Emerson CF4600GLZ00, CF4600WB00 User Manual

LIMITED WARRANTY
What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered.
What The Period Of Coverage Is:
As it applies to the motor, this warranty will last for a lifetime of your ceiling fan. All other components and accessories are covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.
What W
ill Emerson Electric Co. Do To Correct Problems:
Emerson Electric Co. will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no charge to you. If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson will refund the actual purchase price of your fan. WE WILL SHIP THE REPAIRED PRODUCT OR REPLACEMENT TO YOU AT NO CHARGE, BUT YOU ARE
RESPONSIBLE FOR ALL COSTS OR REMOVAL, REINSTALLATION AND SHIPPING OF THE PRODUCT TO EMERSON ELECTRIC CO. How Can Y
ou Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division of Emerson Electric Co., 8100 W. Florissant Ave., St. Louis, MO63136. Include all model numbers shown on the product with your request.
• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center.
You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage.
What Is Not Cover
ed:
The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does not cover any defects, malfunctions or failures caused by:
• Repairs by persons not authorized by Emerson Electric Co.,
• Use of parts or accessories not authorized by Emerson Electric Co.,
• Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or
• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.
Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:
• The original purchaser or user ceases to own the product, or
• The fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no employee, agent, dealer or other person is authorized to give any warranties on behalf of Emerson Electric Co.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to such damages as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if this product does not work properly.
How State Law Relates T
o The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Part No. F40BP73060001 Form No. BP7306-1
U.L. Model No.: CF4600
READ AND SAVE THESE INSTRUCTIONS
NOTTINGHAM
Net Weight: 27.1 Lbs.
54” Ceiling Fan
Owner's Manual
CF4600GLZ00 CF4600WB00
Model No.
BP7306 Nottingham 6/19/06 1:00 PM Page 1
2
WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.
Safety Instructions
1. Read your owner’s manual carefully and keep it for future reference.
2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.
3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.
4. Do not put anything into the fan blades while they are turning.
5. Do not operate reversing switch until fan blades have come to a complete stop.
Additional Safety Instructions for Installation
1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.
2. The installation is to be in accordance with the National Electrical Code, ANSI/NFPA70-1999 and Local Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.
3. The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support”, and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
4. The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for a 9 foot ceiling. This fan should NOT be mounted on an 8 foot ceiling.
5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.
6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.
WARNING: To reduce the risk of fire or electric shock, this fan should only be used with fan speed control Model No. UC7067RC, manufactured by Rhine Electric Co., Ltd.
NOTE: This fan is suitable for use with solid-state speed controls. WARNING: This product is designed to use only those parts supplied with this
product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
WARNING: To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
WARNING: To reduce the risk of electrical shock, this fan must be installed with an isolating wall control/switch.
!
WARNING
DATE CODE:
The date code of this fan may be found on the box, stamped in ink on a white label. You should record this data above and keep it in a safe place for future use.
BP7306 Nottingham 6/19/06 1:00 PM Page 2
3
This Manual is Designed to Make it as Easy as Possible for You to
Assemble, Install, Operate and Maintain Your Ceiling Fan
Do not install or use fan if any part is damaged or missing. Call Toll-Free:
1-800-654-3545
!
WARNING
This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
!
WARNING
Tools Needed for Assembly
One Phillips head screwdriver One wire stripper One stepladder Five wire connectors (supplied) Six 7-watt (max.) candelabra bulbs
Materials
Wiring, outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of the following sizes:
Installed Wire Length Wire Size A.W.G.
Up to 50 ft. 14 50-100 ft. 12
Before assembling your ceiling fan, refer to section on proper method of wiring your fan (page 10). If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.
!
WARNING
Unpacking Instructions
For your convenience, check-off boxes are provided next to each step. As each step is completed, place a check mark in the box. This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted.
NOTE: If you are uncertain of part description, refer to exploded view illustration.
a. Fan motor and housing assembly b. One ceiling cover c. One coupling cover d. One upper housing e. One upper glass f. Three housing trims g. Five blade flanges h. Five fan blades i. One hanger bracket j. One hanger ball/downrod assembly k. One switch cup assembly l. One SW101 Fan/Light Wall Control
(transmitter and receiver)
1. Open styrofoam unit containing fan. Remove top half of styrofoam unit. Remove parts and check to see that you have received the following parts:
BP7306 Nottingham 6/19/06 1:00 PM Page 3
4
m. One loose parts bag containing:
1. Two 8-32 x 1-1/4” threaded studs
2. Two 8-32 x 1” threaded studs
3. Four knurled knobs
4. Four lockwashers
5. Five wire connectors
6. One clevis pin/hairpin clip assembly
7. Eleven 5-32 x 9/16” pan head screws
8. Sixteen 10-32 x 1/2” pan head screws
9. Sixteen #10 flat washers
10. One 5/16-18 x 1/4” setscrew
11. One hex wrench
12. Six 8-32 x 1/2” pan head screws
2. Remove the fan motor and housing assembly from the protective plastic bag. Place the fan assembly into the lower foam pad with the bottom of the motor facing up.
