Emerson NetSure RDB, Liebert APM 15-90kW, Liebert NX 40-200kVA, Liebert GXT3 500-3000VA, Liebert PSA UPS 500-1500VA Brochure

...
Liebert® Power Solutions
Data Center Protection As Dynamic As Your Business
A Comprehensive Power Solution—Only From Emerson
The Widest Range Of Technologies
UPS Systems
Emerson Network Power offers Liebert brand UPS in all three major uninterruptible power supply (UPS) system configurations:
Line-Interactive UPS—Provides power conditioning with a 2-6 ms break in power when transferring to battery back-up.
On-Line (Double Conversion) UPS—Delivers continuous, high-quality AC power to equipment with no break when transferring to battery. Protects equipment from virtually all power disturbances due to blackouts, brownouts, sags, surges or noise interference.
Emerson Network Power offers UPS systems in the industry’s
widest range of sizes including desktop and workstation UPS,
rack-mount, network and large facility UPS for full facility power.
Critical Electrical Distribution
Emerson Network Power offers a range of power distribution systems designed to efficiently deliver conditioned power to your critical equipment. These products include high-reliability distribution systems, starting with rack PDU systems, specially designed for computer and communications applications, as well as transfer switches offering ultra-fast transfer between two independent AC power sources to provide virtually uninterrupted power to sensitive electronic equipment.
Power Quality Protection
For applications requiring protection from electrical line disturbances without the need for back-up capability, Emerson manufactures a full line of power conditioning equipment. It includes a wide variety of transient voltage surge suppression (TVSS) solutions ranging from high-quality surge suppressors for use with PCs, workstations and other peripherals to facility-wide systems with sophisticated active tracking capability.
DC Power Systems For Communications Applications
From major switching centers to remote shelters, Emerson DC power systems offer performance and features to match virtually every telecommunications equipment application. The line includes a variety of system capacities ranging from small systems at less than 3 kW up to large systems rated at over 60 kW. The product offering also includes distribution bays, enclosures and network management products such as controllers, monitors and supervisory software to control and maintain energy equipment in a telecommunications network.
Power System Monitoring
Liebert brand power communications software and hardware provides multiple levels of monitoring and control. Capabilities range from automated shutdown software to facility-wide centralized systems that provide a full range of monitoring, control and analysis.
2
There Is A Liebert Power Solution To Meet Every Need
CONTENTS
1 Racks, Integrated Cabinets, Modular Power Distribution
8 Rack Enclosure System
9 Liebert® MCR Mini Computer Room Enclosure
10-11 Smart Solutions
12-13 Liebert MB Modular Busway
2
Rack PDU
14 MPX Adaptive Rack PDU
15 MPH2 Managed Rack PDU
16 Rack PDU Monitoring Solutions
17 DI-STRIP®, Basic and High Power Rack PDU
3 Desktop/Workstations UPS
18 Liebert PSP Stand-by UPS, 350-650VA
19 Liebert PSA Line-Interactive UPS, 500-1500VA
4 Rackmount Uninterruptible Power Supply (UPS)
20-21 Liebert PSI-XR and Liebert PSI Line-Interactive UPS, 750-3000VA
22 Liebert GXT3 On-Line UPS, 500-3000VA
23 Liebert GXT3 On-line UPS: 5-10 kVA
5 Network Uninterruptible Power Supply (UPS)
24 Liebert APS™ On-Line UPS: 5-20 kVA
25 Liebert NX On-line UPS: 10-30 kVA
26-27 Liebert APM On-line UPS: 15-90 kVA
Computer Rooms
Data Centers
Network Closets
Production
Labs & Testing
Telecom / CATV
Emergency Shelters
Desktops / Peripherals
Point-Of-Sale
6 Large Facility Uninterruptible Power Supply (UPS)
28-29 Liebert NX On-line UPS: 40-200 kVA
30-31 Liebert eXL™ On-Line UPS:625-1200kVA
32-33 Liebert NXL On-Line UPS: 250-1100 kVA
34 Liebert NXL System Control Cabinet
ENERGY STAR
7
35 ENERGY STAR Qualified UPS Products
®
8 Power Distribution Systems For Critical Protection Applications
36-37 Liebert RX Remote Power Distribution cabinet
38 Liebert FDC Remote Distribution Cabinet
39 Liebert FPC Power Conditioning & Distribution Cabinet
40 Liebert PPC Power Conditioning and Distribution Cabinet
41 Liebert STS2 Static Transfer Switch2 (STS2)
42 Liebert STS2/PDU Static Transfer Switch/Power Distribution Unit
43 Liebert Power Systems Test Center
9 Surge Protection And Power Conditioning Systems
High Exposure Systems, Low & Medium Exposure Systems,
44-45
Home & Office Protection, and Data/Signal Line Protection
10 DC Power Systems For Telecommunications Applications
46-47 Small Power, Medium Power, Large Power, Inverter Systems, Batteries & Accessories
11 Monitoring And Control
48-49 Liebert IntelliSlot, Liebert Nform™ & Liebert SiteScan Web
50-51 Liebert Services
Trouble Is Coming Down The Power Line And You Must Be Prepared
Every operation in your business depends upon the instant, around-the-clock availability of computers, servers and other electronic systems. If they aren’t working, neither is your company.
