Emerson STC 642, STC CCTV, STC DRS, STC TEL RJ, STF Active Tracking Filters Brochure

...
surge protective Devices (spD) anD filtering
“enDuring protection”
INTRODUCTION
SolaHD understands that your operations depend on clean, continuous power. That’s why, since 1915, SolaHD has focused exclusively on being the premier brand for industrial power quality by eliminating the power interruptions, transients and noise that can stop production and corrupt data. Our full breadth of products convert, clean and maintain electric current from the factory entrance to equipment throughout your facility. Combined with service and support, our total power quality offering can save you time, money and space to ensure optimal production efciencies.
INTRODUCTION 2
PRODUCT OVERVIEW 4
SURGE PROTECTIVE DEVICE/FILTER - APPLICATION SELECTION TABLE 5
UL 1449 AND IEEE 6
SURGE PROTECTION
STV 200/400K Series 7
STV 100K Series 10
STV 25K DIN Rail Mount Series 12
ACTIVE TRACKING® FILTERING WITH SURGE PROTECTION
STF Series Active Tracking® Filters 14
STFV Plus Series Active Tracking Filters with Surge Protection (Chassis Mount) 17
STFE Elite Series Active Tracking Filters with Surge Protection (DIN Mount) 20
DATA/SIGNAL LINE SURGE PROTECTION
STC Series of Data/Signal Line Surge Protection 22
2
HOW DO YOU PROTECT YOUR POWER?
Employing an entire facility protection strategy will safeguard the electrical system against most transients. Multi-stage protection involves clamping the initial high energy surge, ltering any remaining noise or transients to the protected sensitive equipment and nally, protecting the data/signal lines entering or leaving the control panel or the factory oor. This coordination of devices provides the lowest possible let through voltage to the equipment.
B
STV 100K Surge Suppressor Device (SPD)
Surge Suppressor STV100k Series
1
LINE
SERVICE
Distribution
Transformer
STV 200/400K Service Entrance Surge Protective Device
Surge Protective Device STV200/400K Series
FULL
MODULE
PROTECTION
MODULE
DISABLED
TEST
LINE
REDUCED PROTECTION
1 2
ALARM
2
Surge Suppressor
2
LINE
STV100k Series
1
LINE SERVICE
STV 100K Surge Protective Device (SPD)
Surge Suppressor
2
LINE
STV100k Series
1
LINE
SERVICE
C
A
STC-PoE
Ethernet Surge Protective Device
(located behind server)
S5K Modular UPS
K-Factor Harmonic Transformer
LVGP Transformer
SDU Off-Line UPS
Solatron Plus Three Phase Power Conditioner
MCR Series
Constant Voltage
Power Conditioner
STC-DRS DIN mounted Surge Protective Device For Data
D
Signals
4
5
6
LINE
LINE
STS-DRS-060
SHIELD
1
2
3
OK
Active Tracking Filter STF Elite Series
STF Elite Active Tracking Filter With Surge Protection
E
STC-CCTV Surge Protective Device For Coaxial
C A B L E
STC-CCTV-751
E Q U I P
F
4 5 6
LINE LINE SHIELD
STS-DRS-060
1 2 3
OK
Active Tracking Filter STF Elite Series
G
L L1
N
LOAD
L2
G G
Status OK
Active Tracking Filter
STFV Plus Series
STFV Plus Series
Surge Protection and Active Tracking Filter
LINE L L1
N L2
G G
A STV 200/400K: Surge protective devices capable of handling
the high-impulse, potentially damaging transients commonly found at the service entrance, distribution panels, and placement in the most severe exposure locations.
B STV 100K: Surge protective devices designed to protect
sensitive equipment and microprocessor-based systems from transients on distribution and sub-distribution panels, or any medium exposure locations.
C STC-POE: Surge protective devices designed to work on
Power-over-Ethernet Category 5 PoE transmission lines as well as Category 6 applications.
D STC-DRS: DIN Rail mountable, single pair, low voltage data,
surge protective devices. e hybrid design of these data/ signal line protective devices allows them to respond quickly.
E STFE: DIN Rail mountable high-frequency noise lter/surge
protection that oers the original Active Tracking Filter technology with UL approved transient protection to guard against commonly occurring, but very damaging transients, plus provides excellent noise reduction.
F STC-CCTV: Surge protective devices tailored to protect CCTV,
data, audio and cable applications.
G STFV: High-frequency noise lter/surge protection that
oers the original Active Tracking technology with transient protection to guard against commonly high voltage transients, plus provides excellent noise reduction.
3
SURGE PROTECTION, FILTERING, DATA/SIGNAL LINE PROTECTION
SURGE PROTECTION • First Line of Defense in Limiting High-Impulse Transients
High-energy transients either externally or internally generated pose an immediate threat to the reliability and performance of your sensitive electronic equipment. SolaHD recommends placing high­energy Surge Protective Devices (SPDs) on key panels throughout your facility. Within your facility, motors, inductive loads and various equipment load switching can cause damage or costly downtime.
Our surge protective devices focus on limiting high-voltage spikes to a level that is acceptable to most electronic equipment. Plus, they’re a great rst line of defense, using components that are placed in parallel with the line and serve as clamping mechanisms for high­energy impulses. Protection at this level is referred to in the industry as Sine Wave Tracking or electronic grade. Surge Protective Devices are typically installed at service entrances and on larger distribution panels.
ACTIVE TRACKING FILTERING WITH SURGE PROTECTION • Provides Clean AC Power by Eliminating Low-Voltage Noise
Service Entrance/ Sub Panels
STV 200/400K
• Typical applications of 800 amperes and above
• Surge current
capacity – 200,000 to 400,000 Amps per phase
Low-energy transients and high-frequency noise are the primary causes for system disruption and long-term degradation of microprocessor­based equipment within your facility. For more than 30 years, our Active Tracking Filters have proven to be the most eective solution in critical equipment protection within harsh industrial environments. Active Tracking Filters are built upon a unique multi-stage hybrid design. is design creates a foundation for a family of products that attenuate impulses that would normally go untouched by standard, parallel clamping devices.
Changing technology and dependence on total automation processes within modern facilities create a critical need for clean AC power at the equipment level. Active Tracking Filters are a perfect solution for your microprocessor-based products, including industrial PLCs, OEM applications and motion control systems.
STFE Elite Series
• DIN mount
• Critical loads up to 20
amperes of continuous current
Branch Distribution
STV 100K
• Typical applications
up to 1,200 amperes
• Surge current
capacity – 100,000 Amps per phase
STF & STFV Series
• Hard-wired connection
• Critical loads up to 30
amperes of continuous current
Point of Use Locations
STV 25K
• Typical applications
of 20 amperes and below
• Surge current
capacity – 25,000 Amps per phase
DATA/SIGNAL LINE SURGE PROTECTION • Designed to Protect Sensitive Instrumentation
e rapid development of automated controls, telecommunications and re/alarm/security systems make it imperative to have properly coordinated low-voltage surge protection. Modern networked industrial facilities require error-free transmission of information for maximum productivity and integrity of data, but these areas are often overlooked when it comes to power protection.
e need to protect all susceptible low-voltage cable routes entering a facility and at key points within the building is as critical as protecting the equipment from high-energy impulses. e importance of protecting at this level grows as your facility’s reliance on sensitive instrumentation, networked automation, and uncorrupted data transmission increases. Our Data/Signal Line products utilize high-speed, high-energy components that come in a variety of voltage levels and unique packaging congurations.
