Emerson CF680WB00, CF680BQ00, CF680ORB00 User Manual

LIMITED WARRANTY
What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered.
What The Period Of Coverage Is:
As it applies to the motor, this warranty will last for ten years from the date you purchased your ceiling fan. All other components and accessories are covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.
What W
ill Emerson Electric Co. Do To Correct Problems:
Emerson Electric Co. will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no charge to you. If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson will refund the actual purchase price of your fan. We will ship the repaired product or replacement to you at no charge, but you are responsible for all costs or removal, reinstallation and shipping of the product to Emerson Electric Co.
How Can Y
ou Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division of Emerson Co., 8100 W. Florissant Ave., St. Louis, MO63136. Include all model numbers shown on the product with your request.
• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center.
You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage.
What Is Not Cover
ed:
The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does not cover any defects, malfunctions or failures caused by:
• Repairs by persons not authorized by Emerson Electric Co.,
• Use of parts or accessories not authorized by Emerson Electric Co.,
• Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or
• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.
Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:
• The original purchaser or user ceases to own the product, or
• The fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no employee, agent, dealer or other person is authorized to give any warranties on behalf of Emerson Electric Co.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to such damages as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if this product does not work properly.
How State Law Relates T
o The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Part No. F40BP73050001 Form No. BP7305-1
U.L. Model No.: CF680
READ AND SAVE THESE INSTRUCTIONS
WESTFIELD
Net Weight: 24.7 Lbs.
Wet Location
52” Ceiling Fan
Owner's Manual
CF680BQ00 CF680ORB00
Model No.
CF680WB00
BP7305 Westfield 6/30/06 12:10 AM Page 1
2
WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.
Safety Instructions
1. Read your owner’s manual carefully and keep it for future reference.
2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.
3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.
4. Do not put anything into the fan blades while they are turning.
5. Do not operate reversing switch until fan blades have come to a complete stop.
Additional Safety Instructions for Installation
1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.
2. The installation is to be in accordance with the National Electrical Code, ANSI/NFPA70-1999 and Local Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.
3. The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support”, and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
4. The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling.
5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.
6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.
NOTE: This fan is suitable for use with solid-state speed controls. WARNING: This product is designed to use only those parts supplied with this
product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
WARNING: To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
!
WARNING
DATE CODE:
The date code of this fan may be found on the box, stamped in ink on a white label. You should record this data above and keep it in a safe place for future use.
BP7305 Westfield 6/30/06 12:10 AM Page 2
3
THIS FAN IS SUITABLE FOR DAMP LOCATIONS SUCH AS
COVERED PORCHES, COVERED PATIOS, AND COVERED DECKS...
ANYWHERE THERE IS A ROOF OVERHEAD.
This Manual is Designed to Make it as Easy as Possible for You to
Assemble, Install, Operate and Maintain Your Ceiling Fan
Do not install or use fan if any part is damaged or missing. Call Toll-Free:
1-800-654-3545
!
WARNING
This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
!
WARNING
Tools Needed for Assembly
One Phillips head screwdriver One wire stripper One stepladder Five wire connector (supplied) Four 7-watt (max.) candelabra bulbs
Materials
Wiring, outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of the following sizes:
Installed Wire Length Wire Size A.W.G.
Up to 50 ft. 14 50-100 ft. 12
Before assembling your ceiling fan, refer to section on proper method of wiring your fan (page 10). If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.
!
WARNING
Unpacking Instructions
For your convenience, check-off boxes are provided next to each step. As each step is completed, place a check mark in the box. This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted.
NOTE: If you are uncertain of part description, refer to exploded view illustration.
a. Fan motor and housing assembly b. One upper housing c. One ceiling cover d. Four blade flanges e. Four fan blades f. One upper housing cover g. One center glass h. One hanger bracket i. One hanger ball/downrod assembly j. One switch cup assembly k. One switch cup adapter
1. Open styrofoam unit containing fan. Remove top half of styrofoam unit. Remove parts and check to see that you have received the following parts:
BP7305 Westfield 6/30/06 12:10 AM Page 3
4
l. One loose parts bag containing:
1. Two 8-32 x 1-1/4” threaded studs
2. Two knurled knobs
3. Two lockwashers
4. Five wire connectors
5. One clevis pin/hairpin clip assembly
6. Eleven 1/4-20 x 1/2” oval head screws
7. Sixteen 10-32 x .30” pan head screws
8. Sixteen #10 flat washers
9. Four 8-32 x 1/4” pan head screws
10. One pendant (large)
11. One pendant (small)
12. Two chain couplings
NOTE: Place the parts from the loose parts bags in a small container to keep them from being lost.
