This manual provides general information and procedures for using the Roxar Sacrificial
Probe, and is intended for use by qualified personnel. The information presented in this
manual is not specific to a particular application, installation or process, and must be
evaluated on a case-by-case basis by the operator. Contact Emerson for more information.
1.1Conformity to standards
This document has been issued in compliance with the most common international
standards for user manual documentation.
1.2Warnings
WARNING
The instructions and procedures described in this document may require special
precautions to ensure the safety of the personnel performing the operations. Information
that potentially raises safety issues is indicated by a warning symbol followed by a safety
message.
1.3Acronyms and definitions
AcronymDefinition
PPEPersonal Protective Equipment
MSDSMaterial Safety Data Sheet
1.4Personnel qualifications and safety
You must read and follow all instructions, warnings and cautions to avoid personal injury
or damage to property during system operation. Emerson is not responsible for damage or
injury resulting from unsafe use of the product, lack of maintenance, incorrect installation
of equipment, or system operation. Contact Emerson if you have questions about any
applications and safety precautions described in this manual.
Ensure that operators working on the equipment are following the end-user guidelines on
the use of protective equipment including, but not limited to the following:
• Safety helmet/hard hat
• Steel-toed shoes
• Safety glasses
• Working gloves (suitable for mechanical operations)
• Chemical resistant latex gloves, or equivalent
www.Emerson.com/Roxar5
Page 6
IntroductionUser Manual
March 2019ROXA20034733
• Long sleeved fire-retardant shirt and fire-retardant trousers, or full-length fire-
retardant coveralls
Additional Personal Protective Equipment (PPE) may be required depending on facility
requirements and Material Safety Data Sheet (MSDS) requirements. Failure to do so may
result in personnel injury.
1.5Warranty restrictions
You must visually inspect all components for shipping damage and notify the carrier, if you
find any shipping damage. Shipping damage is not covered by the warranty. The carrier is
responsible for all repair and replacement costs resulting from shipment damage.
1.6Additional documentation and resources
• ROX000295904 - Roxar Mechanical Retrieval Tool User Manual
• ROX000337352 - Roxar Hydraulic Retrieval Tool User Manual
1.7Assistance
The Roxar Global Service Centre is organized through a network of service centers
worldwide, and supports all service requirements or technical queries.
For the Product Support Help Desk, contact Roxar.GSC@Emerson.com.
6www.Emerson.com/Roxar
Page 7
User ManualTechnical description
ROXA20034733March 2019
2Technical description
The term "probe" is collective noun for the equipment used to provide information relating
to process changes and their effect on metal loss from corrosion and/or erosion. There are
different types of probes with different measurement techniques.
This manual describes the Roxar Sacrificial Probe. Contact Emerson for more information
on other types of Roxar probes.
2.1Roxar Sacrificial Probe
The early detection of sand production in fields is one of the biggest challenges faced by
oil and gas companies. High sand production can cause damage to pipes and instruments,
pose a safety risk, and be very costly for operators. Therefore, the early warnings and
detection of erosion is crucial for operators. The Roxar Sacrificial Sand Probe is used to
provide information when sand erosion has exceeded the element thickness of the probe,
in order to avoid erosion damage, or control sand production.
The Roxar Sacrificial Probe is an intrusive sand probe that consists of a hollow tube and a
holder. The Roxar Sacrificial Probe is inserted into a high velocity flow, and an indication is
given by a pressure gauge, or a pressure transmitter, once the pressure has penetrated the
sacrificial tube due to the wear caused by sand and other particles in the flow.
The Roxar Sacrificial Probe can be installed in two ways:
• The Roxar Sacrificial Probe (Retrievable) is installed in an tee-type 2 in access fitting.
• The Roxar Sacrificial Probe (Non-retrievable ) is installed in taps welded directly onto
the pipe or vessel (welding bosses or threadolets).
Note
If the Roxar Sacrificial Probe is installed in an tee-type 2 in access fitting system, the probe
can be retrieved and replaced without any interruptions to the mainstream flow, or the
need to depressurize the pipe.
The sensing element of the Roxar Sacrificial Probe consists of a tube made from corrosion
resistant material. The tube is closed at one end and threaded at the other end to mate
with the probe nut. The nut enables the Roxar Sacrificial Probe to be attached to a solid
plug and used in a Roxar Access Fitting Assembly with a tee.
Emerson recommends placement of the probe within the pipeline, so that the midpoint of
the sacrificial tube is placed approximately 60% into the pipeline diameter (ID). This
placement allows for maximum theoretical sand impingement at center of line where the
sand concentration and flow rates are often greatest. It also allows for heavier suspended
participles flowing slightly lower in the flow stream to also contact the sacrificial tube.