4
POWER QUALITY SOLUTIONS
STC Series
• Three stage hybrid protection
• <1 nanosecond response times
• Variety of voltage and packaging congurations
SURGE PROTECTION
ACTIVE TRACKING FILTERING
WITH SURGE PROTECTION
DATA/SIGNAL
APPLICATIONS
STV 200/400K STV 100K STV25K STFE STFV STC
Facility Service
Entrance
Distribution Panels
Sub-Distribution
Panels
Branch Panelboards
(Commercial)
Branch Panelboards
(Residential)
Motor Control
Centers
Programmable
Logic Controllers
Control Panels
(AC Power)
Various OEM
Equipment
Transmitters
PoE
(Power-over-Ethernet)
Industrial
Communications
Programmable
Logic Controllers
(I/O Circuits)
Control Panels
(Low Voltage)
Water/Wastewater
Instrumentation
SURGE PROTECTIVE DEVICE/FILTER APPLICATION SELECTION TABLE
55
FOR ALL YOUR APPLICATION NEEDS
UL 1449 AND IEEE
Underwriters Laboratories (UL) Standard for Safety, Transient Voltage Surge Suppressors (UL 1449) has undergone a number of changes and will continue to drive application changes throughout the industry. is includes a change in nomenclature from transient voltage surge suppressors (TVSS) to surge protective devices (SPD) and recognition of the standard by the American National Standard Institute (ANSI). e adoption of the third edition of UL 1449 also aects performance testing methodologies, SPD ratings and the appropriate application of SPDs.
Prior versions of the standard did not take into account the performance of the protector. So many products have entered the market that essentially provided no benet, but were ‘safe for use’. To address this, UL under took these major changes and introduced a 2nd edition to the standard. Once the new standard was put into practice, it became clear there were still some more issues that needed to be addressed, therefore, UL decided to make further changes in the form of a 3rd edition to UL 1449.
ANSI/UL 1449 ird Edition Revisions Field Summary
SPD Locations by UL 1449 Types:
UL now categorizes surge protective devices (SPD) into categories based on its intended application.
• TYPE 1 - Connect anywhere in the customer’s facility – we strongly urge this to be specied for all critical installations.
• TYPE 2 - Connect downstream on load side of main breaker. Be aware that some competitors may have “conditions of acceptability” that can limit how the device is installed.
• TYPE 3 - Typically cord connected, plug in devices.
• TYPE 4 - Components
Nominal Discharge Current (I Nominal Rating):
is is the peak value of surge current which goes through the SPD (15 surges).
• TYPE 1 - UL tests to 10kA or 20kA. Not to be confused with maximum kA rating of the device. We recommend 20kA I Nominal rating be specied. While this is the highest UL rating, it is a low level surge which should be required by any device in even moderate exposure installations.
•TYPE 2 - UL tests to 3kA, 5kA, 10kA or 20kA I Nominal ratings. Again, 20kA is recommended for all specied SPD located at service entrances.
Voltage Protection Rating (VPR):
ese ratings replace the Suppressed Voltage Ratings (SVR) of the prior standard. UL uses a surge six times the current level of the SVR testing, so ALL measured VPR ratings are higher than the previous SVR rating.
All facilities that employ mission-critical electronic equipment should have a properly sized surge protective device (SPD) installed at the main electrical service entrance and throughout their facility at the distribution and branch levels. e surge protection connected to the incoming power line provides the rst line of defense against transient surges which are typically caused by nearby utility grid switching, lightning or other power disturbances. However, disturbances can be internally generated as well as externally generated so employing SPDs at key panels throughout your facility will also provide suitable downstream protection from external surges and local protection from internal high-energy transients caused by motors, inductive loads, and various equipment load switching that can also cause damage or costly downtime.
IEEE Standard 1100-2005, e Emerald Book: IEEE Recommended Practice for Powering and Grounding Electronic Equipment recommends a tiered SPD protection from your Service Entrance down to branch panel level.
7.2.4 Surge suppressors: “…Eective surge protection for an entire building power distribution system requires the coordinated use of large-capacity current-diverting devices at the service entrance followed by lower capacity voltage-clamping devices applied strategically throughout the power system.”
6
STV 200/400K SERIES
SolaHD STV 200/400K Series oers continuous protection from damaging voltage transients and electrical noise commonly found at the service entrance or distribution panel. e modular design of the STV 200/400K allows for installation exibility and the robust design allows for installation in the most severe exposure locations. ey are capable of handling the high-impulse, potentially damaging transients commonly found at the service entrance or distribution panels. e modular design of the STV 200/400K allows for installation exibility. e robust design allows for placement in the most severe exposure locations.
e STV 200/400K utilizes circuitry to monitor the status of all protection modes, including neutral to ground. Should protection be unavailable in any mode, the Green LED will be extinguished, and the Red LED will be illuminated. In addition, high isolation form C dry contacts provide remote monitoring of protection system failure, under voltage, phase and power loss. e STV 200/400K protection integrity monitoring indicates failure for both shorted or opened protection components.
ese devices are built to meet your unique requirements, and are available in hardwire, three phase conguration. ey are designed for years of trouble free operation and require little or no operator intervention after installation.
Applications
e STV 200/400K Series can be a facility-wide product family and may be installed from service entrances to distribution panels to branch panels.
Industrial Plants
Commercial Buildings
Institutional Facilities
Any facility that has an environment with electronics based
equipment
• Custom options (contact technical support)
- NEMA 12 enclosure, NEMA 3R, 4, and 4X
- Optional rotary disconnect, transient counter and remote monitor panel
Selection Table
CATALOG NUMBER
STV 400K-10Y
STV 200K-10Y
120/208 V ree-Phase Wye, 4-Wire + Ground
208 Y/120 V ree-Phase Wye, 4-Wire + Ground
INPUT
VOLTAGE
Features
• Modular design allows for exibility
• Surge current capacity of 200 to 400 kA per phase
• UL 1449 3rd Edition, Type 1, 20kA I-nominal approved
device
• Industry’s highest surge current repeatability
• All modes transient protection (L-N, L-G, and N-G)
• Form C dry contacts and audible alarm status indications
• Internal/external monitoring, including neutral to ground
• EMI/RFI Filtering
• Five year limited warranty
STV 400K-27Y
STV 200K-27Y
STV 400K-48D
STV 200K-48D
480 Y/277 V ree-Phase Wye, 4-Wire + Ground
480 Y/277 V ree-Phase Wye, 4-Wire + Ground
480 V ree-Phase ∆, 3-Wire + Ground
480 V ree-Phase ∆, 3-Wire + Ground
7
Surge protection
Specications
STV 200/400K SERIES
Parameters
STV200K-10Y STV200K-27Y STV200K-48D STV400K-10Y STV400K-27Y STV400K-48D
Catalog Number
208 Y/120 V 480 Y/277 V 480 V 208 Y/120 V 480 Y/277 V 480 V
Input Voltage
Maximum Continuous Operating Voltage (MCOV)
3Ph Wye,
4 W + G
3Ph Wye,
4 W + G
3Ph Delta,
3 W + G
3Ph Wye,
4 W + G
125% of the nominal level for 120 V; 115% for all other voltages
3Ph Wye,
4 W + G
3Ph Delta,
3 W + G
Line Frequency 47–63 Hz
Response Time < 0.5 ns
Enclosure Metal, UL Listed /NEMA type 12 (3R, 4, 4X also available)
Mounting Type Wall Mounted (mounting hardware ¼ in.)
