Emerson Rosemount 0065, Rosemount 0185 Quick Start Manual

Page 1
Quick Start Guide
00825-0200-2654, Rev BC
April 2015
Rosemount 0065/0185 Sensor Assembly
Page 2
Quick Start Guide
April 2015
This guide provides basic guidelines for Rosemount 0065 and 0185 Sensor models. It does not provide instructions for configuration, diagnostics, maintenance, service, troubleshooting, Explosion-proof, Flameproof, or intrinsically safe (I.S.) installations.
If the Rosemount 0065 or 0185 Sensor was ordered assembled to a Rosemount temperature transmitter, see the appropriate Quick Start Guide for information on configuration and hazardous locations certifications.
WARNING
Explosions could result in death or serious injury.
Installation of this transmitter in an explosive environment must be in accordance with the appropriate local, national, and international standards, codes, and practices.
Conduit/cable entries
Unless marked, the conduit/cable entries in the transmitter housing use a
form. Entries marked “M20” are M20 x 1.5 thread form. On devices with multiple conduit entries, all entries will have the same thread form. Only use plugs, adapters, glands, or conduit with a compatible thread form when closing these entries.
1
/2-14 NPT thread
Contents
Wiring Diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Sensor Assembly Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Product Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
2
Page 3
April 2015
Red
White
White
Red
Red Red
Green
Blue Blue
Black
3
4
1
6
Red
Red
White
White
6
1
3
4
1
2
3
4
5
6
4
5
6
1
2
3
Red
Red
White
Red
Red
White
Wiring Diagrams
Figure 1. Series 65 RTD Lead Wire Configuration
Series 65 RTD flying leads and spring-loaded adapter-termination codes 0, 1, or 3 only
Single element Dual element
Quick Start Guide
Series 65 RTD terminal block termination code 2 and 4
Single element Dual element
Note
For 3-wire systems use one white and two red leads. Do not connect the white leads. Insulate or terminate the unused white lead in a manner that prevents shorting to the ground. For 2-wire systems, connect both sets of leads.
3
Page 4
Quick Start Guide
3
1
1 (-)
3(+)
1
3
46
4(+)
6(-)
1(-)
3(+)
Figure 2. Series 185 Thermocouple Lead Wire Configuration
Series 185 RTD thermocouple terminal block
Single element Dual element
April 2015
Table 1. Series 185 Thermocouple Characteristics
Limits of error
interchangeability
DIN EN 60584-2
Tol er an ce
class
Typ e
J
K
N
E
T
Alloys
(wire color)
Fe (+ black),
CuNi (- white)
NiCr (+ green),
NiAl (- white)
NiCrSi (+ pink),
NiSi (- white)
Ni-Cr (+violet),
Cu-NI (-white)
Cu (+brown),
Cu-Ni (-white)
Sheath material Temp. range (°C)
1.4541 (321 SST) -40 to 375, 375 to 750 1.5 °C, 0.004 t 1
2.4816 (Inconel 600) -40 to 375, 375 to 1000 1.5 °C, 0.004 t 1
2.4816 (Iconel 600) -40 to 375, 375 to 1000 1.5 °C, 0.004 t 1
1.4541(321 SST) -40 to 375, 375 to 800 1.5 °C, 0.004t 1
1.4541 (321 SST) -40 to 125, 125 to 350 0.5 °C, 0.004t 1
Note
To distinguish the two sensors in Dual 185 Sensors (flying lead or spring loaded styles), the lead wires of one sensor will be longer than the other sensor.
4
Page 5
April 2015
248
644
Head or field mount tran sm itte rs IP68 or IP65 connection heads
Sensor with flying leads, terminal block, or spring-loaded adapter
Extensions
644 with LCD meter
3144
40 mm
25 mm
L
16 mm
N★★
N★★
N★★
L
L
★★ N dimension measures from thread
engagement point.
11 mm
11 mm
Sensor Assembly Dimensions
Sensor assembly without thermowell
Quick Start Guide
5
Page 6
Quick Start Guide
248644
IP68 or IP65, connection heads
Sensor with flying leads or terminal block
Threaded and flanged tubular thermowells
644 with LCD meter
40 mm
Head or field mount transmitters
N
U
U
N
25 mm
NAMUR NAMUR
★★ For straight threading, N
dimension references bottom of hex. For tapered threading, N dimension references thread engagement point (bottom of thread).
U
N
U
GB GN
★★
★★
★★
Tubular thermowell sensor assembly
April 2015
6
Page 7
April 2015
Sensor with flying leads, terminal block, or spring-loaded adapter
Weld-in, threaded or flanged barstock thermowells
* The 644 is available with or without
a LCD display.