If there is sufficient flow velocity, the effect of sand and solids erodes through the
Sacrificial Probe sensing element over time, and exposes the sealed system to the working
pressure of the line. The pressure passes through a valve assembly and is registered by the
pressure gauge.
The Non-retrievable sacrificial system is available in a fixed configuration and can only be
removed and replaced when the process line is not exposed to pressure. The Retrievable
www.Emerson.com/Roxar7
Page 8
Technical descriptionUser Manual
March 2019ROXA20034733
sacrificial system can be removed and replaced under full operation, with the support of
the Roxar Mechanical Retriever Tool or the Roxar Hydraulic Retriever Tool.
Figure 2-1 shows the different ways in which the Roxar Sacrificial Probe can be installed.
Figure 2-1: Roxar Sacrificial Probe Assembly
A. Sacrificial Probe Assembly (Retrievable) mounted in a tee-type flareweld mechanical
access fitting
B. Sacrificial Probe Assembly (Retrievable) mounted in a tee-type flanged hydraulic access
fitting
C. Sacrificial Probe Assembly (Non-retrievable) mounted in a threadolet
8www.Emerson.com/Roxar
Page 9
User ManualTechnical description
ROXA20034733March 2019
2.2Main components
The Roxar Sacrificial Probe (Retrievable) system in a 2 in tee-type hydraulic flanged access
fitting consists of the following parts:
Figure 2-4 shows the parts of a Roxar Sacrificial Probe (Non-retrievable).
A. Pressure gauge
B. Shut-off valve
C. Threadolet or welding boss
D. Sacrificial Probe
www.Emerson.com/Roxar11
Page 12
Technical descriptionUser Manual
March 2019ROXA20034733
2.3Specifications and dimensions
SpecificationsValue
Probe body materialStainless Steel AISI 316L/316 (dual certification)
Diameter of sacrificial tubeØ16 mm
Wall thickness of sacrificial tube1 mm
Probe lengthFrom 80 mm to 390 mm (depending on the
type of probe)
Probe installation in pipeInstalled approximately 60% into the pipe
diameter (ID)
Maximum operating temperature204 °C
Maximum operating pressure6,000 psi
Mechanical interface½ in NPT (retrievable) and ¾ in NPT (non-
retrievable)
12www.Emerson.com/Roxar
Page 13
User ManualPreparation
ROXA20034733March 2019
3Preparation
This section describes the prerequisites and preparations (including observations) to be
carried out before installing the different parts of the equipment. The instructions cover
the following equipment:
• Roxar Sacrificial Probe (Retrievable and Non-retrievable)
• Injection nut
You can install the Roxar Sacrificial probe in two ways:
• Manually, by using hand tools before the system starts up, or during shut down when
the line or vessel is empty and depressurized.
• By using a special retrieval tool during full operational conditions of the system. For
more information, see Additional documentation and resources.
Note
The guidelines provided in this manual are based on the 2 in hydraulic or mechanical
system that is being operated. If you are using a retrievable system, make sure you read
and follow the instructions in the user manual of your system, including the
recommendations for spare parts.
3.1Tools
Retrievable Probe with tee-type 2 in access fitting system
In addition to the tools listed in the manuals for the applicable Retriever Tool (mechanical
or hydraulic), you will need a 23 mm spanner to assemble the Sacrificial Probe into the
injection nut.
WARNING
DANGER TO PERSONNEL AND EQUIPMENT. Make sure that the length of retriever tool
available for the operation is compatible with the length of the Sacrificial Probe.
Non-retrievable Probe
You will need a 23 mm spanner to assemble the Roxar Sacrificial Probe into the pipe tap. A
set of two adjustable spanners is also required to assemble the shut-off valve and the
pressure gauge (or pressure transmitter, if applicable).
WARNING
DANGER TO PERSONNEL AND EQUIPMENT. Installation or replacement of a nonretrievable probe requires a depressurized, drained and ventilated pipe or vessel.
www.Emerson.com/Roxar13
Page 14
PreparationUser Manual
March 2019ROXA20034733
3.2Consumables
You do not need any additional consumables for non-retrievable sacrificial probes that are
installed in a welding boss or threadolet.
If the probe is installed in a retrievable type 2 in access fitting, you will need the spare parts
that are listed under operational instructions for the applicable retriever tool (mechanical
or hydraulic).