2. Remove the fan motor and housing
assembly from the protective plastic bag. Place the fan assembly into the lower foam pad with the bottom of the motor facing up.
The lower foam pad serves as a holder for the fan during the first stages of assembly.
Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.
The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.
To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
!
WARNING
If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse or circuit breaker box at this time and remove the existing light fixture.
Electrical Requirements
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse or circuit breaker box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
!
WARNING
BP7305 Westfield 6/30/06 12:10 AM Page 4
A
G
J
B
C
D
F
E
H
I
K
L
5
IMPORTANT: The side of the fan blade having the rib line MUST be facing upward as shown in Figure 1.
1. Mount the fan blades to the blade
flanges using three 10-32 x .30” pan head screws and three flat washers (screws and washers supplied) (Figure 1).
How to Assemble Your
Ceiling Fan
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse or circuit breaker box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
!
WARNING
To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
!
WARNING
Figure 1
2. Remove and discard the four shipping retainers securing the motor hub in the motor housing.
NOTE: Take care not to scratch the fan housing when installing the blade assemblies.
3. Insert an 1/4-20 x 1/2” oval head screw
(supplied) into each of the two recessed holes in one of the blade flanges.
4. Position the blade flange on the motor hub so that the screws in the blades flange align with two threaded holes in the motor hub (Figure 2). Loosely tighten the screws at this time. Repeat this procedure for the remaining four blade assemblies.
5. Gently snug all flange screws to the motor hub, working around the hub in a clockwise sequence. Next, securely tighten all flange screws, again working in a clockwise sequence. Failure to follow this procedure could result in fan wobble. This completes the blade installation.
Figure 2
!
WARNING
To reduce the risk of personal injury, do not bend the blade flanges when installing the flanges, balancing the blades or cleaning the fan. Do not insert foreign objects between rotating fan blades.
BP7305 Westfield 6/30/06 12:10 AM Page 5
RIB LINE (THIS SIDE OF BLADE UP)
10-32 x .30" PAN HEAD SCREWS (3)
REMOVE ONE PAN HEAD SCREW/LOCKWASHER
FLAT WASHERS (3)
FAN BLADE
BLADE FLANGE
MOTOR FLANGE
1/4-20 x 1/2" OVAL HEAD SCREWS (2)
MOTOR HUB
BLADE FLANGE
6. Remove and retain one of the three pan head screw/lockwashers from the motor flange (Figure 2); loosen the other two pan head screws three or four turns.
7. Position the switch cup adapter on the motor flange so that the two screws mate with the two keyhole slots in the switch cup adapter (Figure 2).
NOTE: Make sure that the lockwashers are positioned between the screw head and the switch cup adapter.
8. Turn the switch cup adapter clockwise
and tighten both screws (Figure 3). Reinstall the other pan head screw/ lockwasher in the remaining hole in the switch cup adapter.
9. Carefully rest the switch cup assembly on the fan blades, then engage the large (9-pin) connector of the switch cup assembly with the large motor connector (Figure 4). Connect the small (2-pin) connector of the switch cup assembly with the small motor connector. The two connectors are keyed and color-coded and must be mated correctly (color-to-color) before they can be engaged. Make sure the latches are engaged properly.
6
Figure 3
SWITCH CUP ASSEMBLY
SMALL (2-PIN) CONNECTORS
LARGE (9-PIN) CONNECTORS
Figure 4
10. Position the switch cup assembly on the switch cup adapter. Line up the three holes in the switch cup with the threaded holes in the switch cup adapter and install four 8-32 x 1/4” pan head screws (supplied) (Figure 5).
CAUTION: Before installing and tightening the screws, be sure there are no wires pinched between the switch cup adapter and switch cup assembly.
