Emerson Hd60002 Owner's Manual

Part. No. SP6295 Printed in Canada
CAUTION: Read all instructions carefully before installation.
Save this Owner’s Manual for future reference.
Model No. HD6000-2
Moist
AIR
EMERSON
®
SP6295 - HD6000-2 Eng - 71234 7/12/05 3:24 PM Page 1
Safety Signal Words
DANGER: means if the safety information
is not followed, someone will be seriously injured or killed. WARNING: means if the safety informa­tion is not followed, someone could be seriously injured or killed. CAUTION: means if the safety information is not followed, someone may be serious­ly injured or killed.
1. To reduce the risk of fire or shock haz­ard, plug humidifier directly into a 120V , A.C. electrical outlet. Do not use extension cords.
2. Keep the electric cord out of traffic areas. To reduce the risk of fire haz­ard, never put the electric cord under rugs, near heat registers, radiators, stoves or heaters.
3. Always unplug the humidifier before moving it, before cleaning, or whenev­er the humidifier is not in service.
4. Keep the humidifier clean.
5. Do not put foreign objects inside the humidifier.
6. Never use your humidifier while any part is missing or damaged in any manner.
7. To reduce the risk of electrical hazard or damage to humidifier, do not tilt, jolt or tip humidifier while unit is running.
8. To reduce the risk of damage to humidifier, unplug humidifier, when water reservoirs are empty or when the humidifier is not in use.
9. To reduce the risk of accidental electri­cal shock, do not touch the cord or controls with wet hands.
10. Note the warning label shown below.
WARNING: To reduce risk of fire, elec­tric shock, or injury always unplug before filling, servicing or cleaning.
GENERAL SAFETY INSTRUCTIONS
Limited Warranty
All products covered by this Owner’s Manual are warranted against defects in workmanship and materials for one year from the date of sale except for motor, which is warranted for two years.
This warranty does not apply to damage from accident, misuse or alteration nor where the connected voltage is more than 5% above the nameplate voltage, nor to the equipment improperly installed or wired or maintained in violation of this Owner’s Manual. No other written or oral warranty applies. No employee, agent, dealer or other person is authorized to give any warranties on behalf of Emerson Electric.
The customer shall be responsible for all costs incurred in the removal or reinstallation and shipping of the product for repairs. Within the limitations of this warranty, inoperative units should be returned, freight prepaid to a repair center and we will repair or replace, at our option, at no charge to you with return freight paid by Emerson. It is agreed that such repair or replacement is the exclusive remedy available from Emerson Electric Co. and that Emerson Is Not Responsible For Damages Of Any Kind, Including Incidental And Consequential Damage. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you.
The warranty gives you specific legal rights, and you may also have other rights which vary from state to state or province to province.
Sales receipt required as proof of purchase for warranty claims.
2
Table of Contents
Warranty Information...............................2
General Safety Instructions.....................2
To Save AService Call ............................2
Know Your Humidifier..............................3
Humidifier Operations ..............................3
Location Instructions................................4
Electrical Hook-Up ...................................4
Water Fill..................................................4
Operating Humidifier Controls.................6
Using Your Humidifier..............................6
Cleaning of Your Humidifier .....................7
Care of Filter............................................8
Trouble Shooting.....................................9
Repair Parts......................................10-11
To Save a Service Call
Check the following if your humidifier will not operate.
1. Is power cord attached to outlet?
2. Is there electrical power to outlet?
3. Is airflow control in operating position?
4. Is humidity control set high enough?
SP6295 - HD6000-2 Eng - 71234 7/12/05 3:24 PM Page 2
CAUTION: Use only EPA Registered Bacteriostat, available at your local store. Under no circumstances should you use water treatment products designed for Roto belt or Ultrasonic humidifiers.
CAUTION: Keep your humidifier clean. While humidifiers do not cause colds, some studies suggest that dirty humid­ifiers can cause cold-like symptoms in some people. To reduce the risk of this, we recommend you clean your humidi­fier weekly and use EPAregistered bac­teriostat treatment.
Description HD6000
Output/24 hrs 6 Gallons
(22.7 Litres)
Reservoir Capacity (each) 1.7 Gallons
(6.4 Litres)
* Sq. Ft. Coverage 1300
Fan Speeds 3 Filters 1 (HDC-1) Fill Light No Automatic Shut Off No Auto Humidistat Yes CUL Listed Yes Volts 120 A.C. Hertz 60 Amps 1.14 Watts 65
Know Your Humidifier
Humidifier Operations
3
Your new Moist AIR humidifier is designed to satisfy home humidity requirements through the principle of evaporation of water into the air. After water is added to the unit, the filter begins to soak up the water and become totally saturated in approximately 30 min­utes. Air is drawn in from the back of the humidifier by means of a circulation fan and drawn through the filter. As air passes through the filter, moisture is absorbed by the air and then released in the form of vapor. No water droplets will enter the home. All evaporation into the air takes place in the humidifier, which means that the residue left by evaporating water is not passed into the home, but remains in the filter.
Water Reservoir
Controls
Water Reservoir
Grill
Base
Moist Air
Water
Filter
Dry
Room
Air
* Based on an area with average insulation
and an 8 foot ceiling height.
SP6295 - HD6000-2 Eng - 71234 7/12/05 3:24 PM Page 3
WARNING: For your own safety, do not use humidifier if any parts are dam­aged or missing.
Step 1
Place humidifier in area of house where most humidity is needed, or one which would likely result in moist air being circulated throughout the house such as near a cold air return. Moist air (humidity) produced will disperse into the whole house, but area closest to the unit will have the highest humidity.
WARNING: To reduce the risk of shock, always unplug humidifier before mov­ing it. Even turned off, a plugged in humidifier still has electricity in it.
Use the bottom of the base to lift and carry the humidifier as shown. Be sure the water reser­voirs are properly attached before moving.
IMPORTANT: Keep the reservoirs tight against the housing between them. If you don’t, the reservoirs may detach from the base. The
humidifier could come apart and fall.
Step 2
The humidifier should be positioned with the back (cord exit side), at least 2 inches away from the wall. Air needs to enter through louvers in the rear panel in order for the humidifier to operate at peak efficiency. NOTE: Due to release of cool, moist air from humidifier, it is best to direct air away from home thermostat. It is best to position humidifier next to an inside wall. Hot air registers and cold air from outside walls can affect the efficiencies of the controls. Unit should not be placed where warm air from a hot air register blows directly on unit.
Water Fill
WARNING: To reduce the risk of shock, always unplug humidifier before cleaning or servicing.
Step 1
Remove water reservoir as shown. Pivot the reservoir away from the unit by pushing in at the bottom, and pulling the handle. This will disengage two locking tabs at the base of the reservoir.
Step 2
Lift the water reservoir vertically to remove from the unit.
WATER
RESERVOIR
BASE
(LIFT HERE)
1
2
1
LIFT UP
PULL OUT
PUSH IN
Location Instructions
4
Locate nearest 120V A.C. wall socket in the location desired, preferably on inside wall. Plug in the electrical cord.
WARNING: To reduce the risk of fire or shock hazard, do not use extension cords. Humidifier should be plugged directly into a 120V A.C. outlet.
To reduce the risk of electrical shock, this humidifier has a polarized plug (one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug
does not fit fully in the outlet, reverse plug. If it still does not fit, contact a qualified elec­trician to install the proper outlet. Do not change the plug in any way.
Electrical Hook-Up
SP6295 - HD6000-2 Eng - 71234 7/12/05 3:24 PM Page 4
Loading...
+ 8 hidden pages