Unfortunately, every piece of this equipment your company possesses is subject to the whims of the electricity that powers it.
The first step in taking control of this situation is to understand the threats to your system reliability—and exactly what you can do about them.
You Face Many Challenges In The Pursuit Of Productivity
Is There Really A Problem?
“My computer can ride right through a short blip
in the power—why do I need anything else?”
Different Needs Require Different Power Protection Configurations
“Should I have a small UPS for each workstation or have everything on one large system. Which is best for my facility?”
A Lot Can Happen Between Your UPS And The Equipment It Is Protecting
“We have dozens of pieces of networking equipment.
How can I make sure that each one is getting exactly
the power it needs?”
Every Wire Carries The Potential For Trouble
“An electrical surge came in through an outside phone line and knocked out our entire communications system. Is this going to happen again?”
A Single Source Of Power Simply May Not Be Enough
“Adding a second power feed would certainly enhance
our availability picture—but who can we talk to about
getting it done right?”
You Need To Optimize Life Cyle Efficiency
“Budgets are tight, so I have to consider equipment costs
at all lifecycle phases — first cost, operation, and service.
How do I maximize efficiency and ensure reliability?”
4
But There Are Real Solutions
You Need Protection From All Power Problems
An outage is just the problem you can see. There are many other more frequent power fluctuations—surges, spikes, sags—
that you don’t see. These are the conditions that cause the “unexplained” lock-ups and other potentially damaging results.
Protecting critical network and computing systems requires the expertise of someone who understands all the risks you
face from poor power quality.
Centralized Vs. Distributed UPS Protection
Emerson Network Power has the breadth of products that allows you to implement either a centralized or a one-on-one
distributed power protection strategy depending on your requirements. Whatever configuration you choose, you can
count on Liebert to make it the best it can be. Benefits, such as increased system security, more efficient maintenance and
improved reliability, may make a centralized strategy a better choice for larger operations.
Proper Power Depends On Proper Distribution
In network applications, there may be hundreds of different loads with various voltage requirements, a mix of AC and DC
power, plus any number of other electrical specifications. This calls for a distribution system that is designed to maintain the
highest levels of reliability and quality between the source of conditioned power and the protected equipment.
Power Conditioning And Surge Protection Throughout The Facility
Power conditioning and surge suppression systems are key to maintaining power quality in critical facilities. Raw utility
power is often far too “dirty” for sensitive systems, resulting in lost or garbled data, unexpected software glitches
or shutdowns, even hardware damage. The IEEE recommended practice is to install transient voltage surge suppression
(TVSS) protection on every electrical conductor that penetrates a facility shell, including power lines, telephone and
other communications links.
Maximum Protection Demands Dual Power Sources
If your needs require the highest level of system availability, Emerson has the knowledge and products to implement a
dual-power strategy throughout your enterprise. UPS, transfer switching, power distribution and other equipment
are all brought together to create the ultimate in reliability.
Maximum Efficiency Technologies Optimize TCO, PUE
For businesses with a focus on operational and energy efficiency, Emerson Network Power offers reliable technologies with
features that provide capacity on demand, efficiency in all modes of operation, and design features that reduce installation
costs and footprint, and provide easy maintenance and service.
5
Biotechnology
Industry
Where Do You Need Mission-Critical Power Protection Technology?
Health Care
Retail
Distribution
Government
Industrial
Computer
Systems
We have efficient, high
availability power solutions for
any of the applications that are
part of your mission-critical
business operations.
