What You Should Know Before Beginning
TROUBLESHOOTING
WARRA NTY INFORMATION
®
®
Guía de instalación rápida Guide d’installation rapide Kurzanleitung Snelle installatiegids Guia de instalação rápida
Hurtig installationsvejledning Guida di installazione rapida
This is a quick reference guide. Please refer to the complete Installation, Care & Use Manual for specifics including warnings, cautions and dangers. If after reading the troubleshooting section, you still have questions about parts, installation or warranty, please visit
www.insinkerator.com
Please have the model and serial number of your tank and tap available when calling. Visit www.insinkerator.com for assistance on many common questions.
BEFORE INSTALLINGREPLACEMENT TAP
Personal Injury: Unplug the tank. Depress the tap
handle for about one minute so cold water can flow through the unit. This cools the water for safer removal of existing tank and tap. Remove the drain plug on the tank bottom to empty all remaining water.
• A continuous electrical power source (not controlled by a wall switch) is required to power the unit.
• Ensure that there is sufficient space to fit the unit under the sink and around existing plumbing.
• For HC1100 tap installation, a 35mm–38mm hole is required; for the GN1100 and H990 tap, the hole requirement is 32mm–38mm. Many installers choose to use the existing “sprayer” hole.
• Check to make sure that a cold water supply line is within reach of the water inlet line.
Starting the Installation Process
WHAT TODO
Water and steam spits forcefully from spout without turning on the tap.
Water is not hot
• Unit is boiling.
May be normal during initial setup.
• The unit may not be plugged in.
• The electric outlet is inoperative.
Depress tap lever to release some water from the tank.
• Adjust water temperature using dial on tank front.
Remember that at higher altitudes, water boils at lower temperatures.
See Owner’s Manual
Make sure the unit is connected to a properly earth (grounded) electric outlet.
• Make sure the circuit breaker or fuses are functioning properly.
• Check that the outlet is not switched off.
Water is too hot or not hot enough
• Thermostat is not adjusted to your needs.
Adjust the thermostat slowly, then depress or twist tap handle for 20 secs. to bring in fresh water at the new setting. Allow 5-7 minutes for water to reach new temperature.
Water comes out the vent instead of spout
• Outlet tube is blocked.
Check that outlet tube is not kinked, twisted or pinched.
Unscrew spout end piece and clean out any debris.
Water is dripping from the spout/vent intermittently
• The expansion chamber isn’t draining properly due to low water pressure.
• The spout is blocked.
• Unplug the unit.
If the dripping doesn’t stop after a few minutes, check the supply valve to ensure that it is fully open and there are no obstructions in the water line reducing the pressure below
172 kPa (1.7 bar; 25 psi).
i.e., a poorly mounted saddle valve, a clogged water filter, or a partially opened shut-off valve.
Unscrew spout end piece and clean out any debris.
Water is dripping from the spout/vent constantly
• Debris in the water line may be in the tap valve seat causing a slow water leak.
Unscrew spout end piece and clean out any debris.
Depress or twist lever 7-10 times to flush tap & lines.
Divided stream
• Debris in the end piece.
Unscrew spout end piece and clean out any debris.
PROBLEM POSSIBLE CAUSE
FILTRATIONISSUES
If you are still experiencing trouble,visit www.insinkerator.com
PN 43899
Water taste or odour
New filter doesn’t fit
The filter leaks
No water flow or low water flow
Filter water flow direction is wrong
Filter needs to be flushed out
Life of filter has expired
• Head & bracket not fully rotated
• Filter O-ring breach
• Head & bracket not fully rotated
• Filter O-ring breach
• Life of filter has expired
• Review filter tube connection instructions.
• Depress/twist tap and run until the water is cold.
• If no change, replace filter cartridge.
• Take out the new filter, put in old filter.
• Remove, inspect, reinstall filter cartridge.
• Test unit by reinstalling old filter and rotating to full stop. Check for leaks.
• Replace filter cartridge.
A steaming hot water tap, like any water heater, has a limited life and will eventually fail. To avoid possible property damage, this steaming hot water tap should be regularly examined for leakage and replaced when necessary. A drain pan, plumbed to an appropriate drain or outfitted with a leak detector, should be used in those applications where any leakage could cause property damage.
Covers all replacement parts and labour to correct defects in material or workmanship in the tap system, excluding the replaceable filter cartridge, for the full warranty period from the date of installation in your home. If warranty service is required during the warranty period, contact an authorized InSinkErator
®
service agent to replace or repair the unit in your home at no cost to you. If your tap is replaced rather than repaired, the warranty on the new unit shall be for the duration of the remaining portion of the original tap warranty. Note: Warranty is determined by unit serial number and/or date of installation. Purchase or installation receipt may be required to verify warranty status. To find the location of your nearest factory authorized service center, please see attached service agent list.
The foregoing warranty does not apply to damage or inoperation resulting from accident, alteration, misuse, abuse, improper installation, installation not in accordance with these instructions or local electrical and/or plumbing codes. We do not assume any responsibility for consequential damage. Install using genuine InSinkErator manufactured components only. Use of non InSinkErator components will void your warranty.
Tap: Series 1100, 2-year warranty
H990, 1-year warranty
Tank: 2-year warranty on stainless steel tank
www.insinkerator.com
LED green light on front of tank does not illuminate
• The unit may not be plugged in.
• The electric outlet is inoperative.
• Make sure the circuit breaker or fuses are functioning properly.
• Check that the outlet is not switched off.
H990
HC1100/ GN1100
A
B
C
D
6
A
B
C
A
B
A
A A
B B
B
C C
blue tube
DO NOT plug in unit until
water flows from tap
A
B
H990
HC1100/GN1100
leave 6.4 mm
exposed
Hang tank and tighten screws
with only
1/2 turn
clockwise.
Turn screws
until snug.
FILTRATION STANDARD ON HC1100 & GN1100
OPTIONALON H990
Typical Complete Installation
B
1
small white tube
2
3
400 mm or less
from tap base
and
760 mm or less
from standard
grounded outlet
From water supply
To tap
See Installation, Care & Use Manual for important cautions, warnings and dangers
DO NOT extend plumbing
or electrical lines
Turn off cold water supply
Quick & Easy Steps to Steaming Hot Water
white tube
Press ALL tubes inonce again to ensure secure fit.
O-Ring
Wing nut
Rubber gasket
white tube from filter white tube from filter
white tube white tube
A
copper tube
Hex Tool
(included)
Tank must be mounted
level.
A
Make sure to use
rubber gasket
to ensure proper seal.
GN1100
HC1100
H990
Property Damage: Make sure bends in all water lines are smooth and unkinked, with no pinching, twisting or blockage. Pinched or blocked water lines may cause damage to the dispenser tank.
Electric Shock Hazard:This applianceMUST be earth (grounded). Using an ungrounded appliance can result in serious injury or death from electric shock. Improper connection of the equipment grounding conductor can result in the risk of shock by electricity.
To prevent damage or unit operating properly, the water pressure must be between 172 kPa - 862 kPa (1.7 bar - 8.6 bar; 25 psi - 125 psi)
B
copper tube
Quick Connect Fitting John Guest Fitting
®
www.insinkerator.com
Loading...