Safety Instructions
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a. Use this unit only in a manner intended by the
manufacturer. If you have questions, contact the manufacturer.
b. Before servicing or cleaning unit, switch power off
at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.
WARNING
!
Additional Safety Instructions for Installation
1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.
2. All wiring must be in accordance with the National Electrical Code “ANSI/NFPA 70-2011” and Local Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.
3. The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support of 15.9kg. (35 lbs.) or less”, and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
4. The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling.
5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.
6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.
WARNING: To reduce the risk of electrical shock, this fan must be installed with an isolating wall control/switch.
NOTE: This fan is suitable for use with solid-state speed controls.
WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson could result in personal injury or property damage.
WARNING: To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
WARNING: To reduce the risk of electrical shock, this fan must be installed with a general use, isolating control/switch.
NOTE: All setscrews must be checked and re-tightened where necessary before installation.
1. Read your owner’s manual carefully and keep it for future reference.
2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.
3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.
4. Do not put anything into the fan blades while they are turning.
5. Do not operate reversing switch until fan blades have come to a complete stop.
DATE CODE:
The date code of this fan may be found on the box, stamped in ink on a white label. You should record
this data above and keep it in a safe place for future use.
U.L. Model No.: CF772
READ AND SAVE THESE INSTRUCTIONS
Unpacking Instructions
3
emersonfans.com
Please contact 1-800-654-3545 for further assistance
U.L. Model No.: CF772
This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
WARNING
!
Do not install or use fan if any part is damaged or missing. Call Toll-Free:
1-800-654-3545
WARNING
!
1. Check to see that you have received the following
parts:
NOTE: If you are uncertain of part description, refer to exploded view illustration.
NOTE: Place the parts from the loose parts bags in a small container to keep them from being lost. If any parts are missing, contact your local retailer or catalog outlet for replacement before proceeding.
2. Remove the fan assembly from the protective
plastic bag. Place the fan assembly into the upper foam pad with the top of the motor facing up.
The upper foam pad serves as a holder for the fan during the first stages of assembly.
PACKAGE CONTENTS
Part Description Quantity
A Fan Motor Assembly 1
B Ceiling Canopy 1
C Coupler Cover 1
D Blade Flanges 5
E Fan Blades 5
F Hanger Bracket 1
G Hanger Ball/Downrod Assembly 1
H Switch Housing Assembly 1
I Switch Housing Cover Plate 1
HARDWARE CONTENTS
Part Description Quantity
1 Threaded Studs, #8-32 x 1-1/4” 2 2 Knurled Knobs, #8-32 2 3 Lockwashers, #8 2 4 Wire Connectors, E3 3 5 Clevis Pin 1 6 Hairpin Clip 1 7 #10-32 x .25” Slotted Phillips
Washer Head Blade Screws 16
8 1/4-20 x .5” Round Head
Flange Screw (Spare) 1
9 12” Pull Chain w/Wood Ball 2
10 Blade Balance Kit 1
A
B
C
D
E
F
G
H
I
1
4
7
2
8
3
5
6
9
10
Before assembly your ceiling fan, refer to section on proper method of wiring your fan (page 9). If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.
WARNING
!
This Manual Is Designed to Make it as Easy as Possible for You to Assemble,
Install, Operate and Maintain Your Ceiling Fan
Tools Needed for Assembly
One Phillips head screwdriver One stepladder One 1/4” blade screwdriver One wire stripper One 5/16” open end wrench, or pliers Three wire connectors (supplied).
Materials
Wiring outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of following size:
Installed Wire Length
Wire Size A.W.G.
Up to 50 ft. 14
50-100 ft. 12
Ceiling Fan Assembly
4
U.L. Model No.: CF772
1. Remove the hanger ball by loosening the setscrew in
the hanger ball until the ball falls freely down the downrod (Figure 1). Remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in step 4.
2. Separate, untwist and unkink the three 80” motor
leads. Route the motor lead wires through the downrod. Align the clevis pin holes in the downrod with the holes in the motor coupler. Install the clevis pin and secure with the hairpin clip (Figure 2). The clevis pin must go through the holes in the motor coupler and the holes in the downrod. Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull on the downrod to make sure the clevis pin is properly installed.
3. While pulling up on the downrod, securely tighten the
two setscrews in the motor coupler.
Figure 1
Figure 2
It is critical that the clevis pin in the motor coupler is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed (as shown in Figure 2) could result in the fan falling.
WARNING
!
PIN
DOWNROD
DOWNROD
HAIRPIN CLIP
SETSCREW
HANGER BALL
SETSCREW
CLEVIS PIN
JAM NUT
MOTOR COUPLING
CLEVIS PIN
SETSCREW
MOTOR COUPLING
HAIRPIN CLIP
5
emersonfans.com
Please contact 1-800-654-3545 for further assistance
U.L. Model No.: CF772
Figure 3
Figure 4
Figure 5
Figure 6
4. Make sure the grommet is properly installed in the coupler cover, then slide the coupler cover on the downrod until it rests on the motor housing. Place the ceiling cover over the downrod. Be sure that the ceiling cover and the coupler cover are both oriented correctly (Figure 3).
5. Reinstall the hanger ball (Figure 4) on the downrod as follows. Route the three 80” motor leads through the hanger ball. Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball. Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball. A loose setscrew could create fan wobble.
6. The fan comes with blue, black and white leads that are 80-inches long. Before installing the fan, measure up approximately 6 to 9-inches above top of hanger ball/downrod assembly. Cut off excess leads and strip back insulation 1/2-inch from end of leads.
7. Mount blade flange to fan blade using three #10-32 x .25” slotted Phillips washers head screws (Figure 5).
8. Repeat this procedure for the remaining four blades and flanges.
9. Turn the fan assembly upside down in preparation for mounting the fan blade assemblies.
NOTE: Take care not to scratch fan housing when installing blades.
10. Carefully unscrew each shipping retainers from the
motor housing. Discard the five screws and shipping retainers (Figure 6).
11. Attach the blade assembly to the motor hub using
the two 1/4-20 x .5” round head flange screws preassembled in flange. Make sure the screws are tightened securely (Figure 6).
12. Repeat this procedure for the other four blade
assemblies.
It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling.
WARNING
!
To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
WARNING
!
GROMMET
PIN
HANGER BALL
CEILING COVER
DOWNROD
COUPLING COVER
DOWNROD
CEILING COVER
#10-32 x .25" SLOTTED PHILLIPS WASHER HEAD BLADE SCREW (3)
BLADE FLANGE
FAN BLADE
REMOVE SHIPPING RETAINER AND
SWITCH HOUSING PLATE
BLADE FLANGE
SCREW (5)
PREASSEMBLED 1/4-20 x .5" ROUND HEAD FLANGE SCREWS (2)