Large Data CentersHigh
availability data and network
applications are the heart of your
enterprise with blade servers and
high-density racks that demand
increased power protection.
Small To Mid-Size Data Centers
Smaller sized network and
computer facilities, but equally
essential to your operations.
IDF Rooms and Network Closets
Housing routers, switches,
modems, cabling devices and
numerous other
communications components.
Network Operations Centers
As networks expand and grow
more complex, you need reliable
and timely access to
mission-critical infrastructure
monitoring information long before
problems arise.
Production—Smart factories
backed by a complex electronic
network, from computer-controlled
machinery and processes to
electronic sensors, business systems
and utility equipment.
Laboratories and Testing—Sensitive
computers and equipment used for
diagnosing patients, analyzing data,
performing critical tests, and
operating electronic tools and
lab instruments.
Telecom/CATV—Anything from
indoor and outdoor spaces hosting
cable, DSL and fiber optics to remote
cell sites and enclosures.
Emergency Shelters—Emergency
operations centers, 911 response
emergency dispatch, police and fire
facilities, medical facilities, public
works operations and more.
Liebert has identified ten distinct zones or areas of application, found
within many business operations, which have a requirement for
mission-critical power technology. While these zones have similarities
in the importance of their essential functions, they also have
different needs for infrastructure protection—all of which can be met
by Liebert solutions.
Desktop/Peripherals—Home and
small office computers, modems,
network components and other
electronic equipment that is vital
to business operations.
Point-of-Sale—Today’s cash
registers and store-level computer
networks not only handle sales
transactions, they also collect
and transmit vital customer and
inventory data required to make
informed supply chain decisions.
6
+
A C I N PU T B A TT E R Y U P S O N B
Y P A S S
U P S t a ti o n G X T
+
A C I N P U T B A T T E R Y U P S O N B
Y P A S S
U P S t a t i o n G X T
+
A C I N P U T B A T T E R Y U P S O N B
Y P A S S
U P S t a t i o n G X T
+
A C I N P U T B A T T E R Y U P S O N B
Y P A S S
U P S t a t io n G X T
+
A C I N P U T B A T T E R Y U P S O N B Y
P A S S
U P S ta t i o n G X T
+
A C I N P U T B A T T E R Y U P S O N B Y
P A S S
U P S t a t i o n G X T
+
A C I N P U T B A T T E R Y U P S O N B Y
P A S S
U P S ta t i o n G X T
+
A C I N P U T
B A T T E R Y
U P S O N
B
Y P A S S
U P S t a t i o n G X T
+
A C I N P U T
B A T T E R Y
U P S O N B
Y P A S S
U P S t a t i o n G X T
+
A C I N P U T
B A T T E R Y
U P S O N B
Y P A S S
U P S ta tio n G X T
+
A C I N P U T
B A T T E R Y
U P S O N B
Y P A S S
U P S t at io n G X T
+
AC I
NPU T B A TTE R Y U PS O N B YP A S S
U P S t a ti o n G X T
+
A C I
NP UT BA TT E R Y UP S ON B YP AS S
U P S ta t io n G X T
Telecom Wireline/Wireless Sites
+
A C I N P U T B A T T E R Y U P S O N
B Y P A S S
U P S t a t i o n G X T
+
A C IN P U T B A T T E R Y U P S O N
B Y PA S S
U P S t a t i o n G X T
Liebert can provide a reliable flow of both AC and DC power for telephone switching systems and other communications equipment.
Emergency Shelters
High-reliability Liebert UPS systems and DC power equipment are critical to maintaining operations in telecommunications shelters and other unmanned structures.
IDF Rooms and Network Closets
These densely-packed equipment bays, housing servers or other essential communications devices require UPS back-up plus distribution to get uninterrupted, conditioned power to each and every component in the rack.
Network Operations Centers
With many mission-critical computing systems located right in the office space, there is a need for UPS protection that can be placed nearby. Liebert offers a number of power systems that are especially designed for use in business and office environments.
Data Center
Liebert offers the full range of UPS, distribution systems and other power protection equipment to meet the needs of the largest data centers and networking facilities.
Small to mid-size Data Center
Liebert offers the full range of UPS, distribution systems and other power protection equipment that can adapt to data center growth requirements.
