EMERSON PT5-07M, PT5-18M, PT5-30M, PT5-50M, PT5-07T DATASHEET

...
Pressure Transmitters
D A T A S H E E T
The PT5 series of Pressure Transmitters convert a pressure into a linear electrical 4 .. 20mA output signal suitable for controlling simple compressor and fan switching to the more sophisticated application of superheat modulation of EX series Electrical Control Valves.
With competitive performance to price characteristics and an easy to install pre-fabricated M12 cable assembly, the PT5 transmitters are the designers choice for all refrigeration and air conditioning applications.
PT5
Features
Sensitive pressure cells with strong primary output signals for the precise operation of superheat, compressor or fan controls systems
Fully hermetic
PT5-xxM pressure connector 7/16-20 UNF with Schrader
valve opener
PT5-xxT with 6mm x 50mm long tube for applications requiring a fully hermetic system solution
Output signal 4 to 20 mA
Standard pressure ranges compatible with former
Emerson pressure transmitters - Sealed gauge pressure
Calibrated at pressure and temperature ranges to fulfill demands of today’s refrigeration and HVAC applications
Reduced Full Scale Error characteristics over the complete temperature range
Easy install M12 electrical connection with pre-assembled cable assemblies available in various lengths
Protection class IP 65
Vibration, shock and pulsation resistant
CE-mark under EC EMC-Directive
PT5-xxM
PT5-xxT
PT4-Mxx Cable Assembly
Options (minimum quantity applies)
Other pressure ranges and calibrations upon request
Self-assembly plug without cable available upon request
Selection Chart, Pressure Transmitters
Part No.
Type
Individually
packaged
Multipack
**
(bar)* (°C) (bar)* (bar)* (bar)* PT5-07M 802 350 802 350M -0.8 to 7 PT5-18M 802 351 802 351M 0 to 18 45 50 250 PT5-30M 802 352 802 352M 0 to 30 45 50 250 PT5-50M 802 353 802 353M 0 to 50 PT5-07T 802 370 802 370M -0.8 to 7 PT5-18T 802 371 802 371M 0 to 18 45 50 250 PT5-30T 802 372 802 372M 0 to 30 45 50 250 PT5-50T 802 373 802 373M 0 to 50
*) Sealed gauge pressure **) PT5xxM: 20 pcs, PT5-xxT: 10 pcs
Pressur e range
for signal output
Output
signal
4 to 20
mA
4 to 20
mA
Fluid
temperature
range
-40 to + 100
-40 to + 100
PS:
Max. working
pressure
PT:
Test
pressure
27 30 150
72 80 400 27 30 150
72 80 400
Burst
pressure
Pressure
Connection
7/16” – 20
UNF (with
Schrader
valve opener)
6mm tube x
50mm long
PT5
Pressure Transmitters
D A T A S H E E T
Selection Chart, Plug/Cable Assemblies: assembly fits all models
Part No.
Type
PT4-M15 804 803 804803M PT4-M30 804 804 804804M PT4-M60 804 805 804805M
Note: Longer length of the electrical connection cable beyond 6.0m must be verified by user in term of output signal as well as EMC within installed system.
Individually
packaged
Multipack
20pcs
Length
1.5 m 50
3.0 m 80
6.0 m 140
Weight
(grams/pcs)
Temperature Range
-50 to +80°C static application
-25 to +80°C mobile application
Introduction
The Emerson pressure transmitters PT5 are designed for pressure sensing and to generate a linear electrical output signal. The products are specifically aimed at applications in the HVACR industry: primarily for refrigeration but also for air conditioning systems.
The PT5 series is protected against short circuit, reverse polarity and over voltage to 36volts.
The standard 4 - 20 mA current output enables easy interfacing with most common signal processing equipment.
Various pressure ranges are available to match the operating pressures commonly encountered in HVACR systems. The PT5 meet the requirements of the European EMC directive and are labelled with the CE-mark according to 2004/108/EEC, EN 61326
PT5-07 PT5-18 PT5-30 PT5-50
20 16 12
8
Output Current (mA)
4 0
-5 0 5 10 15 20 25 30 35 40 45 50 Pressure (bar)
Description
At the heart of the transmitter is a thin film pressure sensitive stainless steel diaphragm on which the strain gauges are directly bonded. The direct integration of the strain gauges means no additional errors are introduced between the location where the pressure acts and where it is measured creating a inherently strong design with minimal hysteresis.
The integrated electronic module conditions the output of the pressure cell to produce a temperature compensated signal of 4…20 mA.
The fully welded monolithic construction creates a fully hermetic product which ensures reliable operation and a long life-time expectation even under severe operating conditions. With the high operating and burst pressures, the PT5 can be applied to all requirements of today’s HVAC systems but is particularly suitable for refrigeration applications.
The protective stainless steel diaphragm ensures compatibility with the media frequently encountered in refrigeration systems whilst the Stainless steel housing provides excellent corrosion resistance. The electrical circuit is sealed to the housing which together with the pre-fabricated cable assemblies provide an IP65 solution for the harshest environment.
PT5 transmitters produce a relative output signal after being calibrated at atmospheric pressure and then sealed during production. When using PT5 in heights significantly above sea level the output signal deviation must be taken into account. i.e. at a height of 1000m the signal reads approximately 0.1 bar lower than the actual pressure.
