PENBERTHY MODEL CTE MIXER / HEATER
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
Before installation, these instructions must be read carefully and understood.
PRODUCT WARRANTY
Emerson warrants its Penberthy products as designed and manufactured to be free of defects in the material and workmanship for a period of one year after the date of installation or eighteen months after the date of manufacture, whichever is earliest. Emerson will, at its option, replace or repair any products which fail during the warranty period due to defective material or workmanship.
Prior to submitting any claim for warranty service, the owner must submit proof of
TABLE OF CONTENTS
Product warranty ................................................ 1
1 About the manual..................................... 2
2 Introduction ............................................. 2
2.1 Features and specifications ........................ 2
2.2 Design ratings at max. and min.
operatingtemperatures .............................. 2
2.3 Application data ........................................... 2
3 Inspection and performance
confirmation ............................................ 2
3.1 Receiving inspection .................................... 2
3.2 User's rating inspection .............................. 2
4 Installation ............................................... 3
4.1 Mounting ....................................................... 3
4.2 Effect of related piping and precautions .... 3
5 Operation ................................................. 4
5.1 Pre-operational check ................................. 4
5.2 Operating ...................................................... 4
6 Maintenance ............................................ 4
6.1 Preventative maintenance ........................... 4
6.2 Troubleshooting ........................................... 4
7 Disassembly - reassembly ...................... 5
8 Disposal at end of useful life ................... 5
9 Telephone assistance .............................. 5
Tables and figures
Table 1 -
Table 2 - Application data................................. 2
Table 3 - Troubleshooting ................................ 4
Figure 1 - Threaded inlet ................................... 3
Figure 2 - Mounting ........................................... 3
Figure 3 - Mounting ............................................ 3
Design ratings
operatingtemperatures ................... 2
at max. and min.
purchase to Emerson and obtain written authorization to return the product. Thereafter, the product shall be returned to Emerson with freight prepaid.
This warranty shall not apply if the product has been disassembled, tampered with, repaired or otherwise altered outside of the Emerson factory, or if it has been subject to misuse, neglect or accident.
The responsibility of Emerson hereunder is limited to repairing or replacing the product at its expense. Emerson shall not be liable for loss, damage or expenses directly or indirectly to the installation or use of its products, or from any other cause or for consequential damages. It is expressly understood that Emerson is not responsible for damage or injury caused to other products, buildings, personnel or property, by reason of the installation or use of its products.
This is Emerson's sole warranty and in lieu of all other warranties, expressed or implied which are hereby excluded, including in particular all warranties of merchantability or fitness for a particular purpose.
This document and the warranty contained herein may not be modified and no other warranty, expressed or implied, shall be made by or on behalf of Emerson unless made in writing and signed by the company's general manager or director of engineering.
related
Emerson.com/FinalControl
© 2018 Emerson. All Rights Reserved. VCIOM-04060-EN 19/04
Page 2
PENBERTHY MODEL CTE MIXER / HEATER
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
1 ABOUT THE MANUAL
This manual has been prepared as an aid and guide for personnel involved in installation or maintenance. All instructions must be read and understood thoroughly before attempting any installation, operation or maintenance.
IMPORTANT
Emerson does not have any control over the manner in which its CTE is handled, installed or used. Emerson cannot and will not guarantee that a CTE is suitable for or compatible with the user's specific application.
WARNING
Safety glasses and protective clothing should be worn installing a CTE mixer/heater. Failure to follow any instruction may cause a malfunction of the unit in which high pressure liquid or steam may discharge from the unit inadvertently, resulting in severe personal injury and property damage.
2 INTRODUCTION
2.1 Features and specifications
Penberthy CTEs (circulating tank eductors) are designed for in-tank mixing of liquids as the motive fluid and for in-tank heating of liquids using steam as the heating and motive fluid. Mixing is accomplished first within the CTE as the motive liquid entrains the tank contents into the suction openings and mixes with the unit thoroughly before being discharged. The discharge flow, or plume, provides further mixing and agitation within the tank. The motive liquid can be drawn from the tank or it can be a second liquid drawn from another source. Heating is accomplished by direct condensation of steam in the liquid. The motive steam also includes the liquid to flow into the suction openings and discharge from the CTE. The discharge flow or plume provides further mixing and circulation to promote even temperature distribution.