Connection Internally connected
Status Indication Red and green LED status indicators, audible alarm, summary alarm contacts
Operating Temperature -40°C to +50°C
Operating Humidity 0% to 95% non-condensing
Noise Attenuation 50 dB maximum
Modes of Protection All Modes: L–N, L–L, L–G, N–G *
AIC Rating 200 kAIC
Nominal Discharge Current Rating (I
)
n
20 kA
Warranty 5 year limited warranty
rd
UL 1449, 3
Edition, Type 1 Voltage Protection Ratings (VPRs)
Line to Neutral 800 V 1200 V N/A 700 V 1200 V N/A
Line to Line 1200 V 2000 V 2000 V 1200 V 1800 V 2000 V
Line to Ground 900 V 1200 V 1800 V 800 V 1200 V 1800 V
Neutral to Ground 700 V 1000 V N/A 700 V 1000 V N/A
Peak Surge Current Capability
Per Phase 200 kA 200 kA 200 kA 400 kA 400 kA 400 kA
Line to Neutral 100 kA 100 kA N/A 200 kA 200 kA N/A
Line to Line 100 kA 100 kA 100 kA 200 kA 200 kA 200 kA
Line to Ground 100 kA 100 kA 100 kA 200 kA 200 kA 200 kA
Neutral to Ground 100 kA 100 kA N/A 200 kA 200 kA N/A
* Delta Model does not offer N–G mode of protection
8
Surge protection
STV 200/400K SERIES
8.25
(209.6)
1.30 max. (33.0)
12.00
(304.8)
14.25
(362.0)
16.25 (412.8)
16.75 (425.5)
0.31 (7.9)
Phase L1/A Phase L2/B Phase L3/C
Service Panel for
Loads to be Protected
Disconnect/Main
Neutral Bus
Ground Bus
Panel
Breaker for
Recommended Wire
Entrance
Dedicated
(Optional)
Disconnect
Summary Alarm Contacts (x2)
Pin 1 = Normally Open
Pin 2 = Common
Pin 3 = Normally Closed
TB1 TB2
1 2 3 1 2 3
Dimensional Drawings
Dimensional Specications
STV 200/400K SERIES
CATALOG NUMBER
STV200K
STV400K
CATALOG NUMBER
STV200K 38 (17.23) 8.25 x 14.25 x 16.25 40 A #8 15–175 A #14–2/0
STV400K 45 (20.41) 8.25 x 14.25 x 16.25 100 A #2 15–175 A #14–2/0
WEIGHT
LBS (KG)
35 (15.88) 8.25 x 14.25 x 16.25 40 A #8 15–100 A #14–2
42 (19.05) 8.25 x 14.25 x 16.25 100 A #2 15–100 A #14–2
WEIGHT
LBS (KG)
DIMENSIONS D x W x H (IN.)
Dimensions
D x W x H (IN.)
SUGGESTED
BREAKER SIZE
UNITS WITH ROTARY DISCONNECT
SUGGESTED
BREAKER SIZE
SUGGESTED WIRE
SIZE (AWG)
SUGGESTED WIRE
SIZE (AWG)
ALLOWABLE
BREAKER RANGE
ALLOWABLE
BREAKER RANGE
ALLOWABLE
WIRE
RANGE
ALLOWABLE
WIRE
RANGE
9
Surge protection
SolaHD’s STV 100K hardwired surge protective devices are designed for installation at the service entrance, branch panel or a dedicated sensitive electronic load. ese units feature all mode protection, LED and audible alarm status indication, sinewave tracking and form “C” dry contacts. e STV 100K series also contains the highest levels of safety built into the product including thermal fusing and a fault current fusing level of 65 kAIC.
Applications
• Distribution Panels (<1200 A)
• Branch, Lighting and Control Panels
• Factory Automation Installations
• Dedicated Industrial Equipment
Features
• 100,000 amp peak current rating provides all mode protection against severe transients
• UL 1449 3rd edition, Type 2, 3kA I-nominal approved device
• Low clamping levels for more eective protection
• 65 kAIC fault current fusing level provides safety
and NEC conformance
• LED status and audible alarms
• Compact, rugged metal
Selection Table
Dimensions
STV 100K SERIES
E324279
4.00
(101.6)
0.10 (2.5)
CATALOG NUMBER INPUT VOLTAGE
STV 100K-10S
STV 100K-10Y
STV 100K-10N
STV 100K-24L
STV 100K-23Y
STV 100K-27Y
STV 100K-24D
STV 100K-48D
STV 100K-10D4
STV 100K-24D4
10
120/240 V Single Phase, 3-Wire + Ground
208 Y/120 V ree Phase, Wye 4-Wire + Ground
120 V Single Phase, 2-Wire + Ground
240 V Single Phase, 2-Wire + Ground
230 Y/400 V ree Phase, Wye 4-Wire + Ground
480 Y/277 V ree Phase, Wye 4-Wire + Ground
240 V ree Phase, ∆ 3-Wire + Ground
480 V ree Phase, ∆ 3-Wire + Ground
240/120 CT ree Phase, ∆ 4-Wire + Ground
480/240 CT ree Phase, ∆ 4-Wire + Ground
Surge protection
6.00
(152.4)
Figure 1: Mechanical Dimensions Unit shown is a three-phase wye
6.75
(171.5)
0.38 (9.7)
0.50
(12.7)
2.00
(50.8)
3.20
(81.3)
STV 100K SERIES
Specications
DESCRIPTION
Nominal Input Vac 120/240 V 120 V 240 V 208 Y/120 V 400 Y/230 V 480 Y/277 V 240 V 480 V 240 D/120 V 480 D/240 V
System Conguration
Maximum Continuous Operating Voltage (MCOV)
Line Frequency 47-63 Hz
Response Time < 0.5 nsec
A/C Rating 65 kAIC
Fusing ermal and Fault Current
Nominal Discharge Current Rating
Modes of Protection
Operating Temperature
Operating Humidity 0% to 95% Non-condensing
Noise Attenuation 40 dB Max
Dimensions ­W x D x H - in. (mm)
Net Weight - lbs (kg) 8.0 lbs (3.63 kg) max.
Enclosure Metal, UL Listed/NEMA Type 12 Enclosure
Connection/ Mounting Type
STV 100K-10S STV 100K-10N STV 100K-24L STV 100K-10Y STV 100K-23Y STV 100K-27Y S TV 100K-24D ST V 100K-48D STV 100K-10D4 STV 100K-24D4
Single Phase
3 wire + Ground
Single Phase
2 wire + Ground
125% of the nominal level for 120 V; 115% for all other voltages
6.00 in. x 4.00 in. x 3.20 in. (152.4 mm x 101.6 mm x 81.3 mm)
CATALOG NUMBER
ree Phase Wye
4 wire + Ground
3 kA
All Mode: L- N, L - L, L - G, N - G
-40°C to +60°C
Parallel/Flange
ree Phase Delta
3 wire + Ground
ree Phase Delta High Leg
4 wire + Ground
Status Indication Red and green LED status indicators, audible alarm, Form C contacts
Warranty 10 year limited warranty
RD
UL 1449 3
Line to Neutral 600 V 600 V N/A 600 V 1200 V 1200 V N/A N/A 600 V 1200 V
Line to Line 1000 V N/A 1000 V 1000 V 2000 V 2000 V 2000 V 2000 V 1000 V 2000 V
Line to Ground 700 V 700 V 1200 V 700 V 1200 V 1200 V 1200 V 2000 V 700 V 1200 V
Neutral to Ground 700 V 700 V N/A 700 V 1200 V 1200 V N/A N/A 700 V 1200 V
High Leg to Neutral N/A N/A N/A N/A N/A N/A N/A N/A 1200 V 2000 V
High Leg to Line N/A N/A N/A N/A N/A N/A N/A N/A 1500 V 2500 V
High Leg to Ground N/A N/A N/A N/A N/A N/A N/A N/A 1200 V 2000 V
Per Phase 100 kA 100 kA 100 kA 100 kA 100 kA 100 kA 100 kA 100 kA 100 kA 100 kA
Line to Neutral 50 kA 50 kA N/A 50 kA 50 kA 50 kA N/A N/A 50 kA 50 kA
Line to Line 50 kA N/A 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA
Line to Ground 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA 50 kA
Neutral to Ground 50 kA 50 kA N/A 50 kA 50 kA 50 kA N/A N/A 50 kA 50 kA
EDITION, TYPE 2 VOLTAGE PROTECTION RATINGS (VPRS) VPEAK
PEAK SURGE CURRENT CAPABILITY
Surge protection
11
is series provides point-of-use protection, at the dedicated
2.56
(65.0)
4.87
(123.7)
4.75 (120.7)
equipment level, against damaging transients. Ideal for installation in electronic control cabinets found in harsh industrial environments such as the factory oor or at remote locations. ese devices provide 25,000 amps of surge protection per phase, sine wave tracking, LED status indication and form “C” dry contacts. is DIN Rail series also provides protection on all electrical paths and comes with a standard ten year product warranty. e STV 25K DIN Rail series surge protective devices are UL recognized to
rd
Standard 1449, 3
Edition.
