Enda EPV242-R-230VAC-RS, EPV242-230VAC-RS, EPV242-R-110VAC-RS, EPV242-110VAC-RS, EPV242-R-24VAC-RS User manual

...
english
Read this document carefully before using this device. The guarantee will be expired by damaging of the device if you don't attend to the directions in the user manual. Also we don't accept any compensations for personal injury, material damage or capital disadvantages.
ENDA EPV242 PROGRAMMABLE AC/DC VOLTMETER
Thank you for choosing AC/DC voltmeter.ENDA EPV 42 2 Programmable
77 x 35 mm sized 4 digits display Selectable number of decimal point Indicates between -999V and +9999V by using voltage transformer Easy to use front panel keypad Multi-function alarm output for lower and upper limits (NO + NC) Multi-function alarm setpoints with alarm output (NO) Communication feature over isolated RS485, using ModBus RTU protocol (Optional) Measuring type can be selected as AC, DC or true RMS CE Marked according to Europan Norms.
Order Code : EPV242 - - -
1 32
1 - Output
R..........Relay
Blank....N/A
2 - Supply Voltage
230VAC...230V AC 110VAC...110V AC
24VAC.....24V AC
SM...........9-30V DC / 7-24V AC
3 Isolated ModBus -
RS ...... ModBus
I Isolated
Specify at order
( )
Technical Specifications
ENVIRONMENTAL CONDITIONS
Ambient / torage emperature S T Max. elative umidityR H Rated ollution egreeP D Height
Do not use the device in locations subject to corrosive and flammable gases.
0 ... +50°C/-25 ... +70°C (with no icing) 80% Relative humidity for temperatures up to 31°C, decreasing linearly to 50% at 40°C. According to EN 60529 5, ; Front Panel : IP6 Rear Panel : IP20
Max. 2000m
OUT AC DC ACDC
0.000
ENDA
V
SET
EPV242
ELECTRICAL CHARACTERISTICS
Supply Voltage Power onsumptionC Wiring
Scale
Sensitivity
Accuracy
Input Range
Input Impedance Frequency Range
EMC Safety equirementsR
OUTPUTS Alarm Output
Life Expectancy for Relay
HOUSING
Housing ypeT Dimensions Weight
Enclosure aterialM
230V AC +10 -20 or 24V AC %10, 50/60Hz or 9-30V DC / 7-24V AC 10% % % (Optional)± ±
Max. 5VA
2.5mm² screw-terminal connections
AC and RMS DC
0,01V ( If, or is selected )u100 utrr
0,1V ( higher than ) If, is selected and -100V, lower from 100V for input valuesu500
1V ( lower than -100V 100V ) If is selected and , higher from for input valuesu500
AC DC RMS
and
9
and
10
and
9
and
10
DC , 10Hz - 200Hz (For square wave form 10Hz-70Hz) EN 61326-1: 2013 EN 61010-1: 2010 (Pollution degree 2, overvoltage category II)
Relay: 250V AC, 8A (for resistive load), NO+NC Mechanical 30.000.000 operation; 100.000 operation at 250V AC, 2A resistive load.
Suitable for flush-panel mounting. (According to DIN 43 700) W77xH35xD 1mm6 Approx. 50g (after packing)2
Self extinguishing plastics.
For 0...9999V, for 0........100V, for 0...500Vutrr u100 u500
For -999...9999V DC, for -100...100V DC, for -500...+500V DCutrr u100 u500
±
( Full scale ) ( For square wave form 2% )±
%1
±
( )Full scale
%1
( Full scale ) ( For square wave form 2% )±
±
12 11 12 11
%1
-500V...500V at ). 10 10 or
- 0V... 0V at
870kΩ
u500
(Dielectric strength up to 1250 Vdc, above that the device will be damaged
utrr u100
±
±(Dielectric strength up to 250 Vdc, above that the device will be damaged).
While cleaning the device, solvents (thinner, gasoline, acid etc.) or must not be used.corrosive materials
SURAN Industrieelektronik
Dettinger Str. 9 / D-72160 Horb a.N
Tel.: +49 (0)7451 / 625 617 Fax: +49 (0)7451 / 625 0650
E-mail : info@suran-elektronik.de Internet : www.suran-elektronik.de
EPV242-E-150419
1. / 4
8680407704910
DIMENSIONS
8 68 0 407 704934
8 68 0 407 704903
8 68 0 407 704910
8 68 0 407 704927
77mm
OUT AC DC ACDC
0.000
ENDA
12
10
11
+
AC / DC Max.
100V
AC / DC
+
Max. 5
00V
SN: XXXXXXXXX
Depth
61mm
V
SETSET
EPV 242
Panel
Flush mounting
7 8 9
B
A
1 2 3 4 5 6
COM.
