Emerson CF430BS00, CF430ORB00, CF430SW00 Owner's Manual

Part No. F40BP74860000 Form No. BP7486 Revision: 131212 ETL Model No.: CF430
READ AND SAVE THESE INSTRUCTIONS
HIGHRISE
50” Ceiling Fan Owner's Manual
CF430BS00
CF430SW00
Satin White
Model Numbers
CF430ORB00
Oil Rubbed Bronze
Net Weight: 24.3 Lbs.
Questions, problems, missing parts: Before returning to the store call
Emerson Electric Customer Service
8 a.m. - 6 p.m., Eastern, Monday-Friday
1-800-654-3545
www.emersonfans.com
BP7486 CF430 Highrise OM 12/13/13 10:35 AM Page 1
2
Safety Instructions
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a. Use this unit only in a manner intended by the
manufacturer. If you have questions, contact the manufacturer.
b. Before servicing or cleaning unit, switch power off
at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.
WARNING
!
Additional Safety Instructions for Installation
1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.
2. All wiring must be in accordance with the National Electrical Code “ANSI/NFPA 70-2014” and Local Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.
3. The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support of 22.7 kg. (50 lbs.) or less”, and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
4. The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling.
5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.
6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.
WARNING: To reduce the risk of electrical shock, this fan must be installed with an isolating wall control/ switch.
NOTE: This fan is suitable for use with solid-state speed controls.
WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson could result in personal injury or property damage.
WARNING: To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
WARNING: To avoid fire, shock or injury, do not use an Emerson or any other brand of control not specifically approved for this fan.
NOTE: All setscrews must be checked and re-tightened where necessary before installation.
1. Read your owner’s manual carefully and keep it for future reference.
2. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.
3. Do not put anything into the fan blades while they are turning.
4. Do not operate reversing switch until fan blades have come to a complete stop.
DATE CODE:
The date code of this fan may be found on the box, stamped in ink on a white label. You should record
this data above and keep it in a safe place for future use.
ETL Model No.: CF430
READ AND SAVE THESE INSTRUCTIONS
Table of Contents
Section Page
Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1. Unpacking Instructions . . . . . . . . . . . . . . . . . . . . . . . . .3-4
2. Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . .4
3. Ceiling Fan Assembly . . . . . . . . . . . . . . . . . . . . . . . . . .5-6
4. How to Hang Your Ceiling Fan . . . . . . . . . . . . . . . . . . .7-8
5. How to Wire Your Ceiling Fan . . . . . . . . . . . . . . . . . . .9-10
6. Final Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-13
Section Page
7. Wall Control Procedures . . . . . . . . . . . . . . . . . . . . . .14-18
8. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
9. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
10. Repair Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20-21
11. Trouble Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
12. Remote Control Trouble Shooting . . . . . . . . . . . . . . . .22
Ceiling Fan Limited Warranty . . . . . . . . . . . . . . . . . . . . . . .23
BP7486 CF430 Highrise OM 12/13/13 10:35 AM Page 2
1. Unpacking Instructions
3
emersonfans.com
Please contact 1-800-654-3545 for further assistance
ETL Model No.: CF430
This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
WARNING
!
Do not install or use fan if any part is damaged or missing. Call Toll-Free:
1-800-654-3545
WARNING
!
1.1
Check to see that you have received the following parts:
NOTE: If you are uncertain of part description, refer to exploded view illustration.
1.2
Remove the fan motor assembly from the protective plastic bag. Place the fan assembly into the upper foam pad with the bottom of the motor facing up.
The upper foam pad serves as a holder for the fan during assembly.
HARDWARE CONTENTS
Part Description Quantity
1 Threaded Studs, #8-32 x 1-1/4” 2
2 Knurled Knobs, #8-32 2
3 Lockwashers, External Tooth #8 2
4 Wire Connectors, 12 ga. 5
5 Clevis Pin 1
6 Hairpin Clip 1
7 Screw, Washer Head, #8- 32 x 11mm 10
8 Screw, Truss Head, #6- 32 x 3/8” (spare) 1
9 Screw, Truss Head, #8- 32 x 3/8” (spare) 1
10 Blade Balance Kit 1
PACKAGE CONTENTS
Part Description Quantity
A Fan Motor Assembly 1 B Ceiling Cover 1 C Coupler Cover 1 D Light Kit Plate Adapter 1 E Light Fixture Assembly - LED 1 F Glass Shade Assembly 1 G Fan Blades 4 H Hanger Bracket 1
I Hanger Ball/4.5” Downrod Assembly 1 J RCFP Receiver 1 K SW406 Wall Control 1
NOTE: Place the parts from the loose parts bags in a small container to keep them from being lost. If any parts are missing, contact your local retailer or catalog outlet for replacement before proceeding.
BP7486 CF430 Highrise OM 12/13/13 10:35 AM Page 3
1
23
56
A
B
C
D
....
OFF ON
4
7
E
F
H
I
ON
J
K
G
8
9
10
Before assembling your ceiling fan, refer to section on proper method of wiring your fan (page 9). If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.
WARNING
!