3144
Stand-alone extensions
248644
IP 68 or IP 65 connection heads
644 with LCD meter
40 mm
Head or field mount transmitters
11 mm
L
11 mm
16 mm
N★★
11 mm
11 mm
60 mm★★★
U
U
U
60
mm
L
L
★★ N dimension measures from
thread engagement point.
★★★ This dimension is 80 mm for
1500# and 2500# flanges.
N★★
N★★
25 mm
T
U
40 mm
U
60
mm
Barstock thermowell sensor assembly
Quick Start Guide
7
Page 8
Quick Start Guide
Product Certifications
European Directive information
A copy of the EC Declaration of Conformity can be found at the end of the Quick Start Guide. The most recent revision of the EC Declaration of Conformity can be found at www.emersonprocess.com.
Hazardous locations certifications
USA
E5 FM Explosion-proof and Dust-Ignition-proof
Certificate: 0R7A2.AE Standards used: FM Class 3600: 2011; FM Class 3611: 2004; FM Class 3615: 2006; FM
Class 3810: 2005; ANSI/NEMA Markings: XP CL I, Div 1, GP B, C, D; DIP CL II/III, Div 1, GP E, F, G; T6(-50 °C ≤ Ta ≤ +155 °C); Type 4X
®
- 250: 1991
April 2015
Canada
E6 CSA Explosion-proof and Dust-Ignition-proof
Certificate: 1063635 Standards used: CSA C22.2 No. 0-M91; CSA C22.2 No. 25-1966; CSA C22.2 No. 30-M1986; CSA C22.2 No. 94-M91; CSA C22.2 No. 142-M1987; CSA C22.2 No. 213-M1987 Markings: XP CL I, Div 1, GP B, C, D; DIP CL II/III, Div 1, GP E, F, G; CL I, Div 2, GP A, B, C, D; (-50 °C ≤ Ta ≤ +85 °C)
Europe
E1 ATEX Flameproof
Certification number: FM12ATEX0065X Standards Used: 60079-0:2012; EN60079-1:2007 Markings: II 2 G Ex d IIC T6...T1 Gb, T6(-50 °C ≤ Ta ≤ +40 °C), T5...T1 (-50 °C ≤ Ta ≤ +60 °C), 1180
Special Conditions for Safe Use (X):
1. See certificate for ambient temperature range.
2. The non-metallic label may store an electrostatic charge and become a source of ignition in Group III environments.
3. Guard the LCD cover against impact energies greater than 4 joules.
4. Consult the manufacturer if dimensional information on the flameproof joints is necessary.
5. A suitable certified Ex d or Ex tb enclosure is required to be connected to temperature probes with Enclosure option "N".
6. Care shall be taken by the end user to ensure that the external surface temperature on the equipment and the neck of DIN Style Sensor probe does not exceed 130 °C.
8
Page 9
April 2015
I1 ATEX Intri nsic Safety
Certificate: IBExU03ATEX1066X Standards Used: EN 60079-0:2012, EN 6079-11:2012, EN 60079-26:2007 Markings: II 1 G Ex ia IIC T6; II 1/2 G Ex ia IIC T6; II 2 G Ex ia IIC T6; 1180
Special Conditions for Safe Use (X):
1. The installation and the operation of the temperature sensors has to be carried out according to the requirements of the operating instructions.
2. The maximum permissible temperatures of the medium are dependent on the electric output of the supply in case of failure.
3. With maintenance of the collar-tube distance have to be guaranteed the maximum permissible ambient temperatures.
4. The maximum ambient temperature for use in Category 1 G is 60 °C.
N1 ATEX Type n
Certificate: BAS00ATEX3145 Standards used: EN 60079-0:2012, EN 60079-15:2010 Markings: II 3 G Ex nA IIC T5 Gc (-40 °C ≤ Ta ≤ +70 °C); 1180
ND ATE X Dust
Certification number: FM12ATEX0065X Standards Used: EN 60079-0:2012; EN 60079-31: 2009 Markings: II 2 D Ex tb IIIC T130 °C Db (-40 °C ≤ Ta ≤ +70 °C); 1180
Quick Start Guide
Special Conditions for Safe Use (X):
1. See certificate for ambient temperature range.
2. The non-metallic label may store an electrostatic charge and become a source of ignition in Group III environments.
3. Guard the LCD cover against impact energies greater than 4 joules.
4. Consult the manufacturer if dimensional information on the flameproof joints is necessary.
5. A suitable certified Ex d or Ex tb enclosure is required to be connected to temperature probes with Enclosure option “N”.
6. Care shall be taken by the end user to ensure that the external surface temperature on the equipment and the neck of DIN Style Sensor probe does not exceed 130 °C.