Figure 5
BP7305 Westfield 6/30/06 12:10 AM Page 6
MOTOR FLANGE
INSTALL ONE PAN HEAD SCREW/LOCKWASHER
SWITCH CUP ADAPTER
TIGHTEN TWO PAN HEAD SCREWS
PULL CHAIN
PENDANT
COUPLING
SWITCH CUP ADAPTER
8-32 x 1/4" PAN HEAD SCREW (4)
SWITCH CUP ASSEMBLY
7
11. Slip the longest pull chain through the hole in the large pendant (supplied) (Figure 5). Then secure the pendant by snapping the coupling (supplied) onto the end of the chain. Secure the small pendant (supplied) to the short chain in the same manner as above.
12. Carefully place the partially assembled ceiling fan on the lower styrofoam pad, with the switch cup assembly positioned in the opening and the blade assemblies resting on the outer rim of the styrofoam pad.
13. Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 6). Remove th pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in step 20.
Figure 6
14. Unscrew the two upper setscrews (Figure 7) until they clear the inside of the motor coupling. Then separate, untwist and unkink the three 80” motor leads. Route the motor lead wires through the downrod. Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the clevis pin and secure with the hairpin clip (Figure 7). The clevis pin must go through the holes in the motor coupling and the holes in the downrod. Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin.
!
WARNING
It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened. Failure to verify that the pin and setscrews are properly installed (as shown in Figure 7) could result in the fan falling.
The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull up on the downrod to make sure the clevis pin is properly installed.
15. Tighten the two upper setscrews (Figure 7) securely while pulling up on the downrod.
NOTE: The setscrews must be properly installed as described above, or fan wobble could result.
16. Install four 7-watt (maximum)
candelabra bulbs (not supplied) in the sockets on top of the motor housing (Figure 7).
17. Place the center glass on the rim of the fan motor and housing assembly; make sure the center glass is seated evenly in the housing flange (Figure 8).
CLEVIS PIN
HAIRPIN CLIP
MOTOR COUPLING
SETSCREW (2)
SOCKET
7-WATT (MAX.) CANDELABRA BULB (4)
Figure 7
BP7305 Westfield 6/30/06 12:10 AM Page 7
PIN
HANGER BALL
DOWNROD
SETSCREW
18. Slide the upper housing over the downrod until it rests on the center glass (Figure 8). Make sure the upper housing is seated firmly on the rim of the center glass, then tighten the three setscrews in the upper housing collar (Figure 9).
19. Make sure the grommet is properly installed in the upper housing cover, then slide the cover over the downrod until it rests on the upper housing (Figure 9).
8
SETSCREWS (3)
UPPER HOUSING COVER
GROMMET
COLLAR
UPPER HOUSING
Figure 9
Figure 8
20. Place the ceiling cover over the downrod. Then reinstall the hanger ball (Figure 10) on the downrod as follows. Route the three 80” motor leads through the hanger ball and slide the hanger ball over the downrod. Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball. Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball. A loose setscrew could create fan wobble.
Figure 10
21. The fan comes with blue, black and
white leads that are 80” long. Before installing the fan, measure up approximately 6 to 9-inches above top of hanger ball/downrod assembly. Cut off excess leads and strip back insulation 1/2” from end of leads.
22. You have now completed the initial
assembly of your new ceiling fan. You can now proceed with hanging and wiring your fan.
!
WARNING
It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling.
BP7305 Westfield 6/30/06 12:10 AM Page 8
UPPER HOUSING
FAN MOTOR AND HOUSING ASSEMBLY
CENTER GLASS
PIN
HANGERBALL
DOWNROD
CEILING COVER
SETSCREW
9
How to Hang
Your Ceiling Fan
The fan must be hung with at least 7' of clearance from floor to blades (Figure 11).
!
WARNING
The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs. Use only a U.L. outlet box listed as “Acceptable for Fan Support”.
!
WARNING
To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
!
WARNING
Figure 11
2. Carefully lift the fan and seat the hanger
ball/downrod assembly on the hanger bracket that was just attached to the outlet box (Figure 13). Be sure the groove in the ball is lined up with the tab on the hanger bracket (Figure 12).
1. Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box (Figure 12).
Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until bracket contacts box. If bracket and/or outlet box are not securely attached, the fan could wobble or fall.
!
WARNING
Figure 12
Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard.
!
WARNING
To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and hanger bracket.
!
WARNING
Figure 13
BP7305 Westfield 6/30/06 12:10 AM Page 9
CEILING
OUTLET BOX
AT
LEAST
7'
FLOOR
TWO SCREWS SUPPLIED WITH OUTLET BOX
TAB
NOTE: CEILING COVER, SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY.
