Key Features
n High density panels
save rack space
n The patented Emerson
silo protector block
improves attenuation,
cross talk and
insulation resistance
n Connectorized and
non-connectorized
versions are available
n Gold-plated protector
module sockets
provide superior
electrical contact and
eliminate noise
problems
Protect sensitive electronic equipment from
overvoltages in central office, building entrance
and remote terminal applications.
Description
Protection panels protect sensitive electronic equipment from overvoltages in indoor
racks and outdoor remote terminals. These front access protection panels are configured
for industry standard 5-pin protector modules (sold separately). Connectorized and non
connectorized versions are available for installation on 19-in. or 23-in. racks.
Application
Protector panels are used in central office, building entrance and remote terminal applications and can be rack mounted to protect personnel and equipment from abnormal
voltages and currents (ie., lightning strikes, on incoming cable pairs).
Note: Other protection panels, as well as connectorized and non-connectorized custom configura-
tions can be provided. Call Emerson for additional information.
PROT23100NW
1OSPDS-095300 / 1213
Protection Panels
Ordering Information – Connectorized
Catalog
Number
Part
Number
Cable Length
Connector Type
Cable Length
Field Side Equipment Side
Connector Type
Figure
Number
Connectorized Protection Panels for 19" Racks (3.47"H x 19"W x 1.57"D)
100-pr. protection panel with 25-pr. 24AWG cable on both the equipment and field side
PROT100AC3W3MGP F1005793 3-ft. AMP RJ21 Plug 3-ft. 3M 4005-DPM (MS2), Dry 1
PROT100AC3GR F1007688 3-ft. AMP RJ21 Receptacles 3-ft. AMP RJ21 Receptacles 1
100DIG3M40054 F003041 4-ft. 3M 4005-DPM (MS2), Dry 5-ft. 2-in. 3M 4005-DPM (MS2), Dry 1
100DIGNTMA F1001738 14-ft. AMP RJ21 Receptacles 14-ft. 3M 4005-DPM (MS2), Dry 1
PNL100PRPROT F989050 5-ft. 2-in. 710, Dry 4-ft. 710, Gel-Filled 1
100PROCAT5EPROTPNL F1008027* 10-ft. AMP RJ21 Plug 5-ft. 710, Gel-Filled 1
Connectorized Protection Panels for 23" Racks (3.47"H x 23"W x 1.57"D)
100-pr. protection panel with 25-pr. 24AWG cable on the equipment side and 26AWG on the field side
100PRPROTPNLMSPAN F1006640 10-ft. None 10-ft. None 2
*Pairs 49, 50, 99 & 100 are not wired (dead pairs).
Ordering Information – Non-Connectorized
Catalog
Number
Part
Number Description H W D
Figure
Number
Diagrams
Figure 1
Non-Connectorized, Wire-Wrap Terminated Protection Panels
100-pr.
PROT19100NW F1008036
protection
3.47" 19" 3" 1
panel
100-pr.
PROT23100NW F1007915
protection
3.47" 23" 3" 2
Figure 2
panel
200-pr.
PROT19200NW F1008046
protection
6.63" 19" 3" 3
panel
Accessories
Figure 3
Catalog
Number
RACKADAPTKIT F1008503
EmersonNetworkPower.com/EnergySystems (North America)
EmersonNetworkPower.eu/EnergySystems (EMEA)
© Emerson Network Power Energy Systems North America 2013.
Business-Critical Continuity™, Emerson Network Power™, the Emer son Net work Power l ogo, Emer son® and Consi der it Solv ed are ser vice mark s and
tradem arks of Eme rson Elec tric Co. En ergyMas ter
Netw ork Power En ergy Syste ms North A merica. A ny other pro duct, br and, or compa ny names or lo gos are the pr opert y of the resp ective o wner.
2
Part
Number Description
Bracket adapter kit for mounting 19"
protection panel (100-pr. only) onto 23" rack
™
, eSure™, NetPerform™, NetReach™, NetSpan™, NetSu re™ and NetXtend™ are trad emarks of E merson
While ev ery prec aution has b een taken to e nsure accur acy and
completeness herein, Emerson Electric Co. assumes no responsibility,
and disc laims all liab ility, for da mages resul ting from u se of this
information or for any errors or omissions. Specifications subject to
change without notice.
OSPDS-095300 / 1213