Emerson CF980MAB 00, CF980MBX 00 User Manual

Page 1
READ AND SAVE THESE INSTRUCTIONS
Model No.
CF980MAB 00 CF980MBX 00
EMX
TUREEN
Part No. F40BP73530000 Form No. BP7353
Net Weight: 35.8 Lbs.
Damp Location
Ceiling Fan
Owner's Manual
LIMITED WARRANTY
What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered.
What The Period Of Coverage Is:
As it applies to the motor, this warranty will last for a lifetime of your ceiling fan. All other components and accessories are covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.
What Will Emerson Electric Co. Do To Correct Problems:
Emerson Electric Co. will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no charge to you. If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson Electric Co. will refund the actual purchase price of your fan. We will ship the repaired product or replacement to you at no charge, but you are responsible for all costs or removal, reinstallation and shipping of the product to Emerson Electric Co.
How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division of Emerson Electric Co., 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product with your request.
• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center.
You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage.
What Is Not Covered:
The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does not cover any defects, malfunctions or failures caused by:
• Repairs by persons not authorized by Emerson Electric Co.,
• Use of parts or accessories not authorized by Emerson Electric Co.,
• Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or
• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.
Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:
• The original purchaser or user ceases to own the product, or
• The fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no employee, agent, dealer or other person is authorized to give any warranties on behalf of Emerson Electric Co.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to such damages as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if this product does not work properly.
How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
FOR CANADA, THIS FAN MUST BE SECURED DIRECTLY TO THE BUILDING STRUCTURE/CEILING JOIST.
DO NOT SECURE THIS FAN TO AN OUTLET BOX.
Page 2
2
WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.
Safety Instructions
1. Read your owner’s manual carefully and keep it for future reference
2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.
3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.
4. Do not put anything into the fan blades while they are turning.
5. Do not operate reversing switch until fan blades have come to a complete stop.
Additional Safety Instructions for Installation
1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.
2. All wiring must be in accordance with the National Electrical Code “ANSI/NFPA 70-1999” and Local Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.
3. The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support of 50 lbs. or less”, and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
4. The downrod furnished with the fan proves the minimum recommended floor-to-fan blade clearance for an 8 foot ceiling.
5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with th fan blades.
6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.
CAUTION: The halogen bulb operates at high internal pressure and high surface temperatures and could shatter unexpectedly. The halogen bulb generates UV (ultraviolet) radiation that may cause skin and eye irritation with prolonged exposure. To avoid risks of burns or other injury, assure power is off before attempting to install or replace halogen bulb. Do not operate fan/light without lower glass in place.
7. This fan uses a halogen bulb. Do not touch the bulb with bare hands. Fingerprints may result in shorter bulb life. Remove fingerprints with alcohol.
8. Use only with light kits marked Suitable For Use in Damp Locations.
NOTE: This fan is suitable for use with solid-state speed controls. WARNING: To reduce the risk of fire or electrical shock, this fan should only be used with fan speed
control, Model No. SW105, manufactured by Rhine Electric Co., Ltd. WARNING: This product is designed to use only those parts supplied with this product and/or any
accessories designated specifically for use this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson could result in personal injury or property damage.
WARNING: To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
WARNING: To reduce the risk of electrical shock, this fan must be installed with a general use, isolating control/switch.
WARNING
!
DATE CODE:
The date code of this fan may be found on the box, stamped in ink on a white label. You should record this data above and keep it in a safe place for future use.
THIS FAN IS SUITABLE FOR DAMP LOCATIONS SUCH AS
COVERED PORCHES, COVERED PATIOS, AND COVERED DECKS. . .
ANYWHERE THERE IS A ROOF OVERHEAD.
Page 3
Tools Needed for Assembly
One Phillips head screwdriver One stepladder
MATERIALS
Wiring, outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of the following sizes:
Unpacking Instructions
For your convenience, check-off boxes are provided next to each step. As each step is completed, place a check mark in the box. This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted.