Applications (20 Amp Max)
• Control Cabinets for Industrial Automation
• Point-of-Use Industrial/Service Equipment
• Remote Commercial or Industrial Equipment
• Instrumentation and Large Test Equipment
• Commercial and Building Automation Systems
STV 25K DIN RAIL SERIES
E335146
Features
• Compact and narrow design maximizes panel space.
• Low clamping levels for more eective protection.
• Easy access terminal screws for quick mounting and
installation.
• 25,000 amps of surge protection.
• Sine wave tracking and all-mode protection provide
consistent and reliable protection on all electrical paths.
• ermal fusing prevents MOV overheating caused by excessive current levels.
Selection Table
CATALOG NUMBER INPUT VOLTAGE
STV 25K-10S
STV 25K-24S
120 V Single Phase (L - N)
240 V Single Phase (L1 - L2)
Dimensions
12
Surge protection
STV 25K DIN RAIL SERIES
Specications
DESCRIPTION
Input Voltage 120 Vac, Single Phase 0-135 Vrms 240 Vac, Single Phase 0-260 Vrms
Maximum Continuous Operating Voltage (MCOV)
Line Frequency 47-63 Hz
Connection/Mounting Type
Input Current Rating 20 Amps
Phase Conguration 2 wire + GND
Weight - lbs (kg) 3.0 lbs (1.36 kg)
Dimensions H x W x D - in (mm)
Modes of Protection All Mode: L - N, L - L, L - G, N-G
Status Indication Green LED, Form C Contacts
Packaging Metal DIN Rail Mount Enclosure, IP20
Response Time < 0.5 nsec
Operating Temperature -40°C to +60°C
Operating Humidity 0% to 95% Non-condensing
Normal Mode Common Mode
L - N L - L L - G N - G
Line to Neutral 12.5 KA
Line to Ground 12.5 KA
Neutral to Ground 12.5 KA
Warranty 10 year limited warranty
STV 25K-10S STV 25K-24S
120 - 150 Vrms 240 - 275 Vrms
DIN Rail Mount (Chassis Mount Bracket Optional order
SDN-PMBRK2) with screw terminals for #12 AWG.
4.87 x 2.56 x 4.75 (123.7 x 65.0 x 120.7)
UL 1449, 3
RD
EDITION, TYPE 4 VOLTAGE PROTECTION RATINGS (VPR) VPEAK
500
— 500 500
PEAK SURGE CURRENT CAPABILITY (8 X 20 µS)
CATALOG NUMBER
includes mounting bracket
NOISE ATTENUATION
50 dB Min 40 dB Min
— 900 900
13
Surge protection
Low voltage/high frequency noise is caused by everyday events such as turning on machinery, motors, or equipment. Although noise is less dramatic than high voltage transients, the long term eects of these frequent disturbances can be as damaging. Filtering systems such as SolaHD Active Tracking® Filters provide clean AC power by eliminating lower voltage noise.
e SolaHD STF Series oers the original active tracking technology to guard against commonly occurring but very damaging, lower energy transients. Oering excellent noise reduction, the lter continuously tracks the input AC power line and responds instantly upon detecting extraneous high frequency noise.
e STF Series eliminates low voltage/high frequency noise via a low-pass or L-C lter. ese lters are used for low energy, high frequency noise reduction and consist of a series of inductors, capacitors and resistors. STFs are load dependent which means that the series inductors located on each phase and neutral conductors are sized to handle the maximum current draw on the line. ese inductors together with the capacitors and resistors form a circuit capable of absorbing a large bandwidth of noise.
ese devices are designed to meet UL 1283, and CSA C22.2 No. 8 for Electromagnetic Interference Filters. STFs attenuate or reduce the amplitude of noise to a minimum of 40dB that occurs in a frequency range of 50 KHz to 50 MHz. ey also provide the industry’s best IEEE Category “A” protection, typically reducing normal mode transients to +/- 5 volts.
Built to meet your unique requirements, these lters are available in a multitude of voltage congurations. ey are hardwired and designed for years of trouble free operation requiring little or no operator intervention after installation.
STF SERIES
E311348
Features
• Non degrading, series lter technology for total durability
• High frequency noise lter, RLC low-pass lter
• ree phase applications up to 200 Amp
• Attenuates noise to 40 dB in frequency range
of 50 kHz to 50 MHz
• Operating temperature from -40°C to +45°C.
• Hardwired connection
• MTBF greater than 100,000 hours, Mil Std. 217F
• Ten year limited warranty
Active Tracking® Filters are one part of a total power quality solution. ey can be used alone or in conjunction with other SolaHD products to solve more complex power quality problems.
Applications
• Branch and Control Panels
• Factory Automation Installations
• Point of Use Industrial Service Equipment
• Dedicated Industrial and Machine Tools Equipment
• Telecommunications Equipment
14
active tracking filtering with surge PrOtectiOn
STF SERIES
Selection Table
CATALOG NUMBER
STF0150-10Y
STF0300-10Y
STF0500-10Y
STF1000-10Y
STF2000-10Y
STF0150-24D
STF0300-24D
STF0500-24D
STF1000-24D
STF2000-24D
STF0150-27Y
STF0300-27Y
STF0500-27Y
STF1000-27Y
STF2000-27Y
STF0150-48D
STF0300-48D
STF0500-48D
STF1000-48D
STF2000-48D
AMPS
15.0 14 15A 18.75A
30.0 10 30A 37.5A
50.0 4 50A 62.5A
100.0 2 100A 125A
200.0 3/0 200A 250A
15.0 14 15A 18.75A
30.0 10 30A 37.5A
50.0 4 50A 62.5A
100.0 2 100A 125A
200.0 3/0 200A 250A
15.0 14 15A 18.75A
30.0 10 30A 37.5A
50.0 4 50A 62.5A
100.0 2 100A 125A
200.0 3/0 200A 250A
15.0 14 15A 18.75A
30.0 10 30A 37.5A
50.0 4 50A 62.5A
100.0 2 100A 125A
200.0 3/0 200A 250A
MIN. WIRE SIZE
(AWG SUGGESTED)
FUSE/CIRCUIT BREAKER AMPACITY
SUGGEST MAX
Three-Phase Models (120/208 Vac WYE) *
THREE-PHASE MODELS (240 V DELTA) *
THREE-PHASE MODELS (277/480 V WYE) *
THREE-PHASE MODELS (480 V DELTA) *
CASE DIM.