HANGER BRACKET
HANGER BALL/ DOWNROD ASSEMBLY
1-1/4" THREADED STUD (2)
HANGER BRACKET
OUTLET BOX
10
How to Wire
Your Ceiling Fan
If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician.
CAUTION: To reduce the risk of electrical shock, disconnect the electri­cal supply circuit before installing the fan, light kit or receiver.
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse or circuit breaker box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
!
WARNING
Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result.
!
WARNING
1. If you are going to use an optional Emerson Remote Control/Receiver or Wall Control/Receiver to operate your ceiling fan, wire your fan in accordance with the Control/Receiver Owner’s Manual. After wiring, return to step 4.
2. If you are going to control your fan using two wall switches or optional Emerson fan/light controls, you will need a three-wire (with ground) conductor cable between the ceiling and wall outlet boxes. This will allow you to operate the fan housing lights and an optional Emerson Light Fixture (if installed) from one switch/control and the ceiling fan from a separate switch. Refer to Figure 14 and proceed as follows:
a. Connect the green grounding
lead from the hanger ball and the green grounding lead from the hanger bracket to the supply grounding conductor (this may be a bare wire or wire with green colored insulation). Securely connect wires with a wire connector (supplied).
b. Securely connect the fan motor
white wire to the supply white (neutral) wire using a wire connector (supplied).
c. Securely connect the fan motor
black wire to the supply black (hot) wire using a wire connector (supplied).
d. Securely connect the fan motor
blue wire to the supply red (hot) wire using a wire connector (supplied).
e. After connections have been
made, separate the white and green wires from the black, blue and red wires.
f. Carefully turn the wires upward
and insert them up through the open side of the hanger bracket and into the outlet box. Push the green and white wires into one side of the outlet box; push the black, blue and red wires into the other side of the outlet box.
BP7305 Westfield 6/30/06 12:10 AM Page 10
Figure 14
11
3. If you are going to use a single wall switch or optional Emerson fan control to control your ceiling fan, housing lights, and optional Emerson Light Fixture (if installed) simultane­ously, you will need a standard two­wire (with ground) conductor cable between the ceiling and wall outlet boxes. The fan speed and the housing lights can then be operated from the pull chain switches in the switch cup housing (or by an optional Emerson fan control); the optional light fixture can be operated from the light fixture switch. Refer to Figure 15 and proceed as follows: a. Connect the green grounding
lead from the hanger ball and the green grounding lead from the hanger bracket to the supply grounding conductor (this may be a bare wire or wire with green colored insulation). Securely connect wires with a wire connector (supplied).
b. Securely connect the fan motor
white wire to the supply white
(neutral) wire using a wire connector (supplied).
c. Securely connect the fan motor
black wire and blue wire to the supply black (hot) wire using a wire connector (supplied).
d. After connections have been
made, separate the white and green wires from the black and blue wires.
e. Carefully turn the wires upward
and insert them up through the open side of the hanger bracket and into the outlet box. Push the green and white wires into one side of the outlet box; push the black and blue wires into the other side of the outlet box.
Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result.
!
WARNING
BP7305 Westfield 6/30/06 12:10 AM Page 11
LISTED OUTLET BOX
GREEN WIRE (GROUND) FROM HANGER BRACKET
GROUND WIRE
BLACK FAN WIRE
BLACK
GREEN WIRE (GROUND) FROM HANGER BALL
LISTED WIRE CONNECTOR (4)
RED
WHITE
BLUE
GENERAL PURPOSE ON-OFF WALL SWITCHES OR OPTIONAL EMERSON FAN/LIGHT CONTROLS
THREE-CONDUCTOR CABLE (WITH GROUND) BETWEEN CEILING AND WALL OUTLET BOXES
FAN SWITCH
LIGHT
SWITCH
GROUND
WHT.
GROUND
BLACK (HOT)
TO 120 VOLT SUPPLY
4. Screw the two 1-1/4” threaded studs (supplied) into the tapped holes in the hanger bracket (Figure 13).
5. Lift the ceiling cover up to the threaded studs and turn until the studs protrude through the holes in the ceiling cover (Figure 16).
6. Secure the ceiling cover in place by sliding lockwashers (supplied) over the threaded studs and installing the two knurled knobs (supplied) (Figure 16). Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling.
12
To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling.
!