The lower foam pad serves as a holder for the fan during the first stages of assembly.
Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.
The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.
To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
!
WARNING
If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse or circuit breaker box at this time and remove the existing light fixture.
Electrical Requirements
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse or circuit breaker box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
!
WARNING
IMPORTANT: Your ceiling fan will not function properly, and may be damaged, if used with any wall dimmer switch or control other than the Emerson Electric Fan/Light Wall Control supplied with the fan, or an optional Emerson Electric SR100 Remote Control.
NOTE: Place the parts from the loose parts bags in a small container to keep them from being lost.
BP7306 Nottingham 6/19/06 1:00 PM Page 4
A
C
FAN OFF
EMERSON
I
L
HI
LIGHT
MED
LOW
ONOFF
J
L
ON
1 2 3 4
B
D
E
F
G
H
K
M
5
1. Mount the fan blades to the blade flanges using three 10-32 x 1/2” pan head screws and three #10 flat washers (screws and washers supplied) (Figure 1).
How to Assemble Your
Ceiling Fan
To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
!
WARNING
Figure 1
General
Your Emerson ceiling fan comes supplied with a Fan/Light Wall Control which consists of a wall control (transmitter) and a remote control receiver mounted under the ceiling cover. This system allows you to regulate your ceiling fan speed and light intensity.
NOTE: An optional Emerson Electric SR100 Remote Control may also be used to control your ceiling fan.
Ceiling Fan Procedures
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse or circuit breaker box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
!
WARNING
IMPORTANT: Before assembling your ceiling fan, refer to sections “Setting Operating Frequency of Wall Control and Receiver” and “Installation of Wall Control”, page 13. These sections instruct you how to: a) Set the operating frequency of the fan/light wall control and the remote control receiver; and b) Install the fan/light wall control in the wall box. You will then be ready to proceed with the assembly and installation of your ceiling fan, as follows:
NOTE: Take care not to scratch the fan finish when installing the blade assemblies.
2. Insert a blade flange into one of the
round holes in the mounting hub (Figure 2). Insert one 5/32 x 9/16” pan head screw (supplied) in one of the flange mounting holes; do not tighten. Install the second screw in the same manner; tighten both screws securely. Repeat this procedure for the other four blade assemblies.
!
WARNING
To reduce the risk of personal injury, do not bend the blade flanges when installing the flanges, balancing the blades or cleaning the fan. Do not insert foreign objects between rotating fan blades.
BP7306 Nottingham 6/19/06 1:00 PM Page 5
10-32 x 1/2" PAN HEAD SCREWS (3)
#10 FLAT WASHERS (3)
FAN BLADE
BLADE FLANGE
3. Carefully rest the switch cup assembly on the fan blades, then engage the connector of the switch cup assembly with the motor connector (Figure 3). The two connectors are keyed and must be mated correctly before they can be engaged. Make sure the connectors are engaged properly.
4. Remove and retain four pan head screws from the rim of the switch cup adapter (Figure 3).
5. Position the switch cup assembly on the switch cup adapter. Line up the four holes in the switch cup with the threaded holes in the switch cup adapter and reinstall four pan head screws (previously removed) (Figure
4).
CAUTION: Before installing and tightening the screws, be sure there are no wires pinched between the switch cup adapter and switch cup assembly.
6
Figure 2
Figure 3
SWITCH CUP ASSEMBLY
REINSTALL FOUR PAN HEAD SCREWS
Figure 4
6. Carefully place the partially assembled ceiling fan on the lower styrofoam pad, with the switch cup assembly positioned in the opening and the blade assemblies resting on the outer rim of the styrofoam pad.
7. Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 5). Remove th pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in step 19.
BP7306 Nottingham 6/19/06 1:00 PM Page 6
5/32 x 9/16" PAN HEAD SCREWS (2)
MOUNTING HUB
BLADE FLANGE
SWITCH CUP ASSEMBLY
CONNECTORS
REMOVE AND RETAIN FOUR PAN HEAD SCREWS
SWITCH CUP ADAPTER
Loading...
+ 14 hidden pages