IN (MM) - A X B X C
14.00 x 12.00 x 6.00
(355.6 x 304.8 x 152.4)
14.00 x 12.00 x 6.00
(355.6 x 304.8 x 152.4)
20.00 x 16.00 x 9.00
(508 x 406.4 x 228.6)
20.00 x 16.00 x 9.00
(508 x 406.4 x 228.6)
24.00 x 20.00 x 9.00
(609.6 x 508 x 228.6)
14.00 x 12.00 x 6.00
(355.6 x 304.8 x 152.4)
14.00 x 12.00 x 6.00
(355.6 x 304.8 x 152.4)
20.00 x 16.00 x 9.00
(508 x 406.4 x 228.6)
20.00 x 16.00 x 9.00
(508 x 406.4 x 228.6)
24.00 x 20.00 x 9.00
(609.6 x 508 x 228.6)
14.00 x 12.00 x 6.00
(355.6 x 304.8 x 152.4)
14.00 x 12.00 x 6.00
(355.6 x 304.8 x 152.4)
20.00 x 16.00 x 9.00
(508 x 406.4 x 228.6)
20.00 x 16.00 x 9.00
(508 x 406.4 x 228.6)
24.00 x 20.00 x 9.00
(609.6 x 508 x 228.6)
10.0 x 8.0 x 6.0
(254.0 x 203.2 x 152.4)
10.0 x 8.0 x 6.0
(254.0 x 203.2 x 152.4)
14.00 x 12.00 x 6.00
(355.6 x 304.8 x 152.4)
20.00 x 16.00 x 9.00
(508 x 406.4 x 228.6)
24.00 x 20.00 x 9.00
(609.6 x 508 x 228.6)
MOUNTING FLANGE DIM.
IN (MM) - D X E X F
14.75 x 10.0 x 15.5
(374.7 x 254.0 x 393.7)
14.75 x 10.0 x 15.5
(374.7 x 254.0 x 393.7)
21.25 x 10.0 x 22.5
(539.8 x 254.0 x 571.5)
21.25 x 10.0 x 22.5
(539.8 x 254.0 x 571.5)
25.25 x 14.0 x 26.5
(641.4 x 355.6 x 673.1)
14.75 x 10.0 x 15.5
(374.7 x 254.0 x 393.7)
14.75 x 10.0 x 15.5
(374.7 x 254.0 x 393.7)
21.25 x 10.0 x 22.5
(539.8 x 254.0 x 571.5)
21.25 x 10.0 x 22.5
(539.8 x 254.0 x 571.5)
25.25 x 14.0 x 26.5
(641.4 x 355.6 x 673.1)
14.75 x 10.0 x 15.5
(374.7 x 254.0 x 393.7)
14.75 x 10.0 x 15.5
(374.7 x 254.0 x 393.7)
21.25 x 10.0 x 22.5
(539.8 x 254.0 x 571.5)
21.25 x 10.0 x 22.5
(539.8 x 254.0 x 571.5)
25.25 x 14.0 x 26.5
(641.4 x 355.6 x 673.1)
10.75 x 6.0 x 11.5
(273.1 x 152.4 x 292.1)
10.75 x 6.0 x 11.5
(273.1 x 152.4 x 292.1)
14.75 x 10.0 x 15.5
(374.7 x 254.0 x 393.7)
21.25 x 10.0 x 22.5
(539.8 x 254.0 x 571.5)
25.25 x 14.0 x 26.5
(641.4 x 355.6 x 673.1)
WEIGHT
LBS (KG)
35.0 (19.90) 4
35.0 (19.90) 4
45.0 (20.41) 2
65.0 (29.48) 2
115.0 (52.16) 2
35.0 (19.90) 4
35.0 (19.90) 4
45.0 (20.41) 2
65.0 (29.48) 2
115.0 (52.16) 2
35.0 (19.90) 4
35.0 (19.90) 4
45.0 (20.41) 2
65.0 (29.48) 2
115.0 (52.16) 2
35.0 (19.90) 4
35.0 (19.90) 4
45.0 (20.41) 4
65.0 (29.48) 2
115.0 (52.16) 2
DESIGN
STYLE
* Units are standard in NEMA 12 hinged enclosures
15
active tracking filtering with surge PrOtectiOn
STF SERIES
Specications
DESCRIPTION 120/208 VAC MODELS 277/480 VAC MODELS 480 VAC MODELS
Input Voltage 0-150/240 Vrms 0-320/520 Vrms 0-520 Vrms
Line Frequency 50/60 Hz
Transient Attenuation Response Time
Mean Time Between Failure (MTBF) > 100,000 Hours (Mil Std. 217F)
Single phase < 30 Amps housed in black, high impact plastic case,
Packaging
Operating Temperature -40°C to +45°C; Derate Linearly to 60% at +70ºC
Load Surge Current Rating
Transient Reduction
Warranty
Minimum of 40dB from 50 kHz through 50 MHz. Attenuation is greater than 50 dB to the surge withstand
capability Ringwave test IEEE C62.41, Category “A” (IEEE Category A Ringwave 6 kV, 200A, 100 kHz)
vacuum impregnated magnetics, epoxy encapsulated.
Single phase > 30 Amps, 480 Vac,
and three phase units housed in NEMA 12 enclosures.
and “B” (IEEE Category B Ringwave 6 kV, 500 A, 100 kHz).
Instantaneous
10m sec: 5 x Nominal
1 sec : 3 x Nominal
5 sec: 2 x Nominal
10 year limited warranty
Dimensional Drawings
F
Design Style 2
16
active tracking filtering with surge PrOtectiOn
F
Design Style 4
STFV PLUS SERIES
e SolaHD STFV Plus Series combines Active Tracking® ltration for low energy noise and surge protection for high energy transients. It continuously tracks the input AC power line responding instantly into action upon detecting extraneous high frequency noise and high voltage transients caused by everyday events such as turning on machinery, motors, or equipment.
ese devices are designed to meet UL 1283 for Electromagnetic Interference Filters. STFV Plus attenuates or reduces the amplitude of high frequency noise to a maximum of 90dB that occurs in a range of 100 kHz to 50 MHz. STFV Plus provides the industry’s best IEEE C62.41 Category “A & B” Ringwave protection.
ey are built to meet your unique requirements, and are available in hardwired, single phase conguration. ey are designed for years of trouble free operation and require little or no operator intervention after installation.
Active Tracking® Filters Plus is one part of a total power quality solution. ey can be used alone or in conjunction with other SolaHD products to solve more complex power quality problems.
Applications
• Branch and Control Panels
• Factory Automation Installations
• Point of Use Industrial Service Equipment
• Programmable Logic Controllers
• Dedicated Industrial and Machine Tools
• Telecommunications and IT Equipment
Features
• Non degrading, series lter/TVSS technology for total durability
• UL surge current capacity – 25,000 amps
• High impact plastic case, epoxy encapsulated enclosure
• Transient protection in all modes (L-N, L-G, and N-G)
• Single phase applications up to 30 amp
• Operating temperature from -40°C to +60°C
• Hardwired connection
• LED power indication
• Ten year limited warranty
17
active tracking filtering with surge PrOtectiOn
Selection Table
STFV PLUS SERIES
CATALOG NUMBER
STFV025-10N
STFV050-10N
STFV075-10N
STFV150-10N
STFV300-10N
STFV025-24L
STFV050-24L
STFV075-24L
STFV150-24L
STFV300-24L
AMPS
2.5
5.0
7.5
15.0
30.0
2.5
5.0
7.5
15.0
30.0
CASE DIM.
