Emerson CF955-3 User Manual

READ AND SAVE THESE INSTRUCTIONS
Model No.
CF955BS 03 CF955ORB 03 CF955WW 03
Part No. F40BP73730003 Form No. BP7373-3
ETL Model No.: CF955-3
MIDWAY ECO
54” Ceiling Fan
Owner's Manual
LIMITED WARRANTY
What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered.
What The Period Of Coverage Is:
As it applies to the motor, this warranty will last for thirty years from the date you purchased your ceiling fan. Repair and replacement of defective parts on the light fixture housing or electronics (excluding the lamp) for two years from the date of purchase. All other components and accessories are covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.
What Will Emerson Electric Co. Do To Correct Problems:
Emerson will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no charge to you. If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson will refund the actual purchase price of your fan.
WE WILL SHIP THE REPAIRED PRODUCT OR REPLACEMENT TO YOU AT NO CHARGE, BUT YOU ARE RESPONSIBLE FOR ALL COSTS OF REMOVAL, REINSTALLATION AND SHIPPING OF THE PRODUCT TO EMERSON.
How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division of Emerson Electric Co., 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product with your request.
• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center. You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage.
What Is Not Covered:
The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does not cover any defects, malfunctions or failures caused by:
• Repairs by persons not authorized by Emerson Electric Co.,
• Use of parts or accessories not authorized by Emerson Electric Co.,
• Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or
• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.
Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:
• The original purchaser or user ceases to own the product, or
• The fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no employee, agent, dealer or other person is authorized to give any warranties on behalf of Emerson Electric Co..
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to such damages as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if this product does not work properly.
How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
ENERGY STAR
2
WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. AVERTISSEMENT : suivez ces instructions pour ne pas risquer de causer un incendie, un choc électrique ou
des blessures graves.
Safety Instructions
1. Read your owner’s manual carefully and keep it for future reference.
2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.
3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.
4. Do not put anything into the fan blades while they are turning.
5. Do not operate reversing switch until fan blades have come to a complete stop.
Additional Safety Instructions for Installation
1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.
2. All wiring must be in accordance with the National Electrical Code “ANSI/NFPA 70-2008” and Local Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.
3. The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support”, and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
4. The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling.
5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.
6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.
NOTE: This fan is suitable for use with solid-state speed controls. WARNING: To reduce the risk of fire or electrical shock, this fan should only be used with fan speed control,
Model No. FR-7861LMA, manufactured by Rhine Electric Co., Ltd. AVERTISSEMENT: pour réduire le risque d'incendie ou de choc électrique, ce ventilateur ne doit être utilisé
qu'avec la commande de réglage de la vitesse du ventilateur Modèle N° FR-7861LMA, fabriquée par Rhine Electric Co., Ltd.
WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson could result in personal injury or property damage.
AVERTISSEMENT: ce produit est conçu pour un emploi exclusif avec les pièces fournies avec ce produit et/ou avec des accessoires désignés spécifiquement pour emploi avec ce produit par Emerson Electric Co. La substitution de pièces ou d'accessoires n'ayant pas été désignés pour emploi avec ce produit par Emerson pourrait causer des blessures ou des dommages matériels.
WARNING: To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
AVERTISSEMENT: pour réduire le risque de blessures, ne courbez pas la collerette de pale lors de l'installation, ou lorsque vous équilibrez les pales ou nettoyez le ventilateur. N'insérez pas d'objets étrangers entre les pales du ventilateur en mouvement.
WARNING: To reduce the risk of electrical shock, this fan must be installed with a general use, isolating control/switch.
AVERTISSEMENT: pour réduire le risque de choc électrique, il faut installer ce ventilateur avec un interrupteur/coupe-circuit isolant universel.
WARNING/AVERTISSEMENT
!
DATE CODE:
The date code of this fan may be found on the box, stamped in ink on a white label. You should
record this data above and keep it in a safe place for future use.
ETL Model No.: CF955-3
3
EMERSON QUICK START GUIDE
The Quick Start Guide covers the installation instructions common for ceiling fan operations. If additional assistance with wiring, alternate hanging systems, or lighting options, proceed to the complete instructions of this Owner’s Manual.
