Emerson CF3200AWL00 User Manual

READ AND SAVE THESE INSTRUCTIONS
Part No. F40BP73500000 Form No. BP7350
U.L. Model No.: CF3200
Net Weight: 26.0 Lbs.
Model Numbers
BATON ROUGE
Owner's Manual
CF3200AWL00
Summer White
w/Latte Highlights
CF3200DBZ00
Distressed Bronze
2
WARNING
!
WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.
Safety Instructions
1. Read your owner’s manual carefully and keep it for future reference
2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.
3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.
4. Do not put anything into the fan blades while they are turning.
5. Do not operate reversing switch until fan blades have come to a complete stop.
Additional Safety Instructions for Installation
1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.
2. All wiring must be in accordance with the National Electrical Code “ANSI/NFPA 70-1999” and Local Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.
3. The outlet box and joist must be securely mounted an capable of reliably supporting a least 50 pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support”, and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
4. The longer downrod (12”) furnished with the ceiling fan provides the minimum recommended floor-to-fan blade clearance for a 9-foot ceiling. The 6” downrod (supplied) is to be used for shorter ceilings.
5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with th fan blades.
6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.
NOTE: This fan is suitable for use with solid-state speed controls. WARNING: To reduce the risk of fire or electrical shock, this fan should only be used with fan
speed control, Model No. SW105, manufactured by Rhine Electric Co., Ltd. WARNING: To avoid fire, shock or injury, do not use an Emerson or any other brand of control not
specifically approved for this fan. WARNING: This product is designed to use only those parts supplied with this product and/or any
accessories designated specifically for use this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson could result in personal injury or property damage.
WARNING: To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
WARNING: To reduce the risk of electrical shock, this fan must be installed with an isolating wall control/switch.
DATE CODE:
The date code of this fan may be found on
the box, stamped in ink on a white label.
You should record this data above and keep
it in a safe place for future use.
U.L. Model No.: CF3200
3
This Manual Is Designed to Make it as Easy as Possible for You to
Assemble, Install, Operate and Maintain Your Ceiling Fan
One stepladder One wire stripper One Phillips head screwdriver Four 15-watt (max.) candelabra base bulbs
MATERIALS
Wiring outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of the wire size, to right:
Installed Wire Length Wire Size A.W.G.
Up to 50 ft. 14
50-100 ft. 12
If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.
WARNING
!
Unpacking Instructions
For your convenience, check-off boxes are provided next to each step. As each step is completed, place a check mark in the box. This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted.
Do not install or use fan if any part is damaged or missing. Call Toll-Free:
1-800-654-3545
This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
WARNING
!
WARNING
!
1. Open styrofoam unit containing fan. Remove upper
and center sections of styrofoam unit. Remove parts and check to see that you have received the following:
a. One Fan Motor and Housing Assembly b. One Motor Coupling Cover c. One Ceiling Cover d. Five Fan Blades e. Five Flanges f. Five Flange Medallions g. One Hanger Ball/12” Downrod Assembly h. One Hanger Bracket i. One 6” Downrod j. One Light Kit Assembly k. One Light Kit Glass l. One Switch Housing m. One Decorative Downrod Cover n. Four Decorative Scrolls o. One Scroll Collar p. One SW116 Fan/Light Wall Control
(transmitter) Includes Three Covers q. One SW105 Receiver r. One Loose Parts Bag Containing:
1. One 5/16-18 x 1/4” setscrew
2. One 5/32" hex wrench
3. Four 8-32 x 1-1/4” threaded studs
4. Four #8-32 knurled knobs
Tools Needed for Assembly
5. Four #8 external tooth lockwashers
6. Five 12 Ga. wire connectors
7. One hairpin clip
8. One clevis pin
9. Twenty-one 10-32 x 10mm pan head screws
10. Eleven #8-32 x 14mm oval head screws
11. Four #8-32 x 10mm flat head screws
12. Five #8-32 x 15mm flat head screws
13. One balancing kit
NOTE: Place the parts from the loose parts bags in small containers to keep them from being lost. If any parts are missing, contact your local retailer or catalog outlet for replacement before proceeding.
U.L. Model No.: CF3200
a.
10-32 x 10mm PAN HEAD SCREW
(4 Per Blade) 10-32 x 10mm PAN HEAD SCREW (4 Per Blade)
10-32 x 10mm PAN HEAD SCREW (4 Per Blade)
10-32 x 10mm PAN HEAD SCREW
FLANGE
(4 Per Blade)
BLADE
FLANGE MEDALLION
e.