1. Open styrofoam unit containing fan. Remove top
half of styrofoam unit. Remove parts and check to see that you have received the following parts:
NOTE: If you are uncertain of part description, refer to exploded view illustration.
a. One ceiling cover b. One hanger bracket c. One hanger ball/downrod assembly d. One coupling cover e. Fan motor and housing assembly f. Four blade flanges g. Four fan blades h. One light kit assembly i. Three 50-watt, MR-16, GU-10 halogen bulbs j. One light kit glass k. One SW114 wall control/3 wall control covers l. One loose parts bag containing:
1. Thirteen #10-24 x 1/4” oval head blade screws
2. Nine 1/4-20 x 1/2” oval head flange screws
3. Two 1-1/4” threaded studs
4. Two knurled knobs
5. Two lockwashers
7. One hairpin clip
8. One clevis pin
9. Four #10-24 x 1” lower housing screws
10. Four #10-24 x 5/16” pan head screws
m. One SW105 receiver n. One lower housing
3
NOTE: Place the parts from the loose parts bags in a small container to keep them from being lost. If any parts are missing, contact your local retailer or catalog outlet for replacement before proceeding.
Before assembling your ceiling fan, refer to section on proper method of wiring your fan (page 8). If you feel you do not have enough wiring knowledge or experi­ence, have your fan installed by a licensed electrician.
WARNING
!
Do not install or use fan if any part is damaged or missing. Call Toll-Free:
1-800-654-3545
This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
WARNING
!
WARNING
!
Installed Wire Length Wire Size A.W.G.
Up to 50 ft. 14
50-100 ft. 12
This Manual Is Designed to Make it as Easy as Possible for You to
Assemble, Install, Operate and Maintain Your Ceiling Fan
b.
c.
d.
a.
n.
h.
i.
j.
e.
m.
H
I
H
I
L I G
H
T
M
E
D M E
D
L
O
W L O
W
R
E V
R
E V
F A
N
O F
F
f.
k.
g.
l.
Page 4
4
Electrical Requirements
Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.
The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.
To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support of 50 lbs. or less”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
WARNING
!
Ceiling Fan Procedures
General
Your Emerson Ceiling Fan/Light Wall Control consists of a wall mount transmitter. The SW114 transmitter works in conjunction with the SW105 Receiver (purchased separately). The receiver is mounted under the fan ceiling cover. The wall control is designed to separately control your ceiling fan speed, direction, uplight and downlight intensity, page 11.
Code switches in the wall control and receiver may be set in 16 different positions. If your fan and light go on and off without using your control, you may be getting interference from other transmitters such as garage door openers, car alarms or security systems. To remedy this situation, simply change the combina­tion code in your wall control and receiver.
If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
WARNING
!
1. Remove the fan motor and housing assembly from
the styrofoam packaging and position it so that the bottom of the motor is facing you.
2. Position the bottom styrofoam section on a flat
surface exposing the large center hole for fan motor placement. Place the fan motor housing into the hole so that the bottom of the motor is facing up. Position the lower housing over the fan motor (Figure 1). The styrofoam section will hold the assembly while you perform the following steps.
3. Install the lower housing onto the fan motor by
orientating the three protruding keys into the slots on the lower housing to secure. Fasten the lower housing onto the fan motor using the three #10-24 x 1” lower housing screws (Figure 2).
Figure 2
Figure 3
4. Connect the fan motor blue wire to the blue wire
from the light kit assembly; connect the fan motor white wire to the white wire from the light kit assembly (Figure 3).
Figure 1
LOWER HOUSING
FAN HOUSING
FAN MOTOR
#10-24 x 1" LOWER HOUSING SCREW (3)
LOWER HOUSING
PROTRUDING KEY (3)
LIGHT KIT
LIGHT KIT WHITE WIRE
FAN MOTOR WHITE WIRE
BLUE WIRE
FAN MOTOR BLUE WIRE
LIGHT KIT ASSEMBLY
Page 5
5
CAUTION: Before installing and tightening the screws, be sure there are no wires pinched between the bottom of the light kit assembly and fan motor.