IN (MM) - A X B X C
4.00 x 2.88 x 1.81
(101.6 x 73.2 x 46.0)
4.00 x 2.88 x 1.81
(101.6 x 73.2 x 46.0)
4.75 x 4.75 x 2.35
(120.7 x 120.7 x 59.7)
6.25 x 4.75 x 2.35
(158.8 x 120.7 x 59.7)
7.75 x 4.75 x 2.35
(196.9 x 120.7 x 59.7)
4.00 x 2.88 x 1.81
(101.6 x 73.2 x 46.0)
4.75 x 4.75 x 2.35
(120.7 x 120.7 x 59.7)
6.25 x 4.75 x 2.35
(158.8 x 120.7 x 59.7)
7.75 x 4.75 x 2.35
(196.9 x 120.7 x 59.7)
7.75 x 4.75 x 2.35
(196.9 x 120.7 x 59.7)
MOUNTING FLANGE DIM.
IN (MM) - D X E X F X G
SINGLE-PHASE MODELS (120 VAC)
4.38 x 2.12 x 5.31 x 0.19
(111.3 x 53.8 x 134.9 x 4.8)
4.38 x 2.12 x 5.31 x 0.19
(111.3 x 53.8 x 134.9 x 4.8)
5.25 x 3.50 x 6.25 x 0.19
(133.4 x 88.9 x 158.8 x 4.8)
6.75 x 3.50 x 7.75 x 0.19
(171.5 x 88.9 x 196.9 x 4.8)
8.25 x 3.50 x 9.00 x 0.19
(209.6 x 88.9 x 228.6 x 4.8)
SINGLE-PHASE MODELS (240 VAC)
4.38 x 2.12 x 5.31 x 0.19
(111.3 x 53.8 x 134.9 x 4.8)
5.25 x 3.50 x 6.25 x 0.19
(133.4 x 88.9 x 158.8 x 4.8)
6.75 x 3.50 x 7.75 x 0.19
(171.5 x 88.9 x 196.9 x 4.8)
8.25 x 3.50 x 9.00 x 0.19
(209.6 x 88.9 x 228.6 x 4.8)
8.25 x 3.50 x 9.00 x 0.19
(209.6 x 88.9 x 228.6 x 4.8)
NUMBER MIN.
WIRE SIZE
(AWG SUGGESTED)
26 #6 2.5 3.125 1.0 (.45)
22 #6 5 6.25 1.3 (.59)
18 #6 7.5 6.25 2.0 (.91)
14 #8 15 18.75 3.5 (1.59)
10 #8 30 37.5 6.0 (2.72)
26 #6 2.5 3.125 1.3 (.59)
22 #6 5 6.25 2.0 (.91)
18 #6 7.5 9.375 3.5 (1.59)
14 #8 15 18.75 5.8 (2.63)
10 #8 30 37.5 6.0 (2.72)
SCREW
SIZE
FUSE/CIRCUIT BREAKER
AMPACITY
SuggeSt MAX
WEIGHT
LBS (KG)
Dimensions System Design
Series Blocking Inductors smoothing inductors
Shunt Absorbing Component sine wave tracking circuitry
MOV Transient Protection high-energy transient protection line to neutral, line to ground, neutral to ground
Mounting
Dimensions
18
Pulse Capacitor high-frequency noise absorption
active tracking filtering with surge PrOtectiOn
STFV PLUS SERIES
Specications
DESCRIPTION VALUE
Input Voltage
Line Frequency 50/60 Hz
Conguration Single Phase (2 wire + ground)
Response Time < 5 ns
Enclosure High impact plastic case, 94V-0, Vacuum impregnated magnetics, epoxy encapsulated
Fusing External
Status Indication Green LED
Connection/Mounting Type Series/Panel Mount
Operating Temperature -40°C to +60°C at full load
Operating Humidity 0% to 95% Non-condensing
Mean Time Between Failure (MTBF)
Packaging High impact plastic case, vacuum impregnated magnetics, epoxy encapsulated
Peak Surge Current Capability (8 x 20 µs)
Load Surge Current Rating
Frequency Response (Forward Reverse)
Transient Reduction * (IEEE C62.41)
Warranty 10 year limited warranty
120 Vac Models 0-150 Vrms
240 Vac Models 0-275 Vrms
Derate Linearly to 60% at +70ºC
Greater than 100,000 hours (Mil. Std. 217F)
Per Phase 25,000 Amps
Line to Neutral 12,500 Amps
Line to Ground 12,500 Amps
Neutral to Ground 12,500 Amps
10m sec 5 x Nominal
1 sec 3 x Nominal
10 sec 2 x Nominal
100 kHz to 50 MHz 90 dB Max
Typical Category A Ringwave
(6 kV, 200A, 100 kHz)
Typical Category B Ringwave
(6 kV, 500A, 100 kHz)
< 10 volts peak
< 50 volts peak
* All measurements in volts. IEEE test results with no AC applied.
19
active tracking filtering with surge PrOtectiOn
e SolaHD STF Elite DIN Rail Mount Series combines Active Tracking® technology with UL Listed surge protection to protect against the full spectrum of voltage transients and surges. It continuously tracks the input AC power line responding instantly into action upon detecting extraneous high frequency noise and high voltage transients caused by everyday events such as turning on machinery, motors, or equipment.
STFE ELITE SERIES
Features
• Series connected DIN Rail mounted lter
• Durable metal mount clip
UL Listed surge current capacity – 45,000 Amps
• Transient protection in all modes (L-N, L-G, and N-G)
• Single phase applications up to 20 Amp
• Operating temperature from -40°C to +50°C
• Screw terminal connections
- Reliable and convenient screw clamp connections
- Accept 10-16 AWG wire
- Meet IP20 specications for ingress protection
• LED status indication
• Form C contact for remote monitoring
• Five year limited warranty
e STFE Series attenuates or reduces the amplitude of normal mode noise to a minimum of 90dB that occurs in a frequency range of 100KHz to 50MHz, and common mode noise to a minimum of 60dB that occurs in a frequency range of 5MHz to 50MHz. STFE provides the industry’s best IEEE C62.41 Category “A & B” Ringwave protection.
ey are built to meet your unique requirements, and are available in hardwired DIN Rail mount, single phase conguration. ey are designed for years of trouble free operation and require little or no operator intervention after installation.