The Quick Start Guide sections include page numbers to correspond with the appropriate sections of the Owner’s Manual for detailed instructions.
* See Unpacking Instructions for a complete list of
parts for installation.
Installation of Downrod (page 76)
1. Remove the hanger ball from
the downrod.
2. Install the downrod to the
motor coupling using the clevis pin and hairpin clip.
3. Tighten the setscrews.
1. Disconnect electrical power to
the branch circuit at the circuit breaker or fuse box before attempting to install the ceiling fan hanger bracket on the outlet box.
2. The fan must be hung with at
least 7’ of clearance from floor to blades.
3. Attach the hanger bracket to
the outlet box.
4. Seat the hanger ball/downrod
assembly on the hanger bracket.
Hanging Your Ceiling Fan (page 10)
To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
!
WARNING
Installation of Blade Assembly (page 8)
1. Turn fan assembly upside
down in preparation for mounting fan blade assemblies.
2. To ensure proper blade
assembly, make sure the label on the blades are facing the bottom of the ceiling fan. Slide blade through center slot in fan housing. Mount blade to fan housing using three 3/16-24 x 1/2” slotted Phillips washer head blade screws.
Installation of Switch Housing (page 8)
1. Remove two of the four
screws in the motor assembly and loosen the remaining two screws.
2. Connect the terminals of the
lower housing assembly to the terminals of the fan motor assembly.
Installation of Ceiling Fan (page 8)
1. Remove the three screws pre-
installed on top of the fan assembly. Install the coupler cover and ceiling cover onto the downrod. Reinstall the three screws through the coupler cover.
2. Reinstall the hanger ball onto
the downrod, place the pin into the hanger ball and tighten the setscrew.
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse or circuit breaker box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
!
WARNING
ETL Model No.: CF955-3
CEILING
AT LEAST
7'
FLOOR
4
1. Pull the wire leads, coming from the end of the downrod, and
the supply wires through the open side of the hanger bracket.
2. Position the Receiver in the ceiling cover so that the flat side of
the receiver faces up and the open portion of the receiver is to the right, as shown.
3. Using wire connectors (supplied), make wiring connections as
follows:
a. Connect the green ground wires from the hanger bracket
and the hanger ball to the supply ground wire (bare or green).
b. Connect the white fan to the white supply wire.
c. Connect the black fan wire to the black supply wire.
Wiring Ceiling Fan (page 11)
1. The receiver must be programmed within 2 minutes of restoring
electricity to the fan. Program the receiver code by pushing and holding down the remote control OFF button for 3-5 seconds. The ceiling fan lights will blink when the receiver has completed programming.
2. If programming fails, shut off and turn on the electricity at the
wall switch to reset the receiver. Repeat Step 1 above.
3. If programming continues to fail, change the remote code and
repeat Steps 1 and 2 as necessary until the fan successfully completes the programming procedure.
NOTE: Fan installation must be completed, including the installation of the fan blades, before testing the remote control.
4. Your SR600 Fan/Light remote control has full control of your
fan speed, air flow direction and light intensity.
NOTE: The following procedure must be completed.
5. Operate the fan at high speed for 2 minutes. Reverse the fan
and operate on high speed 2 additional minutes.
1. After connections have been made, turn leads upward and
carefully push leads into the outlet box, with the white and green leads on one side of the outlet box and the black, blue and yellow leads on the other side of the outlet box.
2. Lift the ceiling cover up to the threaded studs and turn until
studs protrude through the holes in the ceiling cover.
3. Secure the ceiling cover in place by sliding lock-
washers over the threaded studs and installing the two knurled knobs (supplied). Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling. Your fan is now wired to be controlled using the remote control transmitter.
Installation of Ceiling Cover (page 12)
EMERSON QUICK START GUIDE
* For additional installation review full instructions on
page 13.