5. Install the three #10-24 x 5/16” pan head screws to
secure the light kit assembly to the lower housing (Figure 4).
Figure 4
6. Carefully turn the partially assembled fan motor
housing onto the styrofoam section. The styrofoam section will hold the assembly while you perform the following steps.
7. Remove the hanger ball from the downrod by
loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 5). Remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in Step 15.
8. Separate, untwist and unkink the three motor leads.
Route the motor leads through the downrod and seat the downrod in the motor coupling (Figure 6).
Figure 5
Figure 6
10. Install the two setscrew (supplied) in the motor
coupling (Figure 6). While pulling up on the downrod, tighten the setscrews using the setscrew wrench (supplied).
NOTE: The setscrews must be properly installed as described above, or fan wobble could result.
11. Mount the blade flanges to fan blades using three
#10-24 x 1/4” oval head blade screws per blade (supplied) (Figure 7). Repeat for all blade/flange assemblies.
NOTE: Be sure to position the flange onto the blade with the ribs side up.
It is critical that the clevis pin in the motor coupling is properly installed and the setscrew is securely tightened. Failure to verify that the pin and setscrew are properly installed (as shown in Figure 2) could result in the fan falling.
WARNING
!
To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
WARNING
!
9. Align the clevis pin holes in the downrod with the
holes in the motor coupling. Install the clevis pin and secure with the hairpin clip (Figure 6). (Pin and clip are supplied in loose parts bag.) The cle­vis pin must go through the holes in the motor cou­pling and the holes in the downrod. Push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull the downrod to make sure the clevis pin is properly installed.
Figure 7
NOTE: Take care not to scratch fan housing when installing blades.
#10-24 x 5/16" PAN HEAD SCREW (3)
LIGHT KIT ASSEMBLY
SETSCREW (2)
CLEVIS PIN
CLEVIS PIN
MOTOR COUPLING
HAIRPIN CLIP
DOWNROD
HAIRPIN CLIP
MOTOR COUPLING
SETSCREW (2)
LOWER HOUSING
HANGER BALL
PIN
DOWNROD
SETSCREW
#10-24 x 1/4" OVAL HEAD BLADE SCREW (3 PER BLADE)
FLANGE
BLADE
Page 6
6
12. Position one of the blade assemblies onto the
motor hub and secure blade assembly using two 1/4-20 x 1/2” oval head flange screws (provided). Repeat for all blade assemblies (Figure 8).
13. Slide the coupler cover over the downrod
and position it to cover the motor coupling (Figure 9).
14. Position the ceiling cover over the downrod. Be
sure the cover is oriented correctly, with the large opening at the top (Figure 9).
Figure 8
Figure 9
It is critical that the pin in the hanger ball is properly installed and the setscrews securely tightened. Failure to verify that the pin and setscrews are properly installed could result in the fan falling.
WARNING
!
15.Reinstall the hanger ball on the downrod (Figure
10) as follows. Route the motor leads through the hanger ball and slide the hanger ball over the downrod. Install the pin through the holes at the top of the downrod and slide the hanger ball up the downrod, aligning the ball so the pin in cap­tured in the groove in the top of the hanger ball. Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball. A loose setscrew could create fan wobble.
16.The fan comes with blue, black and white leads
that are 80-inches long. Before installing the fan, measure up approximately 6 to 9-inches above top of hanger ball/downrod assembly. Cut off excess leads and strip back insulation 1/2-inch from end of leads.
17. You have now completed the assembly of your
new ceiling fan. You can now proceed with hang­ing and wiring your fan.