Applications
• Control Panels
• Factory Automation Installations
• Point of Use Industrial Equipment
• Programmable Logic Controllers
• Dedicated Industrial and Machine Tools Equipment
Selection Table
CATALOG NUMBER
STFE030-10N
STFE050-10N
STFE100-10N
STFE200-10N
STFE030-24L
STFE050-24L
STFE100-24L
STFE200-24L
INPUT VOLTAGE
120 V Single Phase, 2 Wire + Ground
120 V Single Phase, 2 Wire + Ground
120 V Single Phase, 2 Wire + Ground
120 V Single Phase, 2 Wire + Ground
240 V Single Phase, 2 Wire + Ground
240 V Single Phase, 2 Wire + Ground
240 V Single Phase, 2 Wire + Ground
240 V Single Phase, 2 Wire + Ground
20
active tracking filtering with surge PrOtectiOn
STFE ELITE SERIES
Specications
DESCRIPTION
STFEXXX-10N STFEXXX-24L
Input Voltage 120 V (0-150 Vrms) 240 V (0-275 Vrms)
Line Frequency 47 - 63 Hz
Response Time < .5 ns normal mode, <5 ns common mode
Enclosure Fully Enclosed Metal Housing
Fusing Reference Fuse/Circuit Breaker Chart
Status Indication Green LED “OK”/Form C Contact/10 Amps @ 250 Vac or 5 Amps @ 100 Vdc
Connection/Mounting Type DIN Rail Mount
Operating Temperature -40°C to +50°C at full load Derate Linearly to 60% at +70ºC
Weight - lbs (kg) 1.7 lbs (0.70 kg)
Dimensions - in (mm) (H x W x D)
4.88 x 2.56 x 4.56
(124.0 x 65.0 x 116.0)
Operating Humidity 0% to 95% Non-condensing
Per Phase 30,000 Amps
Peak Surge Current Capability
Line to Neutral 20,000 Amps
Line to Ground 10,000 Amps
Neutral to Ground 10,000 Amps
10m Sec 5 x Nominal
Load Surge Current Rating
1 sec 3 x Nominal
10 sec 2 x Nominal
Frequency Response
Normal Mode (Forward-Reverse) 100 kHz to 50 MHz 90 dB Max
Common Mode (Forward-Reverse) 5 MHz to 50 MHz 60 dB Max
Transient Reduction (IEEE C62.41)
Typical Category A Ringwave
(6 kV, 200A, 100 kHz)
Typical Category B Ringwave
(6 kV, 500A, 100 kHz)
< 60 V Peak
<100 V Peak UL 1449
Warranty 5 year limited warranty
Connection Diagram
Line input from source
L/L1
N/L2
GND
LINE
L/L1
N/L2
GND
Relay Contacts
COMNO NC
LOAD
L/L1
N/L2
GND
L/L1
To load or
N/L2
GND
To remote indication if needed
equipment protect
active tracking filtering with surge PrOtectiOn
21
e rapid development of automated controls, telecommunications and re/security systems has made it imperative to have properly coordinated low-voltage protection. Modern networked industrial facilities require error free transmission of information for maximum productivity and integrity of data.
e SolaHD STC series protects all susceptible low­voltage cable routes entering a facility and at key points within the building. ese devices can be used as part of a multi-stage protection strategy which involves clamping the initial high-energy impulse, ltering any remaining noise or transients to the PLC or sensitive equipment and nally, protecting the Data/Signal lines entering and leaving the control panel. Modern, networked industrial facilities require error free transmission of information for maximum productivity and data integrity.
e hybrid design of these Data/Signal Line surge suppressors allows them to respond quickly with high energy absorption. ese units are available in a variety of application specic voltage levels and packaging congurations. e STC series is used to protect network signal lines entering or leaving control panels including PLCs, universal remote I/O, DeviceNet
TM
and Data Highway Plus.
STC SERIES
Low Voltage - Data/Signal, STC Series
SERIES APPLICATION
STC-POE
STC-DRS
STC-642
STC-CCTV
22
Data/signal line surge protection
Power-over-Ethernet, Category 5 and Category 6
DIN Rail mountable, single-pair surge protection
Two-pair data/signal protection
High-frequency coaxial protection for head and camera ends
STC-POE SERIES
e SolaHD STC Power-over-Ethernet (PoE) series is designed to work on Category 5 PoE transmission lines as well as Category 6 applications. ey feature both female to female and male to female RJ-45 connection options for ease of installation.
Power-over-Ethernet is a technology for wired Ethernet LANs (Local Area Networks) that allows the electrical current to be carried by the data cables rather than power cords. is minimizes the number of wires that must be strung in order to install the network. e result is lower cost, less downtime, easier maintenance and greater installation exibility than with traditional wiring.
e STC PoE series is ideally suited to protect expensive equipment and critical communication/data transfer from internally generated transients and noise.
Features
• Exceeds CAT 5 PoE & 6 transmission values
• Applications up to 60 Vdc @ 300 mA
• ree year limited warranty
PoE allows users to power devices over Ethernet cabling. Power and networking is provided over a single cable. PoE has tremendous advantages in industrial applications. e ease of combining signal and power in a single Ethernet cable connection is contributing to the already rapid evolution of Ethernet-based
STC-POE-65FF
Features
• Single use design
• 60 Vdc @ 300 mA continuous
• Cost eective protection
industrial control systems. Category 5e and Category 6 commonly known as Cat5e and Cat6 are the most widely used Ethernet connectivity methods on the market today. Cat5e and Cat6 are dened in ANSI/ TIA/EIA 568-B standard for Unshielded Twisted Pair Cabling.
Selection Table
CATALOG NUMBER DESCRIPTION
STC-P0E-65FF
STC-CAT6-P0E-I
STC-C6-MP4
Female to Female Connector
Female to Female Connector with isolated ground
CAT 6 PoE Mounting Plate
STC-CAT6-POE-I
Features
• Hybrid PTC (positive temperature coecient) resettable fuse -
up to 5,000 times
• 60 Vdc @ 750 mA continuous
• Isolated ground available
• 10kA peak surge current
• Premium protection
Specications
DESCRIPTION STC-P0E-65FF STC-CAT6-POE-I
Mode of Protection
DC Breakover Voltage 60 Vdc
Insertion Loss < .1 dB
Certied Transmission Speeds 10baseT, 100baseT, 1000baseT
Peak Surge Energy 300 Watt 750 Watt
Response Time <1 ns
Connectors RJ-45 (Female - Female)
Dimensions - in (mm) 2.30 x 1.00 x .80 (58.4 x 25.4 x 20.3) 5.40 x 1.60 x 1.70 (137.2 x 40.7 x 43.2)
Warranty 3 year limited warranty 5 year limited warranty
Normal Mode (L-L)
All Lines (1-8) Protected
All Lines (1-8) Protected (L-L) and (L-G)
Signal High-Low; High-Ground; Low-Ground
23
Data/signal line surge protection
Using three-stage hybrid technology, this DIN Rail mountable, single pair, surge suppressor attenuates over-voltage transients with gas tubes and silicon avalanche components while resetable fuses (PTCs) mitigate sneak currents. e PTC increases resistance by several orders of magnitude when over-currents exceed safe levels. A normal state resumes when over­currents are removed. e ability to self-restore in this manner signicantly increases suppressor performance and survivability.
e STC-DRS Series mounts onto a standard 35 mm industrial DIN rail. ere are three Field Side and three Electronics Side screw terminals. One is reserved for a shield. ree electrically tied ground terminals are provided for grounding the unit to building-approved ground. e shield is isolated from ground.
Features
• Low-Voltage data surge protection
• ree-Stage hybrid technology
• Sneak/Fault current protection with
resetable fuses (PTCs)
• Low prole packaging
• Easy installation
• Fits standard 35 mm DIN Rail
• Fast response time <1 nanosecond
• Five year limited warranty
STC-DRS SERIES
Dimensions
Notes: ese protectors are intended for indoor use on communication loop circuits that have been isolated from the Public Switch Telephone Network.
Selection Table
CATALOG NUMBER
STC-DRS-232
STC-DRS-036
STC-DRS-060
24
Data/signal line surge protection
MAX PEAK
SIGNAL VOLTAGE
15 22 >100 10KA 1500 150ma 5 Ω
30 36 >100 10KA 1500 150ma 5 Ω
52 60 >100 10KA 1500 150ma 5 Ω
NOMINAL
BREAKDOWN
VOLTAGE
e communication loop circuits shall not be exposed to accidental contact with the electric light or power conductors. e protectors shall be installed per the applicable requirements of the National Electric Code, ANSI/NFPA 70.
