Emerson Electric AMS Trex User Manual

Reliability Solutions
AMS Trex™ Device Communicator
Commission and validate devices faster
Automatically synchronize eld changes
Quickly x issues in the eld with advanced
device diagnostics
Congure and test valves inline
Improve efciency with a modern,
intuitive user interface
Intrinsically safe; usable anywhere you need to go
With the Trex communicator, you can do more in the eld than ever before.
Product Data Sheet
June 2020

Introduction

The AMS Trex Device Communicator expands the long line of Emerson handheld devices while adding new capabilities that adapt it to consumer expectations
for mobile device functionality.
Technicians armed with a Trex communicator won’t waste time bringing devices back to the shop for analysis or reconguration. AMS Trex is delivered with a complete, pre-installed DD library for over 2,000 HART and Foundation Fieldbus devices so users can easily diagnose device problems in the eld. Simple issues can be addressed on the spot, avoiding unnecessary, and potentially destructive, invasive physical investigation of the problem.
Technicians need powerful and portable diagnostic tools so
they can identify and troubleshoot device issues to minimize
process upsets. With a Trex communicator in hand, you can properly diagnose device issues in the eld. With the right handheld, maintenance teams will experience signicant savings in work hours and peace of mind knowing that problems will be xed quickly and properly the rst time.
Once changes are made in the eld, AMS Trex will automatically synchronize the information with the AMS Device Manager
database via Wi-Fi or USB connection.

Rugged and Reliable

For a communicator to be useful in the eld, it must be built to last and ready for anything. The Trex communicator is designed to withstand the harsh conditions in and around manufacturing facilities. The rugged device is easy to hold, yet designed to take
the bumps and drops that come from normal use in the plant.
In addition, the Trex communicator is protected against moisture and extreme temperatures, allowing you to work regardless of environmental conditions. The sturdy exterior is designed in accordance with Intrinsic Safety standards to limit the buildup of static electrical energy. Unlike consumer-grade mobile devices, the Trex communicator will withstand the abuse of a harsh eld environment.
Designed based on user feedback and with eld use in mind, the carrying case features an access window that allows you to use the communicator and contains pockets large enough to carry the charger, extra lead sets, or other tools you may need in the eld.
AMS Trex Device Communicator
The rugged form factor is built for an industrial environment.

Adjustable Display

The Trex communicator features a 5.7” resistive touchscreen display for easy use with bulky work gloves. The adjustable backlit screen can be easily changed to save power or adapt to dark environments or bright sunlight, ensuring a crisp display that can always be read - no matter the external conditions.

An App for That

June 2020
WirelessHART Provisioning – The WirelessHART Provisioning app allows you to provision wireless networks in less time,
with less chance of error and in a more secure fashion.
The app can congure hundreds of devices with a push of a button, improving accuracy and allowing you to provision an entire network up to 6x faster.
Radar Master – The Radar Master app enables you to ensure the measurement and conguration accuracy of your Rosemount radar level transmitters by bringing the power of Radar Master software to the eld. Use dynamic graphics to verify congurations while protecting the safety of your
personnel and assets.
ValveLink Mobile – With Valvelink Mobile, you can analyze
and review valve assembly condition and performance without
affecting the process. Conguration and troubleshooting of digital valve controllers has never been more efcient.
Calculator – The Calculator app for AMS Trex includes a simple calculator, conversion calculator for base conversions, loop convertor/Ohm’s law calculator, and unit converter for engineering units.
Trex Help – The Trex Help app offers a searchable help guide, putting key information on operation and troubleshooting at your ngertips.
The Trex communicator includes Upgrade Studio, a PC application to help keep the Trex unit up-to-date with new
software and apps.
With Upgrade Studio, add critical diagnostic tools to your toolkit and push them out to any number of Trex
communicators. With multiple apps available and many
more in development, Upgrade Studio will make the Trex communicator your go-anywhere, do-anything device:
Field Communicator – The Field Communicator app delivers
a wide range of options for conguring and troubleshooting HART and Foundation Fieldbus devices.
Loop Diagnostics – With the Loop Diagnostic app, you can power the loop in the eld and also perform loop troubleshooting and checkouts. The app helps with loop
characteristic validation and lets you isolate and troubleshoot
wiring issues.
Fieldbus Diagnostics – The Fieldbus Diagnostics app gives you the necessary toolset for troubleshooting and validating
Foundation Fieldbus segments.
PDF Viewer – Transfer PDF les to AMS Trex to easily access manuals, work processes, notes, and any other PDFs in the eld.