Figure 10
1/4-20 x 1/2" OVAL HEAD FLANGE SCREW (2 PER FLANGE)
BLADE ASSEMBLY
PIN
HANGER BALL
DOWNROD
COUPLING COVER
CEILING COVER
DOWNROD
SETSCREW
Page 7
7
2. Carefully lift the fan and seat the hanger ball/down-
rod assembly on the hanger bracket that was just attached to the outlet box (Figure 13). Be sure the groove in the ball is lined up with the tab on the hanger bracket (Figure 12).
Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard.
WARNING
!
Figure 13
To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and hanger bracket.
WARNING
!
How to Hang Your Ceiling Fan
Figure 11
The fan must be hung with at least 7' of clearance from floor to blades (Figure 11).
WARNING
!
TWO SCREWS SUPPLIED WITH OUTLET BOX
HANGER BRACKET
TAB
OUTLET BOX
Figure 12
The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs. Use only a U.L. outlet box listed as “Acceptable for Fan Support of 50 lbs. or less”.
WARNING
!
Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until bracket contacts box. If bracket and/or outlet box are not securely attached, the fan could wobble or fall.
WARNING
!
1. Securely attach the hanger bracket to the outlet
box using the two screws supplied with the outlet box. (Figure 12.)
AT LEAST
7'
CEILING
FLOOR
NOTE: CEILING COVER, SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY.
OUTLET BOX
HANGER BRACKET
HANGER BALL/ DOWNROD ASSEMBLY
Page 8
8
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse or circuit breaker box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
WARNING
!
Figure 14
If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician.
CAUTION: To reduce the risk of electrical shock, disconnect the electrical supply circuit before installing the fan and light kit or receiver.
1. Pull the wire leads, coming from the end of the
downrod, and the supply wires through the open side of the hanger bracket. (Figure 14).
2. Position the SW105 Receiver (supplied) in the ceil-
ing cover so that the flat side of the receiver faces up and the open portion of the receiver is to the right, as shown in Figure 14.
3. Using wire connectors (supplied), make wiring con-
nections as follows (Figure 14 and 15):
a. Connect the white fan wire and the white supply
wire to the white receiver wire (AC IN/ MOTOR N).
b. Connect the black fan wire to the black receiver
wire (TO MOTOR L).
c. Connect the black supply wire to the black/white
receiver wire (AC IN L).
d. Cut off the ends of the blue and yellow receiver
wires and strip back insulation 1/2-inch from the ends of the wires.
e. Connect the blue fan wire to the blue receiver
wire (BOTTOM LIGHT).
f. Connect the green ground wires from the hang-
er bracket and the hanger ball to the supply ground wire (bare or green).
NOTE: Do not use capped yellow wire.
How to Wire Your Ceiling Fan
HANGER BRACKET
HANGER BRACKET GROUND WIRE (GREEN)
HANGER BALL GROUND WIRE (GREEN)
OUTLET BOX
BLACK SUPPLY WIRE
BLACK FAN WIRE
BLACK/WHITE RECEIVER WIRE
BLUE FAN WIRE
BLUE RECEIVER WIRE
SUPPLY GROUND WIRE (GREEN OR BARE)
RECEIVER
WHITE SUPPLY WIRE
CEILING COVER
OPEN PORTION
OF RECEIVER
HERE
WHITE FAN WIRE
WIRE CONNECTOR
YELLOW RECEIVER WIRE
DO NOT USE
BLACK RECEIVER WIRE
WHITE RECEIVER WIRE
Page 9
9
Figure 16
SW105
Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result.
WARNING
!
4. Carefully turn the wires upward and insert them up
through the open side of the hanger bracket and into the outlet box. Push the green and white wires into one side of the outlet box; push the black, blue and yellow wires into the other side of the outlet box.
Figure 15
To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling.
WARNING
!
5. Screw the two 1-1/4” threaded studs (supplied)
into the tapped holes in the hanger bracket (Figure 17).