International
E7 IECEx Flameproof
Certificate: IECEx FMG 12.0022X Standards Used: be IEC60079-0:201, IEC60079-1:2007-04 Markings: Ex d IIC T6...T1 Gb, T6(-50 °C ≤ Ta ≤ +40 °C), T5…T1(-50 °C ≤ Ta ≤ +60 °C)
Special Conditions for Safe Use (X):
1. See certificate for ambient temperature range.
2. The non-metallic label may store an electrostatic charge and become a source of ignition in Group III environments.
3. Guard the LCD cover against impact energies greater than 4 joules.
4. Consult the manufacturer if dimensional information on the flameproof joints is necessary.
9
Page 10
Quick Start Guide
5. A suitable certified Ex d or Ex tb enclosure is required to be connected to temperature probes with Enclosure option "N".
6. Care shall be taken by the end user to ensure that the external surface temperature on the equipment and the neck of DIN Style Sensor probe does not exceed 130 °C.
Brazil
E2 INMETRO Flameproof
Certificate: NCC 12.1147 X Standards used: ABNT NBR IEC 60079-0: 2008; ABNT NBR IEC 60079-1: 2009 Markings: Ex d IIC T6...T1 Gb IP66W (-40 °C ≤ Ta ≤ +65 °C)
Special Conditions for Safe Use (X):
1. For information on the dimensions of the flameproof joints the manufacturer shall be
contacted.
2. Special care must be taken to ensure that the connection head temperature does not
exceed 85 °C, when thermocouples or RTDs are assembled with transmitters listed in Table 2 of certificate number NCC 12.1147X.
3. The user should evaluate the use conditions of the rod considering its mechanical and chemical characteristics in order to avoid making efforts that deteriorate the rod or process fluids that may cause its corrosion.
April 2015
Japan
E4 Japan Flameproof (0065 only)
Certificate: TC17226 Markings: Ex d IIC T6;(-20 °C ≤ Ta ≤ +65 °C); Process Temperature: -20 °C to +85 °C
Special Condition for Safe Use (X):
1. The wiring shall be suitable for a temperature over 80 °C.
EAC – Belarus, Kazakhstan, Russia
EM Technical Regulation Customs Union (EAC) Flameproof
Certificate: RU C-US.GB05.B.00289 Markings: 1Ex d IIC T6…T1 Gb X
Special Condition for Safe Use (X):
1. See certificate for special conditions.
IM Technical Regulation Customs Union (EAC) Intrinsic Safety
Certificate: RU C-US.GB05.B.00289 Markings: 0Ex ia IIC T6 Ga X; Ga/Gb Ex ia IIC T6 X; 1Ex ia IIC T6 Gb X
Special Condition for Safe Use (X):
1. See certificate for special conditions.
Combinations
KD Combination of E1, E5, and E6
K1 Combination of E1, I1, N1, and ND
KM Combination of EM and IM
10
Page 11
April 2015
Quick Start Guide
Figure 3. Rosemount 0065 Sensor Assembly Declaration of Conformity
11
Page 12
Quick Start Guide
c
April 2015
12
Page 13
April 2015
Quick Start Guide
13
Page 14
Rosemount World Headquarters
Emerson Process Management
6021 Innovation Blvd Shakopee, MN 55379, USA
+1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 [email protected]
North America Regional Office
Emerson Process Management
8200 Market Blvd. Chanhassen, MN 55317, USA
+1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 [email protected]
Latin America Regional Office
Emerson Process Management
1300 Concord Terrace, Suite 400 Sunrise, Florida, 33323, USA
+1 954 846 5030 +1 954 846 5121 [email protected]
00825-0200-2654
Quick Start Guide
00825-0200-2654, Rev. BC
April 2015
Europe Regional Office
Emerson Process Management Europe GmbH
Neuhofstrasse 19a P.O. Box 1046 CH 6340 Baar Switzerland
+41 (0) 41 768 6111 +41 (0) 41 768 6300 [email protected]
Asia Pacific Regional Office
Emerson Process Management Asia Pacific Pte Ltd
1 Pandan Crescent Singapore 128461
+65 6777 8211 +65 6777 0947
Middle East and Africa Regional Office
Emerson Process Management
Emerson FZE P.O. Box 17033, Jebel Ali Free Zone - South 2 Dubai, United Arab Emirates
+971 4 8118100 +971 4 8865465
Standard Terms and Conditions of Sale can be found at: www.rosemount.com\terms_of_sale. The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount and Rosemount logotype are registered trademarks of Rosemount Inc. All other marks are the property of their respective owners. © 2015 Rosemount Inc. All rights reserved.
Loading...