2.2 Design ratings at maximum and minimum operating temperatures
To determine the maximum allowable working pressure for a specific temperature within the design limits stated in Table 1, the user should refer to relevant data sheets or, when provided, the specifically stated design limits on a product proposal.
2.3 Application data
CTE sizes above 3 inches are metal fabrications to be used only for mixing, not for heating. Unless otherwise specified on a product proposal, metal fabrications are not designed for steam heating in tank.
1. Mixing
Minimum inlet pressure - 10 psig (70 kPaG) Maximum inlet pressure - 160 psig (1100 kPaG) Most efficient operation takes place when inlet pressure is within the range of 20 to 70psig (140 to 480 kPaG). Three gallons of tank contents can be mixed for every gallon of operating fluid. For inlet pressures outside this range, 2.6 gallons of tank contents can be mixed for every gallon of operating fluid.
2. Heating (see Table 2)
Operation at steam pressures below those listed for each maximum tank liquid temperature or heating beyond 160°F (71°C) may cause objectionable noise, water hammer, and vibration.
Note: For specific application data within the ranges stated, the user should consult the product proposal for the specific model and size CTE, or should request the supply of the applicable technical data sheet.
WARNING
Under no circumstances should these design ratings or application data be exceeded. Exceeding design ratings or application data can cause the CTE to fail structurally at higher pressures and temperatures causing severe personal injury and property damage.
3 INSPECTION AND PERFORMANCE CONFIRMATION
3.1 Receiving inspection
Upon receipt of the CTE, check all components carefully for damage incurred in shipping. If damage is evident or suspected, do not attempt installation. Notify the carrier immediately and request a damage inspection.
3.2 User's rating inspection
The user should confirm that:
1. The CTE size and model designation (cast on side of body) conforms to the description on the user's purchase order.
2. The operating conditions described in the purchase order agree with the actual operating conditions at the installation site.
3. The actual operating conditions at the installation site are within the application data shown on the relevant technical data sheet or product proposal referred to above.
4. The materials of construction of the CTE are compatible with both the contained fluid and the surrounding atmosphere in the specific application.
IMPORTANT
If the size, model or performance data of the CTE as received does not conform with any of the criteria above, do not proceed with installation. Contact an authorized Penberthy distributor for assistance.
TABLE 1 - DESIGN RATINGS AT MAX. AND MIN. OPERATING TEMPERATURES
Size Material Maximum allowable working pressure
⅜" thru 3" Iron, bronze and SS 160 psig [1100 kPaG] at -20°F [-29°C] to +370°F [188°C] 4" - 6" and 8" Carbon steel 160 psig [1100 kPaG] at -20°F [-29°C] to +200°F [ 93°C]
⅜" thru 3" PVC
⅜" and ¾" Kynar
⅜ and ¾" Polypropylene
Note: Kynar® is a registered trademark of Arkema polyvinylidene fluoride (PVDF) resin.
®
100 psig [690 kPaG] at +70°F [ 21°C] 20 psig [140 kPaG] at +140°F [ 60°C] 100 psig [690 kPaG] at +70°F [ 21°C] 20 psig [140 kPaG] at +275°F [135°C] 100 psig [690 kPaG] at +70°F [ 21°C] 25 psig [170 kPaG] at +170°F [ 77°C]
TABLE 2 - APPLICATION (HEATING)
Min. steam pressure Max. tank liquid temp.
psig kPaG °F °C
10 70 70 21 20 140 100 38 25 170 120 49 34 230 140 60 50 340 160 71
2
Page 3
PENBERTHY MODEL CTE MIXER / HEATER
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
4 INSTALLATION
Installation should only be undertaken by qualified, experienced personnel who are familiar with this equipment and have read and understand all the instructions in this manual. The user should refer to the relevant technical data sheet or product proposal to obtain dimensional information for the specific size and model of CTE. Check the cut-away view (Figure 1) for the location of the threaded inlet.