6. Lift the ceiling cover up to the threaded studs and
turn until studs protrude through the holes in the ceiling cover (Figure 17).
7. Secure the ceiling cover in place by sliding
lockwashers (supplied) over the threaded studs and installing the two knurled knobs (supplied). (Figure 17.) Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod. Your fan is now wired to be turned on and off from the fan switch.
Figure 17
RECEIVER
BLACK SUPPLY
TO
110V
SUPPLY
WHITE RECEIVER WIRE
BLACK RECEIVER WIRE BLACK/WHITE RECEIVER
WHITE FAN WIRE
BLACK FAN WIRE
DOWNROD
OUTLET BOX
WHITE SUPPLY WIRE
BLUE RECEIVER WIRE BLUE FAN WIRE
YELLOW RECEIVER WIRE
DO NOT USE
1-1/4" THREADED STUD
KNURLED KNOB
CEILING COVER
LOCKWASHER
HANGER BRACKET
RECEIVER
CEILING COVER
Page 10
2. Place the glass onto the light kit assembly aligning
the three flat areas on the top flange of the glass with the three pins on the inside of the assembly (Figure 19). Then turn the glass clockwise until it stops turning.
3. Your ceiling fan is now installed and wire to be
controlled by your remote control system.
10
Figure 18
Figure 19
1. Do not touch the new 50-watt (maximum) MR-16,
GU-10 bulb with your bare fingers; using a cloth or soft gloves to hold the bulb, gently push it into the socket and twist to lock the lamp into the socket (Figure 18). If there is any doubt that the bulb may have been contaminated by your touch, you should clean the bulb before its first use. Take a clean cloth dipped in a small amount of rubbing/isopropyl alcohol and gently brush off the bulb surface. If the lamp is hot, wait 30 minutes before cleaning.
CAUTION: To reduce the risk of electric shock, burns or other injury, disconnect the electric sup­ply circuit to the fan before attempting to install or replace the halogen bulb.
CAUTION: To not touch halogen bulbs with bare hands. Fingerprints may result in shorter bulb life. Remove fingerprints with alcohol.
Halogen Bulb and Glass Installation
LIGHT KIT SOCKET
LIGHT KIT ASSEMBLY
FLAT AREA (3)
GLASS
50-WATT MR-16, GU-10 HALOGEN BULB
Page 11
11
Setting Operating
Frequency of Wall Control
and Receiver (Figure 20)
Your wall control and receiver have code switches which must be set in one of 16 possible code combi­nations. The four levers (numbered 1, 2, 3, and 4) on the switches are factory-set in the ON (up) position. Change the switch settings as follows:
1. Slide the four switch levers in the wall control to
your choice of ON (up) or down positions. Use a ball-point pen or small screwdriver and slide the levers firmly up or down.
2. In the receiver, slide the four switch levers to the
same positions as set in the wall control. Make sure the levers on both switches are in the same positions, otherwise the fan will not operate.
Figure 20
The SW114 wall control transmits the command signals via radio waves to the SW105 receiver installed in the ceiling fan ceiling cover. The SW105 receiver is required for the SW114 wall control to function. Power for the SW114 wall control comes from the 12V battery, located in the wall control.
Replacement 12V batteries recommended are Duracell MN21 and Eveready A23.
1. Install the 12V battery (supplied) into the wall
control (Figure 21).
2. The SW114 wall control is supplied with a white,
ivory or almond color cover. Choose the style that best suits your needs and snap the cover onto the wall control (Figure 21).
Figure 21
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse or circuit breaker box.
WARNING
!
Installation
of Wall Control
3. Install the wall control onto the outlet box using the
supplied screws (Figure 22).
4. Install decorator wall plate (not included) using the
two screws provided with wall plate (Figure 22).