Production
Liebert UPS, surge protection and power distribution are all key to maintaining the proper operation of process control and other manufacturing systems that utilize microprocessor and computer control.
Mechanical Rooms
Liebert power protection and conditioning systems can greatly improve the operation of electrical switchgear and motor control centers vital to numerous functions throughout an industrial facility.
7
Racks And Cabinets
A Rack System Designed to Meet The Challenges Your Data Center Faces Today
Your mission-critical networks are carrying an ever-increasing amount of voice, data and video. Looming on the horizon is a critical mass of VoIP, high speed access, wireless applications and increasing demand for blade server deployment.
The DCF optimized rack system from Emerson Network Power integrates your computing hardware, power management technologies and peripherals in your data center. It gives superior
design and exibility, allowing
optimal data center equipment performance andeasy installation.
Welded Steel Construction
Integrated 19” rail alignment.
Insures 19” rails are positioned correctly without measuring.
Tool-less Cable Management
requires just inserting and twisting the tool-less accessories on 19” vertical mounting rail.
Roof Top Ready for Cabling
Removable opening for cable entry — ready for front/rear/side cabling. Can accomodate over 2500 Cat 5e cables.
75% Perforation On Doors
Optimal door perforation allows greater airflow through the cabinet, reducing heat buildup.
DCF Rack is UL certified 2416
Ready-To-Deploy Rack And
Enclosure Solutions.
DCF racks provide the convenience of robust 19” racks with high-end features and standardized options to provide fast customization for individual site needs. The racks are designed for optimized air flow and maximized useful mounting space.
8
Split, Locking Side Panels
For quick and easy installation and maintenance. Locks provide security.
Low Profile casters
Low profile casters allow 42U racks access thru a standard doorway
Liebert® MCR
Integrated Cooling Enclosure, 1.6kW and 3.2kW
Liebert IP Telephony Availability System
Secure Door
lockable door provides an extra measure of security by limiting access to critical equipment
BCM
(Back-up Cooling Module)
Sealed Door
specially designed rubber gasket provides NEMA12 sealing protection
Liebert GXT3
on-line UPS
ECM
(Environmental Control Module)
Protecting The Edge Of The Network
Liebert has brought together several of our product solutions to create the IP Telephony Availability System. Especially designed to protect switches, routers and other critical components, this solution is ideal for use in remote locations such as branch offices, retail stores and other edge of the network applications. Housed in a Liebert Foundation or freestanding enclosure.
The Liebert IP Telephony Availability System, version 1.0, has met the Cisco Technology Developer Partner Program test criteria for interoperability with Cisco CallManager Express
3.1, Cisco Unity Express, release 1.1.2, Cisco Unity 4.0 (3), and Unity Bridge 3.0 (2).
wall mount enclosure
True On-Line Power Protection
The Liebert GXT3, a true double conversion UPS, delivers the high level power quality required to fully protect critical network switching components from all power problems. Available in sizes from 500 up to 3000 VA.
Continuous Power Availability
Racks, Integrated Cabinets
Bundled UPS
systems available
Dual-Split Rear Door available
Wall Mount Systems 12 U
Hinge Body “swing out” and 12” depth Low Profile available.
EX Cable Management Channel
This versatile option helps to enhance cabling organization and internal airflow.
Liebert MCR Enclosure
For smaller spaces requiring the complete power and cooling protection.
Internal Power Distribution
A wide range of installed power strips is available to better accommodate power distribution needs within the enclosure.
In most cases, your critical routers and other network components cannot be without power even for scheduled UPS maintenance. To meet this need, the Liebert 2U Power Output Distribution (POD) system ensures continuous uptime by providing maintenance bypass capability as well as power output distribution.
Power System Monitoring, Communications & Remote Control
The Liebert Webcard, housed within the UPS, will deliver SNMP and web-management communications capabilities to your power system, including the ability to remotely reboot the switch by cycling the UPS power off and on.
9
Smart Solutions Deliver Efficiency, Capacity, Availability, Control
To help you achieve efficiency in all aspects of your data center, Emerson Network Power has developed the Smart Solutions intelligent, integrated infrastructure for data centers. The family uses a global design approach that can be localized for specific geographies.
Smart Solutions let you cost-effectively achieve and manage your objectives for efficiency, capacity and availability. These offerings provide fast and easy implementation, through interoperable systems: precision cooling, UPS, power distribution/conditioning, management software and racks.