MAX CURRENT
1P 10X1000 MS
(OCCURRENCES)
PEAK CURRENT
8X20 MS
TYP. CAP
(PF)
MAX.
CONTINUOUS
CURRENT
NOMINAL
SERIES
RESISTANCE
STC-642 SERIES
e STC-642 series of surge suppressors are dual pair (four wire) modules using three-stage hybrid technology. is module addresses over voltage transients with gas tubes and silicon avalanche components. In addition, sneak and fault currents are mitigated with resetable fuses (PTCs). e PTCs increase resistance several orders of magnitude when over currents exceed safe levels. A normal state resumes when over currents are removed. e ability to self restore in this manner signicantly increases suppressor performance and survivability.
e STC-642 card edge module is gold-plated, double sided and is designed to mate with the STC-642 gold­plated female terminal connector (sold separately). When snapped together, the data circuits pass thru the protector in a serial fashion from the four Field Side terminals to the four Electronics Side terminals. Terminals 1 or 10 of the STC-PCB1B must be attached to building approved ground.
Application
• Intended for indoor use on communication loop
circuits which have been isolated from the Public Switch Telephone Network.
• RS232 applications used with STC642-020 and STC-PCB1B
• 4-20 ma signal applications used with STC642-
036 and STC-PCB1B
• For use in service capable of supplying less than
150 milliamperes continuously.
Features
• Lightning protection for low voltage data
• Signal lines
• ree-stage protection
• Sneak/fault current protection
• Resetable solid-state fuses - PTCs
• Low capacitance option for high speed data
• Plug-in module / Requires PCB1B base
• Hybrid design of includes series resistance
• Fast response time
• Five year limited warranty
Selection Table
CATALOG NUMBER
STC642-020
STC642-036
STC-PCB1B
STC-FM4-DRC
20 Volt Clamp
36 Volt Clamp
Base for all STC-642 models. Designed to accommodate up to 10 AWG wire. It oers Flat/ Phillips screws and can be mounted using 2 #6 size screws. Must be ordered separately.
Optional DIN Rail Mounting Clip for STC-PCB1B
DESCRIPTION
Specications
DESCRIPTION STC642-020* STC642-036*
Peak Surge Current (10 times)
Life Expectancy
Response Time <1ns
Voltage Clamp 20 36
Technology SAD Hybrid
Resistance 5 (typical)
Capacitance (typical) 1500pf
Operating Temperature -40
Weight - oz 2
Dimensions H x W x L ­in (mm) (STC-642 & PCB1B)
Warranty 5 year limited warranty
*Part number STC-PCBIB sold separately
8x20 s (2000A) .. >100 occurrences
2.05 x 1.00 x 2.40 (52.1 x 25.4 x 61.0)
8x20 s .. 10kA
10x700 s 500A per line
10x700 s (400A)
o
C to +85oC
25
Data/signal line surge protection
Wiring Diagram (PIN Assignments)
STC-642 SERIES
2.16
(55.0)
Ground Terminal 1 or 10 (internally tied together) to building approved ground. The STC-PCB1B accommodates 24 to 10 AWG wire.
2.41
(61.2)
0.12 (3.0)
0.49 (12.4)
2.40
(61.0)
Top View
26
Data/signal line surge protection
0.80 (20.3)
Side View
STC-CCTV SERIES
e STC-CCTV Series is tailored specically to CCTV, data, audio and cable applications. ese units are single Coax Surge Protective Devices implementing three-stage hybrid technology. ey address overvoltage transients with a primary gas tube, and secondary silicon avalanche components. Over-currents (e.g. sneak and fault currents) are mitigated with solid-state resetable fuses (PTCs). e STC-CCTV units are designed in accordance with NFPA 780 (2004 Edition) requirements, with up to 20kA of surge current capability. e STC-CCTV-75I model has an isolated ground and is recommended for use at the camera end.
Applications
• CCTV Head End
• CCTV Camera End
Features
• Hybrid, three-stage technology
• Sneak/fault current protection
• Low insertion loss
• Shielded case
• Five year limited warranty
Specications
DESCRIPTION STC-CCTV-75 STC-CCTV-75I
Operating Voltage 5
Clamping Voltage 6
Frequency Range 0 to 20 MHz
Equipment Location
Rated Load Current 0.35 amperes
Topology 2-port Series
STC Technology
Modes of Protection Signal to Ground
Nominal Discharge Current per Mode
Maximum Discharge Current per Mode
EMI Attenuation < 0.1 dB at 20 MHz
VSWR < 1.2
Continuous Power 0.72 Watts
Operating Humidity
Operating & Storage Temperature
Input & Output Connection Type
Mounting Flange
Enclosure Type Metal
Certications
Warranty 5 year limited warranty
IEEE Category C, and Category B
Secondary Stage: Silicon Avalanche Components
Compliant for Communication Protectors
Primary Stage: Gas Tubes,
ird Stage: resetable fuses (PTCs)
10.0 kA
20.0 kA
0-95 % Non-condensing
o
-40
C to +85oC
BNC, 50 Ohm
UL 497B Pending, NFPA 780 (2004)
27
Data/signal line surge protection
SolaHD is our premium line of power­conversion and power quality solutions products under Appleton Group, a business unit of Emerson Industrial Automation.
Emerson Industrial Automation brings integrated manufacturing solutions to diverse industries worldwide. Our comprehensive product line, extensive experience, world-class engineering and global presence enable us to implement solutions that give our customers the competitive edge.
For over 150 years, our electrical product brands have been providing a rich tradition of long-term, practical, high quality solutions with applications ranging from the construction and safe operation of petrochemical and process plants to providing quality power that precisely controls automotive robotic production.
Engineers, distributors, contractors, electricians and site maintenance professionals around the world trust Emerson Industrial Automation brands to make electrical installations safer, more productive and more reliable.
Appleton Group is organized into three focused businesses that provide distributors and end-users expert knowledge and excellent service.
Electrical Construction Materials
This group is made up of the Appleton, Nutsteel and O-Z/Gedney brands. They manufacture a broad range of electrical products including conduit and cable
ttings, plugs and receptacles, enclosures
and controls, conduit bodies and industrial and hazardous lighting. Whether the application is hazardous location, industrial or commercial, the electrical construction materials group has the products to meet your needs.
Power Quality Solutions
The SolaHD brand offers the broadest power quality line, including uninterruptible power supplies, power conditioners, voltage regulators, shielded transformers, surge protection devices and power supplies.
Heating Cable Systems
This group is made up of the EasyHeat and Nelson brands. They offer a broad range of electrical heating cable products for residential, commercial and industrial applications.
Asia/Pacic
+ 65.6891.7600
Australia + 61.3.9721.0348
Brazil — São Paulo/SP + 55.11.2122.5777
Brazil — Camaçari/BA + 55.71.3623.2028
Canada + 1.888.765.2226
China + 86.21.3418.3888
Europe + 33.3.2254.1390
Mexico/Latin America + 52.55.5809.5049
Middle East/Africa/India + 971.4.811.8100
United States + 1.800.621.1506
Appleton Grp LLC 9377 W. Higgins Road Rosemont, IL 60018
1.800.377.4384 solahd.com
Appleton Grp LLC d/b/a Appleton Group. The Appleton, O-Z/Gedney, SolaHD, EasyHeat, Nelson and Emerson logos are registered in the U.S. Patent and Trademark Ofce. EasyHeat, Inc. is a wholly owned subsidiary of Appleton Grp LLC. All other product or service names are the property of their registered owners. © 2014, Appleton Grp LLC. All rights reserved.
Loading...