Safety Instructions
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a. Use this unit only in a manner intended by the
manufacturer. If you have questions, contact the manufacturer.
b. Before servicing or cleaning unit, switch power off
at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.
WARNING
!
Additional Safety Instructions for Installation
1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.
2. All wiring must be in accordance with the National Electrical Code “ANSI/NFPA 70-2014” and Local Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.
3. The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support of 22.7kg. (50 lbs.) or less”, and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
4. The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling.
5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.
6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.
WARNING: To reduce the risk of electrical shock, this fan must be installed with an isolating wall control/switch.
NOTE: This fan is suitable for use with solid-state speed controls.
WARNING: To reduce the risk of fire or electrical shock, this fan should only be used with fan speed control, Model No. FR-7861LMG-02, manufactured by Rhine Electric Co., Ltd.
WARNING: To avoid fire, shock or injury, do not use an Emerson or any other brand of control not specifically approved for this fan.
WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson could result in personal injury or property damage.
WARNING: To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
NOTE: All setscrews must be checked and re-tightened where necessary before installation.
1. Read your owner’s manual carefully and keep it for future reference.
2. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.
3. Do not put anything into the fan blades while they are turning.
4. Do not operate reversing switch until fan blades have come to a complete stop.
DATE CODE:
The date code of this fan may be found on the box, stamped in ink on a white label. You should record
this data above and keep it in a safe place for future use.
ETL Model No.: CF921
READ AND SAVE THESE INSTRUCTIONS
Table of Contents
Section Page
Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1. Unpacking Instructions . . . . . . . . . . . . . . . . . . . . . . . . .3-4
2. Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . .4
3. Ceiling Fan Assembly . . . . . . . . . . . . . . . . . . . . . . . . . .5-7
4. How to Hang Your Ceiling Fan . . . . . . . . . . . . . . . . . . .7-8
5. How to Wire Your Ceiling Fan . . . . . . . . . . . . . . . . . . . .8-9
6. Remote Control Procedures . . . . . . . . . . . . . . . . . . . .9-10
7. Programming the Receiver Operating Frequency
& High Speed Conditioning of Fan Control . . . . . . . .11
Section Page
8. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
9. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
10. Optional Accent Kit Installation . . . . . . . . . . . . . . . . . . .12
11. Trouble Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
12. Repair Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14-15
Ceiling Fan Limited Warranty . . . . . . . . . . . . . . . . . . . . . . .19
1. Unpacking Instructions
3
emersonfans.com
Please contact 1-800-654-3545 for further assistance
ETL Model No.: CF921
This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
WARNING
!
Do not install or use fan if any part is damaged or missing. Call Toll-Free:
1-800-654-3545
WARNING
!
1. Check to see that you have received the following
parts:
NOTE: If you are uncertain of part description, refer to exploded view illustration.
NOTE: Place the parts from the loose parts bags in a small container to keep them from being lost. If any parts are missing, contact your local retailer or catalog outlet for replacement before proceeding.
2. Remove the fan assembly from the protective
plastic bag. Place the fan assembly into the upper foam pad with the top of the motor facing up.
The upper foam pad serves as a holder for the fan during the first stages of assembly.
PACKAGE CONTENTS
HARDWARE CONTENTS
Part Description Quantity
1 Threaded Studs, #8-32 x 1-1/4” 2
2 Knurled Knobs, #8-32 2
3 Lockwashers, External Tooth #8 2
4 Wire Connectors 3
5 Clevis Pin 1
6 Hairpin Clip 1
7 #10-24 x 12mm Washer Head
Blade Screws 21
8 16mm Flat Washers (OD) 21
9 #8-32 x 8mm Flat Head Screw (spare) 1
10 #8-32 x 8mm Pan Head Screw (spare) 1
11 1/4-20 x 14 Captive Screw with
Lockwasher (spare) 1
12 Blade Balance Kit 1
Part Description Quantity
A Fan Motor Assembly 1
B Ceiling Canopy 1
C Motor Coupling Cover 1
D Fan Blades Flanges 5
E Hanger Bracket 1
F Hanger Ball/Downrod Assembly 1
G Switch Housing Assembly 1
H Remote Control 1
1
4
2
5
6
A
B
C
D
3
7
E
F
G
H
12981011
Before assembling your ceiling fan, refer to section on proper method of wiring your fan (page 8). If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.
WARNING
!
Tools Needed for Assembly
One Phillips head screwdriver One stepladder One 1/4” blade screwdriver One wire stripper
Materials
Wiring outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of following size:
Installed Wire Length Wire Size A.W.G.