Designed for Use

Designed for comfortable, one-handed, all-day operation in the eld, the Trex communicator is packaged in an evenly­balanced form factor with a rugged hand strap so you can easily hold it, even when working in tight spaces. It comes standard with 32 GB of application memory, providing plenty of space
to customize it with the apps of your choice. With built-in
USB and Wi-Fi connectivity, you can move data to and from the communicator using the connectivity option that is most convenient. With numerous communication options,
your communicator has never been more connected.
The communicator’s robust lithium-ion power module will keep it running for hours, well over a full shift, even when it is being used to power other devices in the eld.
www.emerson.com/trex 2
AMS Trex Device Communicator
June 2020

Intrinsically Safe

The Trex communicator is built to go wherever you may need to be. Unlike consumer mobile devices that cannot be taken
into hazardous areas without shutting down the process or pulling a hot work permit, the Trex unit meets global Intrinsic Safety requirements:
 ATE X
 CSA (US/Canada)
IECEx
 FISCO
Gain freedom and exibility with a communicator that can go anywhere you need to, when you need to, without worrying if
the device will put you at risk.
Powering devices from the communicator allows you to isolate the device from the rest of the system, helping you identify installation problems like power supply, wiring, I/O card, and conguration issues.

Auto Sync

The Auto Sync technology in AMS Trex helps maintain data integrity in your AMS Device Manager database without any technician intervention. Every change made in the eld is
automatically recorded and time-stamped.
Changes are updated in real-time if Wi-Fi connection is enabled and a technician is in a hot spot. Or changes are cached on the Trex communicator and applied to the database when the communicator detects a Wi-Fi signal or USB cable connection.
The Trex communicator logs and timestamps changes as they occur, delivering an accurate audit trail of device changes to the AMS Device Manager database.

Powerful Diagnostics

Identify Valve Problems
Manage loop health easily with the Trex communicator.

Power the Loop

The Trex communicator includes built-in functionality to power
a device. Simply connect the communicator to an instrument
to power it. Technicians no longer waste time rounding up a power supply or conrming adequate loop resistance before testing, speeding conguration on the bench.
Power the loop functionality allows device conguration in the eld on new projects—even before power and I/O infrastructure are in place. Transmitter conguration no longer needs to be the last step of new projects. Congure transmitters before the host system, wiring, piping, and other project elements arrive, keeping transmitter conguration from being a critical path item, allowing more exibility in new project scheduling and leading to faster startups.
Valve problems are particularly costly to diagnose and repair. Field technicians are often required to pull a valve to investigate a problem, and removing valves for inspection usually means shutting down the process. Further complicating troubleshooting, technicians often need to disassemble
the valve to determine the root cause of the problem.
This frequently leads to further damage to the valve, ending in a more time consuming and expensive repair.
Using the ValveLink Mobile app on the Trex unit, you can perform valve diagnostics in the eld, including valve signature, dynamic error band, PD one button sweep, and step response, without having to pull the valve or perform invasive troubleshooting steps. ValveLink Mobile works with HART and Foundatio n Fieldbus Fisher® FIELDVUE™ digital valve controllers and provides an intuitive user interface that is easy to understand and use. With the AMS Trex Device Communicator Plus communication module, you can even power the digital valve controller directly from ValveLink Mobile. The large touchscreen on the Trex communicator makes it easier than ever to see all valve diagnostic details.
www.emerson.com/trex 3
Loading...