Figure 22
HI
HI
MED
MED
LOW
LOW
FA
N
O
F
F
SW105 RECEIVER
ON
1
WALL CONTROL LEVERS
LIG
H
T
REV
REV
234
CODE SWITCH
ON
1
234
RECEIVER SWITCH LEVERS
SW114 WALL CONTROL
CODE SWITCH
H
I
H
I
L
IG
H
T
M
E
D
M
E
D
L
O
W
L
O
W
R
E
V
R
E
V
FAN OFF
WALL CONTROL COVER
12V BATTERY
SW114 WALL CONTROL
DECORATIVE WALL PLATE (Not Included)
WALL PLATE SCREW (2)
OUTLET BOX
H
I
L
I G
H
T
M
E
D
L
O
W
R E
V
F
A N
O
F F
SW114 WALL CONTROL
WALL CONTROL SCREW (2)
Page 12
12
Figure 23
Trouble Shooting
Wall Control
Fan/Light Fails to Operate
• Check that the wall switch for the ceiling fan is in the “ON” position.
• Check that the battery is good (red indicator light should light when any button is pressed).
• Check that the receiver is wired properly.
• Check that both transmitter and receiver code switches are set in the same position.
Operating Your Ceiling Fan
IMPORTANT
Fan installation must be completed, including the installation of the fan blades, before testing of the wall control.
Your SW114 Fan/Light Wall Control (Figure 23) has full control of your fan, lights, and airflow direction.
1. To set the desired fan speed, push the HI, MED, or
LOW buttons to operate your fan on high, medium or low speed (See Figure 23).
2. To reverse the direction the fan is turning, press
the REV button. The direction the fan turns will change each time the REV button is pressed.
3. To turn your fan off, press the FAN OFF button.
4. To set the level of light brightness, press and hold
the LIGHT button. The light brightness will continue to increase then decrease while the button is held down. When the light is at the desired brightness, release the button.
5. To turn the light on or off, press and release the
LIGHT button. The light will turn on at the light level previously set (See Step 4).
Red indicator light turns on when any button is pressed. If the light does not come on, replace the battery.
Maintenance
IMPORTANT CARE INSTRUCTIONS
for your Ceiling Fan
Periodic cleaning of your new ceiling fan is the only maintenance that is needed.
When cleaning, use only a soft brush or lint free cloth to avoid scratching the finish.
Abrasive cleaning agents are not required and should be avoided to prevent damage to finish.
Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock.
WARNING
!
Accessories
1. Downrod Extension Kits (see store or catalog).
2. Ceiling Fan Controls (see store or catalog).
This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
The use of any other control not specifically approved for this fan could result in fire, shock and personal injury.
WARNING
!
WARNING
!
FAN SPEED BUTTONS
FAN OFF BUTTON
FAN OFF
HI
LIGHT
MED
LOW
REV
RED INDICATOR LIGHT
LIGHT BUTTON
AIRFLOW DIRECTION BUTTON
Page 13
13
INSTRUCTION TO THE USER (if device contains a digital device)
This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interfer­ence in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if no installed and used in accordance with the instructions, may cause harmful interference to radio communi­cations. However, there is not guarantee that interference will not occur in a particular installation. If this equip­ment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
This equipment has been certified to comply with the limits for a class B computing device, pursuant to FCC Rules. In order to maintain compliance with FCC regulations, shielded cables must be used with this equip­ment. Operation with non-approved equipment or unshielded cables is likely to result in interference to radio and TV reception. The user is cautioned that changes and modifications made to the equipment without the approval of manufacturer could void the user’s authority to operate this equipment.
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Page 14
Trouble Shooting
TROUBLE PROBABLE CAUSE SUGGESTED REMEDY
1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers.
2. Loose power line connections to the fan, or loose 2. Check line power connections to fan and switch wire switch wire connections in the switch housing. connections in the switch housing.
WARNING: Make sure main power is turned off.
3. Fan/Light Wall Control is OFF. 3. Turn ON Fan/Light Wall Control.
4. Code switches in wall control/receiver are 4. Check that both code switches are set in the same not set in the same position. positions.
