
+ °C
+ °C
-60
Alarm off
Alarm on
Alarm off
- °C
+ °C
-60
+60
+60
ATyP In.AL
=
(Independent alarm is actived below the setpoint)
Alarm off
- °C
+ °C
-60
+60
ATyP de.AL
=
(Deviation alarm is actived below the setpoint)
ATyP In.AH
=
(Independent alarm is actived above the setpoint)
A.Hys
ATP DAH
=
Alarm on
- °C
+ °C
-60
+60
(Sapma alarmý, set deðerinin üstünde aktif)
ATyP de.AH
=
(Deviation alarm is actived above the setpoint)
A.Hys
(Alarm is actived inside the band)
ATyP bi.AL
=
A.Hys
A.Hys
( outside the band)
Alarm is actived
ATyP bo.AL
=
A.Hys
A.Hys
o.Set
+
A.Set
o.Set
o.Set
+
A.Set
o.Set
-
A.Set
o.Set
o.Set
+
A.Set
o.Set
o.Set
+
A.Set
o.Set
-
A.Set
o.Set
Process Value
30.0
o.Set
A.Set
30.0
25.0
If key is pressed, o.SEt (Output setpoint value) and A.set (Alarm setpoint value) parameters appear.
While holding key o.set value appears and by using and keys the value can be adjusted between
o.lol and o.upl values.
While holding key A.set value appears and by using and keys the value can be adjusted according to
A.typ parameter which is specified table of alarm output types.
If both keys are pressed and held for 3 seconds, programming mode is entered.
A.Lol
min = 0,1°C,
max = 60°C
A.uPL
A.Lol
min = -60°C,
max = 60°C
A.uPL
A.Lol
min = -60°C,
max = 150°C
A.uPL
SET
SET
SET
SET
SET