Programming, High Speed Conditioning and Operation of Remote Control (pages 13 and 14)
ETL Model No.: CF955-3
SUPPLY GROUND WIRE
LISTED WIRE CONNECTOR (3)
GREEN WIRE (GROUND) FROM HANGER BRACKET
GREEN WIRE (GROUND) FROM HANGER BALL
THREADED STUD
KNURLED KNOB
BLACK FAN WIRE
NOTE: CEILING COVER OMITTED FOR CLARITY.
WHITE SUPPLY (NEUTRAL)
WHITE FAN WIRE
BLACK SUPPLY (HOT)
THREADED STUD (2)
CEILING COVER
LOCKWASHERS (2)
5
Before assembly your ceiling fan, refer to section on proper method of wiring your fan (page 11). If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.
WARNING
!
Avant d'effectuer le montage de votre ventilateur de plafond, référez-vous à la section consacrée à la méthode de câblage appropriée pour votre ventilateur (page 8). Si vous pensez que vous n'avez pas assez de connaissances ou d'expérience en matière de connexions électriques, demandez à un électricien professionnel d'installer votre ventilateur.
AVERTISSEMENT
!
ETL Model No.: CF955-3
Unpacking Instructions
This Manual Is Designed to Make it as Easy as Possible for You to Assemble,
Install, Operate and Maintain Your Ceiling Fan
Tools Needed for Assembly
One Phillips head screwdriver One stepladder One 1/4” blade screwdriver One wire stripper…
MATERIALS
Wiring outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of the following size:
Installed Wire Length Wire Size A.W.G.
Up to 50 ft. 14
50-100 ft. 12
1. Check to see that you have received the following
parts:
NOTE: If you are uncertain of part description, refer to exploded view illustration.
a. Fan motor assembly b. One lower housing assembly c. One ceiling cover d. Five fan blades e. One hanger ball/downrod assembly f. One hanger bracket g. One glass globe h. One fan/light remote control (transmitter) i. One coupler cover j. Four 13-watt GU-24 fluorescent lamps k. One loose parts bag containing:
1. Sixteen 3/16-24 x 1/2” slotted Phillips washer head blade screws
2. Three wire connectors
3. Two 1-1/4" threaded studs
4. Two lockwashers
5. Two knurled knobs
6. One clevis pin
7. One hairpin clip
8. One 1.25A 125V fuse (spare)
9. One 5/32-32 x .375” pan head screw (spare)
10. One 5/32-32 x .75” slotted head screw (spare)
NOTE: Place the parts from the loose parts bags in a small container to keep them from being lost. If any parts are missing, contact your local retailer or catalog outlet for replacement before proceeding.
Ce produit est conçu pour un emploi exclusif avec les pièces fournies avec ce produit et/ou avec des accessoires désignés spécifiquement pour emploi avec ce produit par Emerson Electric Co. La substitution de pièces ou d'accessoires n'ayant pas été désignés pour emploi avec ce produit par Emerson Electric Co. pourrait causer des blessures ou des dommages matériels.
AVERTISSEMENT
!
Il ne faut pas installer ou utiliser ce ventilateur si l'un quelconque de ses éléments est endommagé ou manquant. Dans ce cas, appelez ce numéro gratuit :
1-800-654-3545
AVERTISSEMENT
!
Do not install or use fan if any part is damaged or missing. Call Toll-Free:
1-800-654-3545
This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
WARNING
!
WARNING
!
6
ETL Model No.: CF955-3
Unpacking (continued)
Your Emerson ceiling fan comes supplied with a Fan/Light Remote Control which consists of a receiver mounted inside the ceiling cover of the fan motor housing. This system allows you to regulate your ceiling fan speed and light ON/OFF.
2. Remove the fan assembly from the protective
plastic bag. Place the fan assembly into the upper foam pad with the top of the motor facing up.
The upper foam pad serves as a holder for the fan during the first stages of assembly.
i. COUPLER COVER
a. FAN ASSEMBLY
g. GLASS BOWL
f. HANGER BRACKET
e. HANGER BALL/ DOWNROD ASSEMBLY
c. CEILING COVER
j. 13W GU-24 FLOURESCENT LAMPS
b. LOWER HOUSING ASSEMBLY
k. LOOSE PARTS BAG
h. FAN/LIGHT CONTROL
d. FAN BLADES
Loading...