In addition, a new probe and the following spares shall be available:
Figure 3-1: Consumables for Roxar Sacrificial Probe Nut (Retrievable)
A. Position 1
B. Position 2
C. Position 1
3.2.1
14www.Emerson.com/Roxar
Part numbers for consumables
PositionDescriptionMaterialPart number
Pos.1Backup ringPTFEROX000323092
Pos.2O-ringVITON 75ROX000278467
FKM938ROX000323093
HNBR90ROX000342560
ELAST-O-LIONROXA20035755
FR25/90ROX000339898
FKM 75ROXA20035756
Page 15
User ManualOperating instructions
ROXA20034733March 2019
4Operating instructions
Introduction
Generally, the Roxar Sacrificial Probe is operated only during the replacement of probe
itself. Due the nature of the sensor, a local indication is provided by the pressure gauge (or
a signal is sent to control room, if a pressure transmitter is applied) once the probe tube is
eroded. That means if 1 mm of metal loss is eroded, the rate can be calculated by dividing
the thickness of the tube (1 mm) by the time that elapsed since the probe was exposed to
flow and until the indication came on the pressure gauge.
It is important to highlight the importance of replacing the Sacrificial Probe as soon as
there is metal loss due to erosion, which must be taken into consideration for assessment
of pipe integrity and future production of the actual well.
4.1Roxar Sacrificial Probe (Retrievable)
Note
To replace a Roxar Sacrificial Probe (Retrievable) installed in a 2 in access fitting, refer to
the user manuals for the applicable retriever tool and 2 in access fittings.
After you have retrieved the plug, injection nut and probe, replace the sealing device at
the plug, the O-ring and the back-up ring at the injection nut and the Sacrificial Probe.
The Sacrificial Probes are equipped with NPT threads. This means the threads have a
tapered design, and in most cases that is enough to seal the connection. In order to
prevent spiral leakage and avoid galling, Emerson recommends that you use some type of
sealant (tape or paste) and apply the sealant to the male thread only.
When using the tape sealant, wrap the threads in a clockwise motion starting at the first
thread. As the layers are applied, work towards the imperfect (vanishing) thread. If the
system that the connection being made to cannot tolerate foreign matter, leave the first
thread exposed and apply the tape sealant as outlined above.
When using paste sealant, apply to the threads with a brush, using the brush to work the
sealant into the threads. Apply enough sealant to fill in all the threads all the way around.
Follow the instructions on retrieval procedure to install the probe into the pipe.
4.2Roxar Sacrificial Probe (Non-retrievable)
To replace a Roxar Sacrificial Probe (Non-retrievable), you must first depressurize and drain
the pipe. Once the pipe is confirmed to be depressurized and drained, unscrew the
pressure gauge (or pressure transmitter), the shut-off valve and the eroded probe.
The Sacrificial Probes are equipped with NPT threads. This means the threads have a
tapered design, and in most cases that is enough to seal the connection. In order to
prevent spiral leakage and avoid galling, Emerson recommends that you use some type of
sealant (tape or paste) and apply the sealant to the male thread only.
When using the tape sealant, wrap the threads in a clockwise motion starting at the first
thread. As the layers are applied, work towards the imperfect (vanishing) thread. If the
www.Emerson.com/Roxar15
Page 16
Operating instructionsUser Manual
March 2019ROXA20034733
system that the connection being made to cannot tolerate foreign matter, leave the first
thread exposed and apply the tape sealant as outlined above.
When using paste sealant, apply to the threads with a brush, using the brush to work the
sealant into the threads. Apply enough sealant to fill in all the threads all the way around.
Install the new probe into the existing pipe tap, followed by the shut-off valve and pressure
gauge (or pressure transmitter).
16www.Emerson.com/Roxar
Page 17
User ManualMaintenance
ROXA20034733March 2019
5Maintenance
The Roxar Sacrificial Probe does not require any maintenance during normal operational
conditions.
Emerson recommends limited routine inspections to ensure that there are no visual
damages on pressure gauges, covers, shut-off valves and access points.
WARNING
DANGER TO PERSONNEL AND EQUIPMENT. Do not remove the pressure gauge or the
pressure transmitter with the shut-off valve on its open position, even if the probe is still
sealed, and the pressure indication is zero.
The Emerson logo is a trademark and service mark of Emerson Electric Co. Roxar is a trademark of
Roxar ASA. All other marks are property of their respective owners.
Roxar supplies this publication for informational purposes only. While every effort has been made to
ensure accuracy, this publication is not intended to make performance claims or process
recommendations. Roxar does not warrant, guarantee, or assume any legal liability for the accuracy,
completeness, timeliness, reliability, or usefulness of any information, product, or process described
herein. All sales are governed by our terms and conditions, which are available on request. We
reserve the right to modify or improve the designs or specifications of our products at any time
without notice. For actual product information and recommendations, please contact your local
Roxar representative.