4.1 Mounting
A CTE can be mounted in any position. The supply line and manifold piping to multiple CTEs must be sized to supply uniform pressure to each CTE. It is important that the CTE be positioned within the tank so as to insure the free flow of liquid to be mixed or heated into and out of the unit(s). The greatest agitation occurs within the discharge plume; therefore, the discharge end should be aimed towards the most remote part of the tank. On the other hand, the intake end of the unit must be far enough from the tank corner or wall to allow the free flow of liquid into the suction openings. Tank shape and size influence the placement and number of CTEs required to maintain even agitation or temperature distribution. With a spherical tank, a single CTE mounted as shown in Figure 2 makes the best use of the mixing and heating characteristics of the CTE. With no corners to impede liquid flow, the liquid circulates evenly and undisturbed. In a cylindrical, square or rectangular tank, the angular intersection of surfaces can interrupt liquid flow patterns and cause liquid stagnation in these areas. A single CTE mounted as shown in Figure 3 will minimize this. Whenever the ratio of length to diameter of the tank is greater than 2:1 (such as tank trucks or railroad cars), it is recommended that multiple CTEs be used.
4.2 Effect of related piping and precautions
1. For mixing
a. Operating liquid supply line pressure loss
must be taken into account when applying CTEs.
b. Supply line must be clean and should be
provided with a strainer to prevent foreign materials from clogging the mixer.
c. CTEs must be fully submerged to prevent
liquid from splashing and drawing atmospheric air, and to promote maximum mixing.
d. Clearance should be provided for removal of
the CTE.
e. Provisions should be made for a pressure
gauge connection at or near the CTE inlet. It may become necessary to install a pressure gauge if operating difficulties are encountered.
FIGURE 1
Inlet
FIGURE 2
Spherical
FIGURE 3
f. Inlet piping must be secured to the tank wall
near the CTE to keep strain off piping when in operation.
g. Supply line and manifold piping must be
sized to supply adequate pressure equally to each CTE when multiple CTEs are used.
2. For heating
a. Steam must not have more than 20°F (-7°C)
of superheat or performance will differ from that published in the relevant technical data sheet or product proposal referred to previously.
b. Steam line pressure loss must be taken into
account when applying CTEs.
c. The steam line must be clean and should be
provided with a strainer to prevent foreign materials from clogging heater.
d. The steam line must be insulated and as
short as possible to prevent condensation and friction losses.
e. CTEs must be fully submerged to prevent
liquid from splashing and to promote condensation.
f. Clearance should be provided for removal of
the CTE.
Body
Discharge
g. Provisions should be made for a pressure
gauge connection at or near the CTE inlet. It may become necessary to install a pressure gauge if operating difficulties are encountered.
h. Steam piping must be secured to the tank
wall near the CTE to keep strain off piping when in operation.
i. The steam supply valve must be a quick
opening type installed as close to the CTE as practical.
3
Page 4
PENBERTHY MODEL CTE MIXER / HEATER
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
5 OPERATION
5.1 Pre-operational check
1. Ensure that all installation procedures have been completed.
2. Fill the tank with sufficient liquid for full submergence of the CTE.
5.2 Operating
1. For mixing
a. Turn operating fluid flow on (depending
upon the application, this may be liquid drawn from the tank, or it can be a second liquid drawn from another source).
2. For heating
a. Turn the steam flow fully on and maintain
throughout the heating process.
b. After the desired temperature is reached,
the steam pressure should be turned off.
3. Do not throttle the steam supply valve. Throttling of steam flow to conditions outside the recommended operating levels will cause the CTE to hammer with resulting noise and vibration.
IMPORTANT
Excessive vibration can become hazardous due to loosening of pipe joints and release of steam.
Temperature of liquid can be controlled thermostatically only if the steam supply is controlled with a snap acting on-off valve.
WARNING
Do not attempt to heat liquid beyond the maximum stated temperature of 160°F (71°C). Where the user has an open tank installation, heating beyond the maximum does not allow the steam time enough to condense fully by the time it reaches the surface of the liquid, thus splashing can result causing severe personal injury or property damage.
6 MAINTENANCE
WARNING
Maintenance should only be undertaken by qualified, experienced personnel who are familiar with this equipment and have read and understood thoroughly all the instructions in this manual. DO NOT proceed with any maintenance unless the CTE has been relieved of all pressure or vacuum, has been allowed to reach ambient temperature and has been drained or purged of all fluids. Failure to follow these instructions may cause a sudden release of liquid or steam resulting in severe personal injury or property damage.