Up to 50 ft. 14
50-100 ft. 12
Your Emerson ceiling fan comes supplied with a Fan/Light Remote Control which consists of a receiver mounted inside the ceiling cover of the fan motor housing. This system allows you to regulate your ceiling fan speed and light ON/OFF.
4
ETL Model No.: CF921
This Manual Is Designed to Make it as Easy as Possible for You to Assemble,
Install, Operate and Maintain Your Ceiling Fan
2. Electrical Requirements
Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.
The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.
To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support of 22.7 kg. (50 lbs.) or less”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
WARNING
!
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
WARNING
!
To avoid fire or shock, follow all wiring instructions carefully.
Any electrical work not described in these instructions should be done or approved by a licensed electrician.
WARNING
!
If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.
IMPORTANT: Your ceiling fan will not function properly, and may be damaged, if used with any wall dimmer switch or control other than the Emerson Electric Fan/Light Remote Control supplied with the fan.
1. Unpacking Instructions (continued)
emersonfans.com
Please contact 1-800-654-3545 for further assistance
ETL Model No.: CF921
3. Ceiling Fan Assembly
5
Figure 2
Figure 1
1. Remove the hanger ball by loosening the setscrew in
the hanger ball until the ball falls freely down the downrod (Figure 1). Remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in Step 4.
2. Separate, untwist and unkink the two 80” motor
leads. Route the motor lead wires through the downrod. Remove the upper setscrew from the motor coupling. Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the clevis pin and secure with the hairpin clip (Figure 2). The clevis pin must go through the holes in the motor coupling and the holes in the downrod. Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull on the downrod to make sure the clevis pin is properly installed. Reinstall the upper setscrew in the motor coupling. Check that the lower setscrew is tightened securely (Figure 2).
NOTE: The setscrews must be properly installed as described above, or fan wobble could result.
NOTE: If LKU100 is being assembled, see Page 12, “Optional Accent Light Kit Installation” of instruction procedures.
It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened. Failure to verify that the pin and setscrews are properly installed could result in the fan falling.
WARNING
!
HANGER BALL
SETSCREW
SETSCREW
CLEVIS PIN
CLEVIS PIN
UPPER SETSCREW
MOTOR COUPLING
HAIRPIN CLIP
PIN
DOWNROD
DOWNROD
CLEVIS PIN
HAIRPIN CLIP
6
ETL Model No.: CF921
It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling.
WARNING
!
3. Ceiling Fan Assembly (continued)
3. Make sure the grommet is properly installed in the
coupling cover, then slide the coupling cover on the downrod until it rests on the motor housing. Place the ceiling cover over the downrod. Be sure that the ceiling cover and the coupling cover are both oriented correctly (Figure 3).
4. Reinstall the hanger ball (Figure 3) on the downrod
as follows. Route the two 80” motor leads through the hanger ball. Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball. Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball. A loose setscrew could create fan wobble.
5. The fan comes with black and white leads that are
80” long. Before installing fan, measure up approximately 6 to 9-inches above top of hanger ball/downrod assembly. Cut off excess leads and strip back insulation 1/2-inch from end of leads.
6. Carefully turn the partially assembled ceiling fan over
and set it on the shipping styrofoam for blade installation.
7. Remove the shipping spacers and the spacer
attachment screws from the motor before installation of blade assemblies. Discard the spacers and spacer screws (Figure 4).
8. Mount blade flanges to fan blades (sold separately)
using four #10-24 x 12mm washer head blade screws and four 16mm flat washers (Figure 5).
NOTE: Some accessory blades available are supplied with shorter screws. These shorter screws MUST be used to assemble the blades to flanges.
NOTE: Take care not to scratch fan housing when installing blades.
NOTE: Remove and discard the four shipping spacers and screws from the motor hub.
9. Loosely attach one blade assembly to the motor hub
using the two 1/4-20 x 14 captive screws with lockwashers. Make sure the screws are NOT tightened. (Figure 6.) Repeat this procedure for other four blade assemblies.
Figure 6
Figure 5
Figure 4
Figure 3
DOWNROD PIN
HANGER BALL
CEILING COVER
SWITCH HOUSING MOUNTING PLATE SCREW (4)
#10-24 x 12mm WASHER HEAD BLADE SCREW (4)
FAN BLADE
SWITCH HOUSING MOUNTING PLATE HOLE
BLADE FLANGE ASSEMBLY
SETSCREW
COUPLING COVER
SHIPPING SPACERS AND SCREWS
FLAT WASHER 16 mm OD (4 per blade/flange)
BLADE FLANGE
CAPTIVE SCREW
LOCKWASHER