WARNING
Figure 15
Figure 16
7. Your ceiling fan is now installed, wired and ready for use.
BP7305 Westfield 6/30/06 12:10 AM Page 12
LISTED OUTLET BOX
GREEN WIRE (GROUND) FROM HANGER BRACKET
GROUND WIRE
BLACK FAN WIRE
BLACK
WHITE
BLUE
GREEN WIRE (GROUND) FROM HANGER BALL
LISTED WIRE CONNECTOR (3)
GENERAL PURPOSE ON/OFF
WALL SWITCH OR OPTIONAL
EMERSON FAN CONTROL
GROUND
TWO-CONDUCTOR CABLE (WITH GROUND) BETWEEN CEILING AND WALL OUTLET BOXES
WHT.
GROUND
BLACK (HOT)
TO 120 VOLT SUPPLY
LOCKWASHER (2)
KNURLED KNOB (2)
CEILING COVER
THREADED STUD (2)
13
Using Your Ceiling Fan Replacing Light Bulbs
Attaching Light Kit
1. Restore electrical power to the outlet box by turning the electricity on at the main fuse or circuit breaker box.
2. Check the operation of the fan by gently pulling on the 4-position speed control switch pull chain (large pendant) (Figure 17). The operating sequence is as follows:
THREE-SPEED 1st Pull—HIGH
2nd Pull—Medium 3rd Pull—Low 4th Pull—OFF
3. If airflow is desired in the opposite direction, turn your fan off and wait for the blades to stop turning. Then slide the reversing switch (located under the rubber boot) to the opposite position (Figure 17), and turn the fan on again. The fan blades will turn in the opposite direction and reverse the airflow.
4. Turn the housing lights on/off by gently pulling on the light control switch pull chain (small pendant) (Figure 17).
Figure 17
Figure 18
To replace a burned out light bulb, raise the upper housing cover on the downrod up to the ceiling cover (Figure 18). Loosen the setscrews in the upper housing collar, then raise the cover and remove the defective bulb from the socket. Screw in the replacement 7-watt (maximum) candelabra base bulb and lower the upper housing cover. Tighten the setscrews securely and slide the upper housing cover down the downrod.
CAUTION: To reduce the risk of electrical shock, disconnect the electri­cal supply circuit before installing the fan and optional light kit and/or remote control receiver.
To install an optional Emerson light kit, remove the four screws securing the switch cup assembly to the switch cup adapter. Remove the threaded plug from the switch cup and install the light kit in accordance with the light kit Owner’s Manual.
To avoid possible electrical shock, be sure electricity is turned off at the main service box before wiring.
!
WARNING
BP7305 Westfield 6/30/06 12:10 AM Page 13
REVERSING SWITCH (UNDER WATER-RESISTANT RUBBER BOOT)
SPEED CONTROL SWITCH PULL CHAIN
LIGHT CONTROL SWITCH PULL CHAIN
UPPER HOUSING
COLLAR
UPPER HOUSING COVER
SETSCREWS (3)
7-WATT (MAX.) CANDELABRA BULB
14
Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock.
!
WARNING
The use of any other control not specifically approved for this fan could result in fire, shock and personal injury.
!
WARNING
This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
!
WARNING
Maintenance
IMPORTANT CARE INSTRUCTIONS
for your Ceiling Fan
Periodic cleaning of your new ceiling fan is the only maintenance that is needed.
When cleaning, use only a soft brush or lint free cloth to avoid scratching the finish.
Abrasive cleaning agents are not required and should be avoided to prevent damage to finish.
Accessories
1. Ceiling Fan Light Kits (see store or catalog).
2. Downrod Extension Kits (see store or catalog).
3. Ceiling Fan/Light Controls (see store or catalog).
BP7305 Westfield 6/30/06 12:10 AM Page 14
15
Trouble Shooting
TROUBLE PROBABLE CAUSE SUGGESTED REMEDY
1. Fan will not 1. Fuse or circuit breaker 1. Check main and branch start. blown. circuit fuses or circuit
breakers.
2.Loose power line 2. Check power line connections connections to the fan, or to fan, and switch wire loose switch wire connections in the switch cup. connections in the switch cup.
WARNING: Make sure main power is turned off.
2. Fan sounds 1.Blades not attached to fan. 1. Attach blades to fan before noisy. operating.
2.Screws securing fan blade 2. Check to make sure the flanges to motor are loose. screws which attach the
blade flanges to the motor are tight.