This Manual Is Designed to Make it as Easy as Possible for You to Assemble,
Install, Operate and Maintain Your Ceiling Fan
Tools Needed for Assembly
One Phillips head screwdriver One stepladder One 1/4” blade screwdriver One wire stripper
Materials
Wiring outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of following size:
Installed Wire Length Wire Size A.W.G.
Up to 50 ft. 14
50-100 ft. 12
4
ETL Model No.: CF430
2. Electrical Requirements
Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.
To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support of 22.7 kg. (50 lbs.) or less”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
WARNING
!
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
WARNING
!
To avoid fire or shock, follow all wiring instructions carefully.
Any electrical work not described in these instructions should be done or approved by a licensed electrician.
WARNING
!
The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.
If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.
1. Unpacking Instructions (continued)
BP7486 CF430 Highrise OM 12/13/13 10:35 AM Page 4
3. Ceiling Fan Assembly
5
emersonfans.com
Please contact 1-800-654-3545 for further assistance
ETL Model No.: CF430
Figure 1
3.1
Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 1). Remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in Step 3.6.
Figure 2
It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened. Failure to verify that the pin and setscrews are properly installed could result in the fan falling.
WARNING
!
3.2
Loosen setscrew in motor coupling if necessary. Separate, untwist and unkink the three 80” motor leads. Route the motor lead wires through the downrod. Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the clevis pin and secure with the hairpin clip (Figure 2). The clevis pin must go through the holes in the motor coupling and the holes in the downrod. Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull on the downrod to make sure the clevis pin is properly installed.
Figure 3
3.3
While pulling up on the downrod, securely tighten the two setscrews in the motor coupling (Figure 3).
NOTE: The setscrews must be properly installed as described above, or fan wobble could result.
3.4
Make sure the grommet is properly installed on the coupler cover then slide the coupler cover on the downrod until it rests on the motor housing (Figure 3).
BP7486 CF430 Highrise OM 12/13/13 10:35 AM Page 5
PIN
HANGER BALL
SETSCREW (2)
SETSCREW
CLEVIS PIN
CLEVIS PIN
SETSCREW
DOWNROD
DOWNROD
DOWNROD
HAIRPIN CLIP
MOTOR COUPLING
HAIRPIN CLIP
MOTOR COUPLING
GROMMET
SETSCREW (2)
DOWNROD
COUPLER COVER
6
ETL Model No.: CF430
3. Ceiling Fan Assembly (continued)
3.5
Place the ceiling cover over the downrod. Be sure both the ceiling cover and the coupler cover are oriented correctly (Figure 4).
Figure 4
Figure 5
3.6
Reinstall the hanger ball (Figure 5) on the downrod as follows. Route the motor leads through the downrod. Position the pin through the two holes in the downrod and align the ball so the pin is captured in the groove in the top of the hanger ball. Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball. A loose setscrew could create fan wobble.
3.7
The fan comes with blue, black and white leads that are 80-inches long. Before installing the fan, measure up approximately 6 to 9-inches above top of hanger ball/downrod assembly. Cut off excess leads and strip back insulation 1/2-inch from end of leads.
It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling.
WARNING
!
BP7486 CF430 Highrise OM 12/13/13 10:35 AM Page 6
DOWNROD
PIN
SETSCREW
CEILING COVER
COUPLER COVER
HANGER BALL
DOWNROD
7
emersonfans.com
Please contact 1-800-654-3545 for further assistance
ETL Model No.: CF430
Figure 6
4. How to Hang Your Ceiling Fan
The fan must be hung with at least 7' of clearance from floor to blades (Figure 6).
WARNING
!
The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs. Use only a U.L. outlet box listed as “Acceptable for Fan Support of
22.7 kg. (50 lbs.) or less”.
WARNING
!
To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support of 22.7 kg. (50 lbs.) or less”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
WARNING
!
4.1
Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box. (Figure 7.)
Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until bracket contacts box. If bracket and/or outlet box are not securely attached, the fan could wobble or fall.
WARNING
!
Figure 7
BP7486 CF430 Highrise OM 12/13/13 10:35 AM Page 7
CEILING
AT LEAST
7'
FLOOR
OUTLET BOX
HANGER BRACKET
TWO SCREWS SUPPLIED WITH OUTLET BOX
TAB
8
ETL Model No.: CF430
4. How to Hang Your Ceiling Fan (continued)
4.2
Screw the two 1-1/4” threaded studs (supplied) into the tapped holes in the hanger bracket (Figure 8).
Figure 8
To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and hanger bracket.
WARNING
!
Failure to seat the anti-rotation tab in groove could cause damage to electrical wires and possible shock or fire hazard.
WARNING
!
Figure 9
4.3
Carefully lift the fan and seat the hanger ball/ downrod assembly into the hanger bracket that was just attached to the outlet box (Figure 9). Be sure the groove in the ball is lined up with anti-rotation tab on the hanger bracket (Figure 9).
BP7486 CF430 Highrise OM 12/13/13 10:35 AM Page 8
OUTLET BOX
HANGER BRACKET
1-1/4" THREADED STUDS (2)
ANTI-ROTATION TAB
NOTE: CEILING COVER, SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY.
OUTLET BOX
HANGER BRACKET
HANGER BALL/ DOWNROD ASSEMBLY
Loading...