2. Fan sounds 1. Blades not attached to fan. 1. Attach blades to fan before operating. noisy.
2. Screws securing fan blades to motor 2. Check to make sure the screws which attach the fan blades are loose. to the motor are tight.
3. Wire connectors inside switch housing rattling. 3. Check to make sure wire connectors in switch housing are
not rattling against each other or against the interior wall of the switch housing.
WARNING: Make sure main power is turned off.
4. Loose screws in motor housing. 4. Check to make sure all screws in motor housing are snug
(not over-tight)
3. Fan wobbles 1. Setscrew in motor coupling is not tightened 1. Raise coupling cover and tighten setscrew securely. excessively. securely.
2. Setscrews in the hanger ball/downrod 2. Tighten the setscrews in the hanger ball/downrod assembly. assembly are loose.
3. Screws securing fan blade to 3. Check to be sure screws which attach the fan blade motor are loose. to the motor are tight.
4. Fan blades are not seated properly. 4. Check to be sure the fan blade flanges seat firmly and
uniformly to the surface of the motor. If blades are seated incorrectly, loosen the blade screws and retighten.
5. Hanger bracket and/or ceiling outlet box is 5. Tighten the hanger bracket screws to the outlet box, and/or not securely fastened secure outlet box.
6. Fan blades out of balance. 6. Interchanging an adjacent (side-by-side) blade pair can
redistribute the weight and result in smoother operation. Or use supplied balancing kit to balance blades.
WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER
BEFORE TROUBLE SHOOTING YOUR FAN.
!
!
!
14
Page 15
15
Repair Parts
9
HI
HI
MED
MED
LOW
LOW
F A
N
O
F F
R
E V
R
E
V
L I
G
H T
1
5
6 7
3
2
10
4
8
11
16
17
19
18
23
14
20
21
12
13
15
24
22
Page 16
Air Comfort Products
DIVISION OF EMERSON ELECTRIC CO.
8100 W. Florissant St. Louis, MO 63136
Part No. F40BP73530000 Printed in China 10/07 Form No. BP7353
Repair Parts Listing
Part Numbers Key Model No. Model No. No. Description CF980MBX 00 CF980MAB 00
* Hanger Pack, Consisting of: 761655-67 761655-67 1 Hanger Bracket — 2 Hanger Ball — 3 Downrod, 8”
* Parts Bag Containing: 763415 763415 4 Setscrew Wrench — 5 Threaded Stud, 1-1/4” (2) — 6 Lockwasher (2) — 7 Knurled Knob (2) — 8 Pin, Clevis (1)
9 Clip, Hairpin (1) — 10 Screw, 1/4-20 x 1/2” Oval Head Flange (9) — 11 Screw, #10-24 x 1/4” Oval Head Blade (13) — 12 Screw, #10-24 x 1” Lower Housing (4) — 13 Screw, #10-24 x 5/16” Pan Head (4)
14 Wiring Harness 763413 763413
15 Ceiling Canopy 763400-BS 763400-BS
16 Coupler Cover 763401-BS 763401-BS
17 Lower Housing 763409-MBX 763409-MAB
18 Blade Assembly (4 per set) 763405-MBX 763405-MAB
19 Flange Assembly (4 per set) 763402-BS 763402-BS
20 Light Kit Assembly 763410 763410
21 Glass 763414 763414
22 SW114 Wall Control 763497 763497
23 SW105 Receiver 762401 762401
24 50-Watt MR-16, GU-10 Halogen Bulb 763494 763494
Owner's Manual BP7353 BP7353
Before discarding packaging material, be certain all parts have been removed.
HOW TO ORDER REPAIR PARTS
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION:
The model number of your Fan will be found on a label attached to the top housing.
For repair parts, phone 1-800-654-3545.
• PART DESCRIPTION
• MODEL NUMBER
• PART NUMBER
• NAME OF ITEM