No other solution offers the industry’s leading power, precision cooling and data center infrastructure management systems for such a wide array of applications and environments.
Smart Solutions are fast and easy to implement, and are supported by local data center design experts and service professionals. Smart Solutions are typically more affordable than conventional data center designs – and they are more energy efficient.
Each Smart Solution offering integrates industry best practices in data center design and operations including:
Hot air and cold air separation
Cold air containment
High availability and high efficiency UPS
High-efficiency precision cooling
Space-savings, small-footprint
Modularity for flexibility and easier expansion
Integrated monitoring and control to optimize efficiency in
planning and management
Unique local service for design audits, configuration support,
installation support, maintenance and repair
Emerson Network Power brings together the industry’s finest power, precision cooling, monitoring and management brands and businesses, including Liebert, Knurr, ASCO, Avocent, Chloride, Energy Systems and Surge Protection solutions. The Smart Solutions offerings deliver Efficiency Without Compromise™ within the data center.
10
Smart Solutions give you the efficiency, economy, interoperability and control to implement an infrastructure
strategy that outperforms any you’ve ever seen.
Efficient
Up to 28% in energy savings Increase rack density up to 60%
Economical
Reduce implementation costs compared to conventional data center approaches
Interoperable
Maximize use of existing infrastructure Depending on the solution, you can have a complete infrastructure in just weeks
Controllable
Easily enforce add / change policies Speed IT administration request response times by up to 30%
SmartRow™ Intelligent, integrated infrastructure in a self-contained line-up
Capacity: 20kW Racks: 3-6 Typ e: Self-contained Floor: Primarily non-raised Key Applications: Small
data centers; remote sites; disaster recovery
The SmartRow solution has a room neutral design that lets you avoid many of the significant costs that come with a conventional data center buildout.
Favorable implementation costs compared to using a
conventional data center approach, due to savings from integrated fire suppression and ability to work in an existing non-raised floor environment without dedicated room cooling.
Has demonstrated up to 10% CAPEX savings over conventional
designs and 27% OPEX savings, perform less maintenance and reduce the costs of adding new equipment.
Order and install in just weeks.
Smart Solutions
SmartMod™ Intelligent, integrated infrastructure in a rapid deployment enclosure.
Capacity: 30-400kW Racks: 6-28 Typ e: Self-contained Floor: N/A Key Applications:
Supplemental data center capacity; remote data centers; disaster recover y
SmartAisle™ Intelligent, integrated infrastructure using row-based building blocks.
Capacity: Most cost effective up to 400kW Racks: Most cost-effective up to 40 Typ e: Open or aisle containment available
Floor: Raised, non-raised Key Applications: Small
and medium data centers; high-density zones in all data centers; new or retrofit
The SmartMod™ enclosure lets you save on upfront design and implementation by delivering fully integrated power, precision cooling, integrated fire suppression and management systems in a modular, standalone design.
Rapidly deploy a comprehensive data center
infrastructure solution.
Implement a stand-alone solution that won’t burden the
existing infrastructure.
Save on design, equipment purchase and installation.
Order and install in just months.
Reduce energy consumption by up to 28% compared to a
data center with conventional design.
The SmartAisle™ offering can increase your efficiency through row-based power and precision cooling systems.
Save up to 27% in energy costs
Keep infrastructure on pace with equipment changes,
with systems that operate together and can be quickly reconfigured
Increase capacity without replacing old infrastructure.
11
Liebert® MB Modular Busway: Flexible, Economical Power Delivery From PDU To Rack
Emerson Network Power brings you the most flexible, robust power distribution system on the market today: Liebert MB Modular Busway.
Modeled on the Siemens XJ-L busway, Liebert MB provides flexible modular power distribution in high tech environments. Power cables are replaced. Installation is simplified. Each rack has a clearly identified breaker. Air flows freely. Installation and ongoing costs are reduced. And the solution is organized and easy to maintain.
Liebert MB is a convenient, economical way to provide power from a room power distribution unit to the IT rack equipment. This compact, modular system is an organized alternative to custom cabling, and is a perfect solution for dynamic data centers that require frequent updates and changes with little to no power disruptions.
System Compatibility
Liebert MB is compatible with the Knurr DCM rack and the entire family of Liebert power products — rack and room PDUs, UPS systems and surge protective devices — providing power distribution and protection.
Ideally Suited For:
Large or medium data centers.