The user must determine an appropriate maintenance schedule necessary for his or her own specific application upon evaluation of their operating experience. Realistic maintenance schedules can only be determined with full knowledge of the services and application situation involved.
6.2 Troubleshooting (see Table 3)
Example: A CTE is employed in raising the
water temperature in a given tank from ambient to 160°F (71°C) and it is sized to accomplish the job using 50 psig (340 kPaG) steam over a period of 30 minutes. Once the tank temperature reaches 160°F (71°C), obviously it will take much less quantity of steam to maintain the tank at 160°F (71°C) than it did to get there. If the steam flow was throttled to maintain 160°F (71°C) in the tank, the steam pressure would drop necessarily below 50psig (340 kPaG) at the CTE and then noise and vibration can be expected. 50 psig
6.1 Preventative maintenance
The user must create maintenance schedules, safety manuals and inspection details for each specific installation of a CTE mixer/heater. On all installations, the following items should be evaluated regularly by the user for purposes of maintenance:
1. CTE(s) for corrosion or debris buildup.
2. Piping and fittings for corrosion or debris build up.
3. All connections for tightness.
4. Units for wear.
5. Units for full submergence.
(340 kPaG) is the recommended minimum steam pressure for quiet operation when the tank temperature is 160°F (71°C).
TABLE 3 - TROUBLESHOOTING
Problem Cause Solution
No mixing or heating taking place
Partial mixing or heating 1. Debris blockage 1. Remove debris
Noise, water hammer, vibration when heating
1. Inadequately sized CTE 1. Obtain properly sized CTE
2. Debris blockage of inlet, suction or discharge 2. Remove debris
3. Loss of operating fluid due to loose connections 3. Tighten connections
4. Operating fluid pressure too low 4. Increase pressure
2. Operating fluid pressure too low 2. Increase pressure
3. Increased product demand 3. Reduce product flow to heating capability of unit
1. Operating pressure too low or liquid temperature too high 1. Increase pressure or decrease temperature
2. Throttling of steam flow 2. Thermostatically controlled heating cycles with snap acting on-off valve
3. Set point is too high (such as 200°F [93°C]) 3. Decrease to recommended operating level
4
Page 5
PENBERTHY MODEL CTE MIXER / HEATER
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
7 DISASSEMBLY - REASSEMBLY
WARNING
Do not proceed with removal of the CTE from connecting piping unless the CTE has been relieved of all pressure or vacuum, has been allowed to reach ambient temperature and has been drained or purged of all fluids. Failure to follow these instructions may cause a sudden release of liquid or steam resulting in severe personal injury or property damage.
8 DISPOSAL AT END OF USEFUL LIFE
Penberthy CTEs are used in a variety of fluid applications. By following the appropriate federal and industry regulations, the user must determine the extent of preparation and treatment the CTE must incur before its disposal. A Material Safety Data Sheet (MSDS) may be required before disposal services accept certain components. Metal, glass and polymers should be recycled whenever possible. Refer to order and relevant data sheet for materials of construction.
9 TELEPHONE ASSISTANCE
If attempts to solve your problem fail, you may request to return your CTE to the factory for intensive testing. You must obtain a Return Authorization (R.A.) number from Emerson before returning anything. Failure to do so will result in the unit being returned to you without being tested, freight collect. To obtain an R.A. number, the following information (in addition to that above) is needed:
- Reason for return
- Person to contact at your company
- 'Ship-to' address
There is a minimum charge for evaluation of non-warranty units. You will be contacted before any repairs are initiated should the cost exceed the minimum charge. If you return a unit under warranty, but it is not defective, the minimum charge will apply.
If you are having difficulty with your CTE, contact your local Penberthy distributor. So that we may assist you more effectively, please have as much of the following information available as possible when you call:
- Model number
- Name of the company from whom you purchased the CTE
- Invoice number and date
- Process conditions (pressure, flow rates, tank shape, etc.)
- A brief description of the problem
- Troubleshooting procedures that failed
Neither Emerson, Emerson Automation Solutions, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user.
Penberthy is a mark owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Emerson Automation Solutions, Emerson andthe Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice.