Emerson CF925BK00, CF925BS00, CF925OB00, CF925WW00 User Manual

Part No. F40BP72050004 Form No. BP7205-4
READ AND SAVE THESE INSTRUCTIONS
Model No.
CF925BK00 CF925BS00 CF925WW00 CF925OB00
COOLER
Net Weight: 26.8 Lbs.
Ceiling Fan
Owner's Manual
LIMITED WARRANTY
What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered.
What The Period Of Coverage Is:
As it applies to the motor, this warranty will last for thirty years from the date you purchased your ceiling fan. All other components and accessories are covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.
What Will Emerson Company Do To Correct Problems:
Emerson Company will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no charge to you. If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson Company will refund the actual purchase price of your fan. We will ship the repaired product or replacement to you at no charge, but you are responsible for all costs or removal, reinstallation and shipping of the product to Emerson Company.
How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division of Emerson Company, 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product with your request.
• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center.
You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage.
What Is Not Covered:
The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does not cover any defects, malfunctions or failures caused by:
• Repairs by persons not authorized by Emerson Company,
• Use of parts or accessories not authorized by Emerson Company,
• Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or
• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.
Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:
• The original purchaser or user ceases to own the product, or
• The fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no employee, agent, dealer or other person is authorized to give any warranties on behalf of Emerson Company.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to such damages as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if this product does not work properly.
How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
2
WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.
Safety Instructions
1. Read your owner’s manual carefully and keep it for future reference.
2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.
3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.
4. Do not put anything into the fan blades while they are turning.
5. Do not operate reversing switch until fan blades have come to a complete stop.
Additional Safety Instructions for Installation
1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.
2. All wiring must satisfy National and Local Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.
3. The outlet box and joist must be securely mounted an capable of reliably supporting a least 50 pounds. Use only U.L. outlet boxes listed as acceptable for fan support, and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
4. The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling.
5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.
6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.
WARNING: To avoid fire, shock or injury, do not use an Emerson or any other brand of control not specifically approved for this fan.
WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use this product by Emerson Company could result in personal injury or property damage.
WARNING: To Reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
WARNING
!
DATE CODE:
The date code of this fan may be found on
the box, stamped in ink on a white label.
You should record this data above and keep
it in a safe place for future use.
1. Check to see that you have received the following parts:
NOTE: If you are uncertain of part description, refer to exploded view illustration.
a. Fan motor assembly b. One ceiling cover c. Five fan blades d. Five blade flanges e. One hanger ball/downrod assembly f. One hanger bracket g. One glass globe h. One SR100 fan/light control i. One light kit plate j. One adapter plate k. One coupler cover l. One loose parts bag containing:
1. Sixteen 3/16-24 x 5/16” slotted Phillips washer head blade screws
2. Sixteen Fiber blade washers
3. Eleven 1/4-20 x 3/8” Phillips oval head flange screws
4. Three wire connectors
5. Two 3/4" threaded studs
6. Two lockwashers
7. Two knurled knobs
8. One clevis pin
9. One hairpin clip
10. One 3/16” hex wrench
11. Three 3/16-24 nuts
This Manual Is Designed to Make it as Easy as Possible for You to
Assemble, Install, Operate and Maintain Your Ceiling Fan
Tools Needed for Assembly
One Phillips head screwdriver One stepladder One 1/4” blade screwdriver One wire stripper Three wire connectors (supplied) One 3/16” hex wrench (supplied)
MATERIALS
Wiring outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of the following size:
3
Unpacking Instructions
For your convenience, check-off boxes are provided next to each step. As each step is completed, place a check mark in the box. This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted.
NOTE: Place the parts from the loose parts bags in a small container to keep them from being lost. If any parts are missing, contact your local retailer or catalog outlet for replacement before proceeding.
2. Remove the fan assembly from the protective
plastic bag. Place the fan assembly into the upper foam pad with the top of the motor facing up.
The upper foam pad serves as a holder for the fan during the first stages of assembly.
Installed Wire Length Wire Size A.W.G.
Up to 50 ft. 14
50-100 ft. 12
Before assembly your ceiling fan, refer to section on proper method of wiring your fan (page 6). If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.
WARNING
!
Do not install or use fan if any part is damaged or missing. Call Toll-Free:
1-800-654-3545
This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Company. Substitution of parts or accessories not designated for use with this product by Emerson Company could result in personal injury or property damage.
WARNING
!
WARNING
!
COUPLER COVER
HANGER BRACKET
FAN ASSEMBLY
LIGHT KIT PLATE
ADAPTER PLATE
HI OFF
GLASS BOWL
HANGER BALL/ DOWNROD ASSEMBLY
CEILING COVER
LOOSE PARTS BAG
LOWMED
SR100 FAN/LIGHT CONTROL
BLADE FLANGES
FAN BLADES
1. Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 1). Remove the clevis pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in step 5.
2. Loosen setscrew in motor coupling if necessary. Separate, untwist and unkink the three 80” motor leads. Route the motor lead wires through the downrod. Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the clevis pin and secure with the hairpin clip (Figure
2). The clevis pin must go through the holes in the motor coupling and the holes in the downrod. Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull on the downrod to make sure the clevis pin is properly installed.
3. While pulling up on the downrod, securely tighten the setscrew in the motor coupling (Figure 3).
NOTE: The setscrew must be properly installed as described above, or fan wobble could result.
Figure 2
4. Make sure the grommet is properly installed in the coupling cover then slide the coupler cover on the downrod until it rests on the motor housing. Place the ceiling cover over the downrod. Be sure both the ceiling cover and the coupler cover are oriented correctly (Figure 3).
5. Reinstall the hanger ball (Figure 4) on the downrod as follows. Route the motor leads through the downrod. Position the pin through the two holes in the downrod and align the ball so the pin is captured in the groove in the top of the hanger ball. Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball. A loose setscrew could create fan wobble.
6. The fan comes with blue, black and white leads that are 80” long. Before installing fan, measure up approximately 6 to 9-inches above top of hanger ball/downrod assembly. Cut off excess leads and strip back insulation 1/2-inch from end of leads.
7. Mount blade flanges to fan blades using three 3/16-24 x 5/16” slotted Phillips washer head blade screws and three fiber blade washers (Figure 5).
Figure 4
4
Figure 3
Figure 1
How to Put Your Ceiling Fan Together
It is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed (as shown in Figure 2) could result in the fan falling.
WARNING
!
It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling.
WARNING
!
PIN
SETSCREW
DOWNROD
HANGER BALL
CEILING COVER
COUPLER COVER
MOTOR COUPLING
CLEVIS PIN
SETSCREW
HAIRPIN CLIP
CLEVIS PIN
HANGER BALL
PIN
DOWNROD
HAIRPIN CLIP
SETSCREW
CLEVIS PIN
MOTOR COUPLING
DOWNROD
SETSCREW
5
Electrical Requirements
If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.
Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.
The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.
8. Turn fan assembly upside down in preparation for mounting fan blade assemblies.
NOTE: Take care not to scratch fan housing when installing blades.
9.Attach blade assembly to motor hub using two 1/4-
20 x 3/8” Phillips oval head flange screws. Make sure the screws are tightened securely (Figure 6). Repeat this procedure for other four blade assemblies.
10.Using the 3/16” hex wrench (supplied), loosen the
setscrew in the adapter plate collar. Pass the blue and white leads through the collar and tightly screw the adapter plate onto the motor shaft (Figure 7). Securely tighten the setscrew in the adapter plate collar.
NOTE: The setscrew must be securely tightened to prevent the adapter plate from loosening when the glass bowl is installed.
Figure 6
Figure 7
11.Connect the white wire from the light kit plate to the white wire from the motor; connect the black wire from the light kit plate to the blue wire from the motor (Figure 7). Make sure the connectors are fully engaged.
12.Position the light kit plate so that the studs on the adapter plate protrude through the three holes in the light kit plate. Install a 3/16-24 nut on each stud.
NOTE: Be sure the wires are not pinched between the light kit plate and the spacers or motor shaft.
LIGHT KIT PLATE
3/16-24 NUT (3)
Figure 8
FIBER
Figure 5
To reduce the risk of personal injury, do not bend the blade flanges when installing the blades or cleaning the fan. Do not insert foreign objects between rotating fan blades.
WARNING
!
To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked acceptable for fan support, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
WARNING
!