50/60Hz 5VA 230V AC +10% -20%
CAT II
Made in Turkey
AC/DC VOLTMETER PROGRAMMABLE
EPV242-230VAC-RSI
ENDAINDUSTRIAL ELECTRONICS
clamp
2
Panel cut-out
71 mm,5
5mm
Rubber packing
For removing mounting clamps :
- 1
Push the flush-mounting clamp in direction as
shown in the figure left.
- 2
Then, pull out the clamp in direction .
Note :
1)2) Panel thickness should be maximum 6 mm.
There must be at least 60mm free space behind the device, otherwise it would be difficult to remove it from the panel.
Holding screw
0.4-0.5Nm.
1
Equipment is protected throughout by
DOUBLE INSULATION
Connection Diagram
ENDA EPV242 is intended for installation in control panels. Make sure that the device is used
only for intended purpose. The electrical connections must be carried out by a qualified staff and must be according to the relevant locally applicable regulations. During an installation, all of the cables that are connected to the device must be free of electrical power. The device must be protected against inadmissible humidity, vibrations, severe soiling. Make sure that the operation temperature is not exceeded. The cables should not be close to the power cables or components.
.If input type is selected, the measurement terminals 9 and 12 of the terminals must be connected Otherwise, measurement will be incorrect.1tYp u500
If input type “ ” or is selected, the measurement terminals 10 and 11 of the terminals must be connected. Otherwise, measurement will be
1tYP u100 utrr
incorrect.
ENDAINDUSTRIAL ELECTRONICS
EPV242-230VAC-RSI
PROGRAMMABLE AC/DC VOLTMETER
Made in Turkey
CAT II
230V AC +10% -20% 50/60Hz 5VA
1 2 3 4 5 6
ENDAINDUSTRIAL ELECTRONICS
EPV242-R-230VAC-RSI
PROGRAMMABLE AC/DC VOLTMETER
Made in Turkey
CAT II
OUTPUT 250V AC 8A RESISTIVE LOAD
230V AC +10% -20% 50/60Hz 5VA
1 2 3 4 5 6
A
0
-A
A
0
A
0
A
0
-A
A
0
A
d
0
A
0
-A
T
T/2
T
3T/2
T/2
T/2
T/2
T/2
3T/2
T
T
T/2
3T/2
T
d
T
T
3T/2
COM.
B
B
COM.
3T/2
2T
3T/2
2T
2T
A
7 8 9
A
7 8 9
2T
2T
A
2T
Max. 5
+
AC / DC
+
Max. 5
+
AC / DC Max.
AC / DC
+
ac
1
A
2
0.308 A
0.386 A
A
1
A
2
d T
1
A
3
SN: XXXXXXXXX
00V
Max.
100V
AC / DC
11
10
SN: XXXXXXXXX
00V
100V
11
10
2
d
2
T
ENDAINDUSTRIAL ELECTRONICS
EPV242-230VAC
PROGRAMMABLE AC/DC VOLTMETER
Made in Turkey
CAT II
230V AC +10% -20% 50/60Hz 5VA
12
12
0.000
A
0.000
A
0.000
1 2 3 4 5 6
ENDAINDUSTRIAL ELECTRONICS
EPV242-R-230VAC
PROGRAMMABLE AC/DC VOLTMETER
Made in Turkey
CAT II
OUTPUT 250V AC 8A RESISTIVE LOAD
230V AC +10% -20% 50/60Hz 5VA
1 2 3 4 5 6
(rms)
dc
A
Ac.dc
1
A
2
2
π
1
π
1
A
2
1
A
2
A
1
A
2
d T
1
A
2
d
A
T
1
A
3
7 8 9
7 8 9
UP.l1 HYS.U +
LO.l1 HYS.L +
A.out n.o. =
A.out n.c. =
Input
UP.l1
LO.l1
OUT1
OUT1
SN: XXXXXXXXX
Max. 5
+
AC / DC Max.
AC / DC
+
10
SN: XXXXXXXXX
Max. 5
+
AC / DC Max.
AC / DC
+
10
00V
100V
11
00V
100V
11
12
dly.U
Supply:
184-253V AC 50/60Hz 5VA
4
Phase Neutral
5
Fuse F 100mA 250V AC
Switch
12
OUTPUT CHART
dly.U
dly.ldly.l
t
t
t
SURAN Industrieelektronik
Dettinger Str. 9 / D-72160 Horb a.N
Tel.: +49 (0)7451 / 625 617 Fax: +49 (0)7451 / 625 0650
E-mail : info@suran-elektronik.de Internet : www.suran-elektronik.de
EPV242-E-150419
2. / 4