Data centers with variable and dynamic loads.
High power density applications.
Single or dual bus configurations.
Liebert MB Features:
Comprehensive offering of standard fittings.
Reconfigure to meet growing and changing IT demands.
Lightweight and flexible for easy installation, but rugged
enough for durability.
15-30% lower cost than typical cabling materials and
labor/installation costs.
UL 857 and CSA 22.2 agency ratings for safety.
100A, 225A and 400A availability.
Hot swappable, user replaceable bus plugs provide both
flexibility and maximum safety.
Bus plug capacities from 30A to 100A.
Pre-assembled bus plugs with whips or receptacles.
Multiple bus plug port spacing available.
Rack-mount, ceiling suspended or underfloor mounting options.
Optional metering at bus plugs or tap box.
Liebert Power Monitoring Capabilities
The operation of Liebert MB can be monitored using:
Liebert SiteScan
For more information, see pages 52 and 53.
®
Web Centralized Monitoring System.
12
Modular Power Distribution
®
Liebert
Battery Cabinet
NX™
Liebert NX UPS
Tap Box
Liebert
NX BDC
Liebert MB™
Modular Busway
Bus Plug
MPX™ Rack PDURack
13
MPX - Adaptive Rack PDU: Respond To Change While Watching Your Bottom Line
Confidently take on the uncertain future of connected power requirements with MPX, the most responsive and adaptive rack PDU available. With MPX rack PDU technology, you can respond to rack equipment changes and dynamic capacities by leveraging:
Hot-swappable modular output power
Hot-swappable modular communications
Modular input power
MPX Benefits
Adaptive capacity, distribution, monitoring, control and
management of critical devices
Flexibility to respond to constant change—redeploy modules
to suit changing needs
Buy only what you need and build on your investment
Secure communication
Reconfigurable Power Capacity & Distribution
The MPX rack PDU has a scalable design that allows onsite configuration to fit immediate IT equipment needs. It is the perfect choice to respond to the needs of a growing data center. Relocate or add IT equipment to support changing needs, by easily reconfiguring the power input
and distribution.
Designed for Critical Environments
Critical rack space operating temperature—up to
55˚C / 131˚F to support hot internal rack environments
Accurate power metering of +/-1% voltage & current for
assured oversight
Energy and power metering down to the individual
receptacle
Comprehensive alarming including notification of
overloaded branch circuits
Environmental sensing with threshold and alarm set-points
Notification on the loss or removal of individual rack
equipment loads
Fits Needs Now And Later
The MPX rack PDU provides a wide selection of single phase and three-phase power input configurations—with the ability to field change while maintaining distribution infrastructure.
Power Rail Spacer
Power Rail Chassis
Branch Receptacle Modules
BDM™ local display module
Communications Module (RPC2)
MPX PEM variable
capacity module
MPX PEM fixed
capacity module
(MPX™ BRM)
SN Sensors
(MPX PRC)
Power Entry Module (MPX PEM)
14
MPH2—Managed Rack PDU: Advanced Monitoring And Control Support
MPH2 is the most intelligent, high-availability line of managed rack PDUs. It offers remote monitoring and control capabilities as well as environmental input options, with multiple power input selections and output
configurations.
It is available in the following four versions:
Outlet Level Metered and Switched Outlet Level Metered Rack PDU Metered and Outlet Switched Rack PDU Metered
MPH2 Benefits
Monitors electrical and environmental parameters
with set threshold and alarm tools Controls and manages individual receptacles and/
or groups of loads and devices Allows you to predict failing conditions before
they occur and proactively manage connected equipment for maximum uptime
Energy and power metering to maximize the data center power and cooling infrastructure
Lowest power consumption of all switched rack PDU designs ensures lower operating costs for datacenter
Up to four MPH2 rack PDUs may be Interconnected as a Rack PDU Array™, consolidating
user IP connections and device monitoring.