3.Wire connectors inside 3. Check to make sure wire switch cup rattling. connectors in switch cup
are not rattling against each other or against the interior wall of the switch cup.
WARNING: Make sure main power is turned off.
4.Screws holding blades to 4. Tighten screws securely. flanges are loose.
5.Loose screws in motor 5. Check to make sure all housing. screws in motor housing
are snug (not over-tight).
3. Fan wobbles 1. Setscrews in motor coupling 1. Raise upper housing cover and excessively. are not tightened securely. and upper housing, then
tighten setscrews securely.
2.Setscrew in the hanger ball/ 2. Tighten the setscrew in the downrod assembly is loose. hanger ball/downrod
assembly.
3.Screws securing fan blade 3. Check to be sure screws flanges to motor are loose. which attach the fan blade
flanges to the motor are tight.
4.Fan blade flanges not 4. Check to be sure that the seated properly. fan blade flanges seat firmly
and uniformly to the surface of the motor. If flanges are seated incorrectly, loosen the flange screws and retighten according to Step 5 and Figure 2.
5.Hanger bracket and/or 5. Tighten the hanger bracket ceiling outlet box is not screws to the outlet box, securely fastened. and/or secure outlet box.
6.Fan blades out of balance. 6. Interchanging an adjacent
(side-by-side) blade pair can redistribute the weight and result in smoother operation. Or use supplied balancing kit to balance blades.
WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX
OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN.
!
!
!
BP7305 Westfield 6/30/06 12:10 AM Page 15
Repair Parts
Before discarding packaging material, be certain all parts have been removed.
HOW TO ORDER REPAIR PARTS
WHEN ORDERING REPAIR PARTS, ALWA YS GIVE THE FOLLOWING INFORMATION:
• PART NUMBER
• NAME OF ITEM
• PART DESCRIPTION
• MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing. For repair parts, phone 1-800-654-3545.
16
BP7305 Westfield 6/30/06 12:10 AM Page 16
1
5
2
3
21
20
4
7
10 11
12
16
17
6
18
19
8
26
9
22
25
13
15
24
23
14
15
Part Numbers
Key Model No. Model No. Model No.
No. Description CF680BQ00 CF680ORB00 CF680WB00
* Hanger Pack, Consisting of: 761655-49 761655-50 761655-48 1 Hanger Bracket — 2 Hanger Ball — 3 Downrod
* Parts Bag, Containing: 762952 762952 762952 4 Wire Connector (5) — 5 Threaded Stud 8-32 x 1/14” (2) — 6 Knurled Knob (2) — 7 Lockwasher (2) — 8 Hairpin Clip
9 Clevis Pin — 10 Screw, Pan Head 10-32 x .30” (16) — 11 Washer, Flat (16) — 12 Screw, Oval Head 1/4-20 x 1/2” (11) — 13 Pendant, Large — 14 Pendant, Small — 15 Coupling, Chain (2)
16 Cover, Ceiling 762649-BQ 762649-ORB 762649-WB 17 Cover, Upper Housing 762940-BQ 762940-ORB 762940-WB 18 Housing, Upper 762941-BQ 762941-ORB 762941-WB 19 Glass, Center 762942 762942 762942 20 Flange Set (full set for one fan) 762945-BQ 762945-ORB 762945-WB 21 Blade Set (full set for one fan) 762947 762947 762947 22 Adapter, Switch Cup 762949 762949 762949 23 Cup Assembly, Switch 762950-BQ 762950-ORB 762950-WB 24 Nut, Finial 762951-BQ 762951-ORB 762951-WB 25 Harness, Electrical 762953 762953 762953 26 Harness, Housing Lights 762954 762954 762954 — Owner's Manual BP7305 BP7305 BP7305
Repair Parts Listing
17
BP7305 Westfield 6/30/06 12:10 AM Page 17
18
Notes
BP7305 Westfield 6/30/06 12:10 AM Page 18
19
Notes
BP7305 Westfield 6/30/06 12:10 AM Page 19
Part No. F40BP73050001 Printed in China 07/06 Form No. BP7305-1
Air Comfort Products
DIVISION OF EMERSON ELECTRIC CO.
8100 W. Florissant ¥ St. Louis, MO 63136
BP7305 Westfield 6/30/06 12:10 AM Page 20
Loading...