Pressure transmitters PT5 with current output (two wire connection) offer the following advantages:
More suitable for signal transmission over long distance
Higher immunity to electro-magnetic interference
Open circuit detection enables fail-safe operation
PT5
0.02A
Pressure Transmitters
D A T A S H E E T
Cross Reference
PT5 series offers a one for one replacement for Emerson transmitter series PT3 & PT4 series
PT3 series with 2 meter
PT4 series with cable and plug assembly
PT5 series with cable and plug assembly
fixed cable
PT3-07A PT4-07S and PT4-L30 PT4-07M and PT4-M30 PT5-07M /07T and PT4-M30 PT3-18A PT4-18S and PT4-L30 PT4-18M and PT4-M30 PT5-18M /18T and PT4-M30 PT3-30A PT4-30S and PT4-L30 PT4-30M and PT4-M30 PT5-30M /30T and PT4-M30
n/a n/a PT4-50M and PT4-M30 PT5-50M /50T and PT4-M30
Technical data
Supply voltage Nominal
Range (polarity protected) 7 ... 30 Vdc Burst pressure refer to Table on page 1 Permissible noise & ripple
Influence of supply voltage
Operating current
Load resistance
Response time < 5 ms
Mounting position Non position sensitive
Temperatures Operating ambient housing
Medium Transport and storage
Weight approx.
(without plug and cable assembly)
Accuracy performance
Type Total error * Temperature range PT5-07M/T ±1% FS -40 ….+80 °C PT5-18M/T ±1% FS -20…. +60 °C PT5-30M/T ±1% FS
±2% FS
Typically ±2% FS
PT5-50M/T ±1% FS
±2% FS
Typically ±2% FS
*) Total error includes non-linearity, hysteresis, repeatability as well as offset and span drift due to the temperature changes. Note: %FS is related to P
ercentage of Full sensor Scale.
24 Vdc
< 1 V
p-p
< 0,02 %FS/V
Maximum ≤ 24 mA 4 to 20 mA output
RL
Ub - 7.0V_
Refer to operating instructions for more details
-25.....+80 °C
-40...+100 °C
-25.....+80 °C
80 grams
0 …. +40 °C
-20 …. +60 °C
-40 …. +80 °C 0 …. +40 °C
-20 …. +60 °C
-30 …. +80 °C
Sensor lifetime
Electrical connection
all versions Transmitters
PT4-Mxx Cable Assemblies
10.000.000 cycles at full stroke at 25°C
M12 connection to EN61076­2-101 part 2
Pre-fabricated with various cable lengths
Medium compatibility
not suitable for ammonia and
HFC, HCFC, CFC
inflammable refrigerants! Approvals CE marking according to PED CE marking according to EMC
Not allowed (SEP) CE marked according to
2004/108/EEC, EN 61326
(Certificate upon request)
Vibration at 10…2000Hz max. 4g
Protection class IP65 (acc. to EN 60529)
Materials Housing, pressure connector
and diaphragm with medium contact
stainless steel
1.4534 / AISI 316L
PT5
4 ... 20 mA
5
Pressure Transmitters
Mechanical and Electrical connections
D A T A S H E E T
PT4-Mxx
M12
BN
24 Vdc
1
WH
PT5-xxM (top view)
Dimensions (in mm)
PT5-xxM Series overall dimensions PT5-xxT Series overall dimensions
The PT4-Mxx cable assembly can only be fitted onto the PT5 Pressure Transmitters one way.
Locate the corresponding lug shown as (1) opposite.
BN = brown, WH = white (5) = Electronic Controller e.g.
EC2 & EC3 Series
Plug assembly with Removal Dimensions
38 46
EMERSON is not to be held responsible for erroneous literature regarding capacities, dimensions, applications, etc. stated herein. Products, specifications and data in this literature are subject to change without notice. The information given herein is based on technical data and tests which EMERSON believes to be reliable and which are in compliance with technical knowledge of today. It is intended only for use by persons having the appropriate technical knowledge and skills, at their
Emerson Electric GmbH & Co. OHG ALCO CONTROLS Heerstraße 111 71332 Waiblingen Germany
Phone Fax ...49-(0)7151-509-200
www.emersonclimate.eu
12
own discretion and risk. Since conditions of use are outside of EMERSON’s control we can not assume any liability for results obtained or damages occurred due to improper application. Our products are designed and adapted for fixed locations. For mobile applications failures may occur. The suitability for this has to be assured from the plant manufacturer which may include making appropriate tests. This document replaces all earlier versions.
Benelux Denmark & Finland Eastern Europe, Turkey & Iran France, Greece, Maghreb Deutschland, Österreich, Schweiz Italia Middle East & Africa Poland Russia & Cis España & Portugal Sweden & Norway UK & Ireland
Phone:
+31 (0)773 240 234 +32 (0)87 305 565 +32 (0)87 305 061 +33 (0)478 668 570 +49 (0)6109 6059 0 +39 02 961 78 1 +97 148 832 828 +48 (0)22 458 9205 +7 495 981 9811 +34 93 4 123 752 +32 (0)87 305 565 +44 (0)1 189 838 000
Fax:
+31 (0)773 240 235 +49 24 08 929 568 +32 (0)87 305 506 +33 (0)478 668 571 +49 (0)6109 6059 40 +39 02 961 78 888 +97 148 832 848 +48 (0)22 458 9255 +7 495 981 9816 +34 93 4 124 215 +49 24 08 929 568 +44 (0)1 189 838 001
Loading...