Designed for Critical Environments
Industry leading operating temperature
—up to 60˚C / 140˚F to support hot Internal rack environments Bi-stable relays ensure basic power distribution in the event that intelligence is compromised Accurate power metering of +/-1% voltage & current for assured oversight Energy and power metering down to the individual receptacle Comprehensive alarming including notification of overloaded branch circuits
Environmental sensing with threshold and
alarm set-points Notification on the loss or removal of individual rack equipment loads
Communications Module
(RPC2™):
Provides upgradable network
communications, sensor and
local display interface
BDM™ local display
module: Advanced
diagnostics, displayed at a
location that is convenient
for the customer. Features
include specific information
on alarms, specific labels
for outlets
Onboard display:
easy access to vital information
Slim profile breakers:
100% rated hydraulic
magnetic slim profile. CB’s
provide reliable resettable
branch circuit protection
without nuisance tripping
Provides
at the rack
Locking outlets and locking power cord:
Prevents accidental unplugging of IT devices
SN Sensors: consolidate
environmental monitoring of temperature and humidity with rack level power
Flexible power cord entry: Simplifies
installation of higher amperage units
Corded and hardwired options:
wiring to both overhead and raised floor power distribution
provide flexibility of
Rack PDU
15
Enhanced Performance And Management Of Dynamic IT Spaces
MPH2™ and MPX™ intelligent rack PDUs can be managed both locally and remotely. Metering of all electrical information down to the outlet, phase, bank or rack PDU level as well as integration with environmental sensors makes these rack PDUs the backbone of rack level power consumption and environmental information. Support for all major industry-standard management, authentication and encryption standards and protocols ensure that these products seamlessly fit into any existing network and security architecture.
Flexible Local & Remote Management
The MPH2 standard onboard display provides all pertinent information required at the rack. The optional BDM local display is available for MPH2 or MPX, and provides flexibility in location of the display for most convenient visibility.
Remote communications at a rack PDU level is enabled by the modular, hot swappable RPC2™ card, providing seamless upgradeability and serviceability. RPC2 enables:
Support up to 4 PDUs within a Rack PDU Array™: Minimizes IP addresses Support up to 10 environmental sensor probes: Consolidated rack level power and
environmental monitoring Support for Web UI, CLI, SSH and Telnet: Provides Windows, Linux and network administrators their preferred way to interact with the rack PDU
Support for all major remote authentication & encryption protocols:
Ensures seamless integration into any corporate security architecture SNMP v1, v2 and v3 support: Ensures secure communications through network management systems IPv4 and IPv6 support: Ensures continued IP support for rack PDUs Embedded data log: Enables equipment or rack level baseline power consumption study Embedded event log: Easier troubleshooting and auditing
Remote monitoring interface capabilities include:
Snapshot of all electrical parameters at outlet, branch, phase and aggregate level Snapshot of environmental sensor readings and status
Threshold conguration, alarm creation and notications
Power control of individual or group of outlets Status information and conguration of all outlets Network management settings
Centralized Management of all rack PDUs within a datacenter is provided by Avocent
Rack Power Manager
Centralized power consumption and environmental reports at all levels within datacenter Centralized power control of individual or group of outlets Mass configuration capabilities Centralized authorization, authentication and auditing of all rack PDUs and pertinent data
Out of band access and control solutions
Avocent
Advanced
Console Server
Avocent DS View 4
Avocent
MergePoint Unity
RPC2™
Communications
Module
Critical Equipment
Monitoring Solutions
Liebert Nform
Liebert SiteScan
rd
party apps
3
(SNMP)
DCIM
Avocent Universal
Management
Gateway
Trellis
MPX™ and MPH2™ rack PDUs fully integrate into Emerson Network Power’s industry-leading KVM, serial console and infrastructure management systems.
Integration with Avocent® Advanced
Console Server, MergePoint™ Unity KVM Switches ensures:
Out of band management path for rack PDUs Rack PDUs are a part of consolidated rack level access and control solution Minimize the number of IP addresses required for rack PDU management
Integration with Avocent DSView4™ software ensures:
Rack PDUs are a part of consolidated datacenter level access and control solution Easy association of IT equipment with the rack PDU outlets they are connected to Rack PDUs are a part of consolidated authentication, authorization and audit solution for datacenters
Integration with Liebert® Nform™ and
Liebert SiteScan® ensures:
Rack PDUs are a part of consolidated facilities level monitoring solution for datacenters Real-time monitoring and control of virtually any piece of critical support equipment Data analysis and trend reporting Event management
Integration with the Trellis™ platform
and Universal Management Gateway
appliances ensures that rack PDUs are a
part of a comprehensive DCIM solution that includes:
Inventory Management of all IT and facilities assets Monitoring of all facility critical devices and service processor-enabled IT devices Capacity & Change Management Energy Consumption Management Power System Management
16