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
WARNING
!
To avoid fire or shock, follow all wiring instructions carefully.
Any electrical work not described in these instructions should be done or approved by a licensed electrician.
WARNING
!
FAN BLADE
BLADE WASHER
BLADE FLANGE
3/16-24 x 5/16" SLOTTED PHILLIP WASHER HEAD BLADE SCREW (3)
MOTOR HUB
1/4-20 x 3/8" FLANGE SCREWS
FLANGE
CONNECTORS
LIGHT KIT PLATE
SETSCREW
SPACER
ADAPTER PLATE
If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician.
1. Your ceiling fan is supplied with an Emerson
SR100 Fan/Light Control. Wire your ceiling fan in accordance with the Owner’s Manual supplied with the SR100 Fan/Light Control. After splices have been made, carefully push splices up into the outlet box.
2. After completion of wiring, install the ceiling cover as follows. Screw the two 3/4” threaded studs (provided) into the tapped holes in the hanger bracket.
6
How to Wire Your Ceiling Fan
Figure 12
4. Secure the ceiling cover in place by sliding lockwashers over the threaded studs and installing the two knurled knobs (supplied). (Figure 12.) Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod. Your fan is now wired to be turned on and off from the fan switch.
1. Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box. (Figure 10.)
2.Carefully lift the fan and seat the hanger ball/downrod assembly on the hanger bracket that was just attached to the outlet box (Figure 11). Be sure the groove in the ball is lined up with tab on the hanger bracket (Figure 10).
How to Hang Your
Ceiling Fan
TWO SCREWS SUPPLIED WITH OUTLET BOX
HANGER BRACKET
TAB
OUTLET BOX
Figure 9
Figure 10
Figure 11
The fan must be hung with at least 7' of clearance from floor to blades (Figure 9).
WARNING
!
The outlet box must be securely anchored and capable of withstanding a load of at least 50 lbs.
WARNING
!
To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked acceptable for fan support, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician in in doubt.
WARNING
!
Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until bracket contacts box. If bracket and/or outlet box are not securely attached, the fan could wobble or fall.
WARNING
!
Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard.
WARNING
!
To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and hanger bracket.
WARNING
!
Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result.
WARNING
!
3. Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover (Figure 12).
To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling.
WARNING
!
CEILING
NOTE: CEILING COVER, SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY.
OUTLET BOX
HANGER BRACKET
HANGER BALL/ DOWNROD ASSEMBLY
AT LEAST
7'
FLOOR
CEILING COVER
3/4" THREADED STUD
KNURLED KNOB
LOCKWASHERS (2)
Trouble Shooting
TROUBLE PROBABLE CAUSE SUGGESTED REMEDY
1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers.
2. Loose power line connections to the fan, or loose 2. Check line wire connections to fan and switch wire switch wire connections in the switch housing. connections in the switch housing.
CAUTION: Make sure main power is turned off.
3. Reversing switch in neutral position. 3. Make sure reversing switch position is all the way to one
side.
2. Fan sounds noisy. 1. Blades not attached to fan. 1. Attach blades to fan before operating.
2. Screws securing fan blade flanges to motor are 2. Check to make sure the screws which attach the fan loose. flanges to the motor are tight.
3. Screws holding blades to flanges are loose. 3. Tighten screws securely.
4. Glass bowl loose. 4. Tighten the glass bowl securely.
3. Fan wobbles 1. Setscrew in motor coupling is loose. 1. Raise coupler cover and tighten the setscrew securely. excessively. 2. Setscrew in hanger ball/downrod assembly is 2. Tighten the setscrew in the hanger ball/downrod assembly.
loose.
3. Screws securing fan blade flanges to motor are 3. Check to be sure screws which attach the fan blade loose. flanges to the motor are tight.
4. Fan blade flanges not seated properly. 4. Check to be sure the fan blade flanges seat firmly and
uniformly to the surface of the motor. If flanges are seated incorrectly, loosen the flange screws and retighten according to the procedure in the section on "How to Put Your Ceiling Fan Together".
5. Hanger bracket and/or ceiling outlet box is not 5. Tighten the hanger bracket screws to the outlet box, and/or securely fastened. secure outlet box.
6. Fan blades out of balance. 6. Interchanging an adjacent (side-by-side) blade pair can
redistribute the weight and result in smoother operation.
1. Restore electrical power to the outlet box by turning the electricity on at the main fuse box or circuit breaker panel.
2. All fans are shipped from the factory with the reversing switch positioned to circulate air downward. If airflow is desired in opposite direction, turn your fan off and wait for the blades to stop
turning, then slide the reversing switch to (located at the top of the motor housing) opposite position, and turn fan on again. The fan blades will turn in the opposite direction and reverse the airflow.
3. Refer to the Owner’s Manual supplied with the SR100 Fan/Light Control for operation of the fan and light.
7
Using Your Ceiling Fan
Installing Glass Globe
WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER
BEFORE TROUBLE SHOOTING YOUR FAN.
1. Install three candelabra base bulbs in sockets.
2. Place the glass bowl into the opening in the light kit
plate, aligning the three flat areas on the top edge of the glass with the three raised dimples on the light kit plate and turn the glass bowl clockwise until it stops (Figure 13).
NOTE: periodically check that the glass bowl is seated fully clockwise in the light kit plate.
Figure 13
RAISED DIMPLES
LIGHT KIT PLATE
FLAT AREA
9
19
6
1
2
3
4
8
20
7
5
14
12
10
13
22
21
HI OFF
LOWMED
22
11
15
16
17
18
23
Key Model No.
No. Description CF925WW 00 CF925BK 00 CF925BS 00 CF925OB 00
— Hanger Ball Assembly, 761655 761655-1 761655-17 761655-9
Consisting of: 1 Hanger Bracket — 2 Hanger Ball — 3 Downrod
— Parts Bag Containing: 761729 761729-1 761729-2 761729-1
4 Wire Connector (3) — 5 Stud, Threaded, 3/4" (2) — 6 Lockwashers (2) — 7 Knob, Knurled (2) — 8 Pin, Clevis — 9 Clip, Hairpin
11 Hex Wrench, 3/16” — 13 Nut, 3/16-24 (3) — 15 Screw, 1/4-20 x 3/8” (11) — 16 Screw, 3/16-24 x 5/16” (16) — 23 Fiber Blade Washer (16)
10 Adapter Plate 761696 761696-1 761696-2 761696-3 12 Light Kit Plate Assembly 761732 761732 761732 761732 14 Glass Globe 761670 761670 761670 761670 17 Blade (set of 5) 761727-1 761727 761727-2 761727-3 18 Flange (set of 5) 761728 761728-1 761728-2 761728-3 19 Canopy, Ceiling 761504-3 761504-9 761504-12 761504-11 20 Wiring Harness with Capacitor 761730 761730 761730 761730 21 Coupler Cover 761760 761760-1 761760-2 761760-3 22 SR100 Fan/Light Control
****
Owner's Manual BP7205-4 BP7205-4 BP7205-4 BP7205-4
* Contact your nearest authorized Emerson fan dealer for replacement SR100 Fan/Light Control.
Before discarding packaging material, be certain all parts
have been removed.
HOW TO ORDER REPAIR PARTS
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE
FOLLOWING INFORMATION:
• PART NUMBER
• PART DESCRIPTION
• NAME OF ITEM
• MODEL NUMBER
The model number of your Fan will be found on a label attached to
the top housing.
For repair parts, phone 1-800-654-3545.
EMERSON
Air Comfort Products
DIVISION OF EMERSON COMPANY
8100 W. Florissant, St. Louis, MO 63136
Part No. F40BP72050004 Printed in Taiwan 09/99 Form No. BP7205-4
Repair Parts Listing
IMPORTANT CARE INSTRUCTIONS
for your Ceiling Fan
Periodic cleaning of your new ceiling fan is the only maintenance that is needed.
When cleaning, use only a soft brush or lint free cloth to avoid scratching the finish.
Abrasive cleaning agents are not required and should be avoided to prevent damage to finish.
Maintenance
Accessories
1. Downrod Extension Kits (see store or catalog).
Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock.
WARNING
!
This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Company. Substitution of parts or accessories not designated for use with this product by Emerson Company could result in personal injury or property damage.
The use of any other control not specifically approved for this fan could result in fire, shock and personal injury.
WARNING
!
WARNING
!