BLADE
BLADE
FLANGE
MEDALLION
BLADE
FLANGE FLANGE ASSEMBLY
MEDALLION FLANGE FLANGE ASSEMBLY MEDALLION
BLADE
FLANGE FLANGE ASSEMBLY MEDALLION
FLANGE ASSEMBLY
ASSEMBLY
b.
c.
10-32 x 10mm PAN HEAD SCREW (4 Per Blade)
d.
f.
h.
i.
j.
g.
m.
k.
H I H I
L I G
H
T
M E
D M E
D
L
O
W L O
W
R E
V R E V
F A N
O F
F
n.
o.
p.
l.
q.
r.
1. Place the flange assembly onto the bottom of the
blade assembly. Place the flange medallion assembly into the four holes of the blade assembly.
2. Secure the flange assembly and flange medallion
to the blade assembly using the four #10-32 x 10mm pan head screws. Repeat for the four remaining blades. (Figure 1)
3. Place the motor housing assembly onto the
styrofoam for blade assembly installation.
4. Rotate the switch housing plate to align the holes
in the blade flange assembly with the holes in the motor housing.
NOTE: Take care not to scratch fan housing when installing blades.
5. Attach the flange assembly using two #8-32 x
14mm oval head screws (supplied) (Figure 2). Install the remaining four fan blades assemblies using the same procedure.
6. Gently snug all flange screws to the motor
housing, working around the housing in a clockwise sequence. Next, securely tighten all flange screws, again working in a clockwise sequence. Failure to follow this procedure could result in fan wobble. This completes the blade installation.
Figure 1
Figure 2
If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with national and local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
WARNING
!
Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.
The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.
To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
WARNING
!
Electrical Requirements
Ceiling Fan Assembly
Procedures
To avoid possible fire or shock, follow all wiring instructions carefully. Any electrical work not described in these instructions should be done or approved by a licensed electrician.
WARNING
!
4
IMPORTANT: Your ceiling fan is supplied with an SW116 Fan/Light Wall Control (transmitter) and a remote control SW105 Receiver which mounts under the ceiling cover. This system allows you to regulate your ceiling fan speed, airflow direction, and light intensity. An optional Emerson Electric SR110 Remote Control may also be used.
IMPORTANT: Your ceiling fan will not function properly and may be damaged, if used with any wall dimmer switch or control other than the Emerson controls listed above.
Preliminary Procedures
IMPORTANT: Before assembling your ceiling fan, refer to sections “Setting Operating Frequency of Wall Control and Receiver” and “Installation of Wall Control”, Page 11. These sections instruct you how to:
a. Set the operating frequency of the fan/light wall
control and the remote control receiver.
b. Install the fan/light wall control in the wall box.
You will then be ready to proceed with the assembly and installation of your ceiling fan.
To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
WARNING
!
U.L. Model No.: CF3200
10-32 x 10mm PAN HEAD SCREW (4 Per Blade)
FLANGE ASSEMBLY
BLADE
FLANGE MEDALLION
MOTOR HOUSING
#8-32 x 14mm OVAL HEAD SCREW (2 Per Flange Assembly)
FLANGE ASSEMBLY
7. Remove the wire connector from the white wire of
the switch housing plate. Retain for the next step.
8. Connect the white wire from the switch housing
plate to the white wire of the switch housing, using the wire connector previously removed (Figure 3).
9. Connect the 9-pin connector from the switch
housing plate to the 9-pin connector of the switch housing (Figure 3).
10. Tuck all wires into the switch housing, opposite of
the switch housing notched hole (Figure 4).
NOTE: Be sure wires are on the opposite side of the notched hole before securing the switch housing.
11. Secure the switch housing to the switch housing
plate using three #8-32 x 10mm flat head screws (supplied) (Figure 5).
5
Figure 3
Figure 4
Figure 5
Figure 6
Figure 7
12. Carefully turn over the partially assembled ceiling
fan and place the onto the flat surface of the styrofoam (Figure 6).
13. Gently place the light kit glass into the decorative
light kit ring (Figure 7).
14. Rotate the rubber clips to secure glass into place.
(Figure 7). You may need to tighten the screws on the rubber clips to secure.
U.L. Model No.: CF3200
NOTE: If installing an optional Emerson light kit, follow the instructions provided with the light kit.
NOTE: It may be necessary to remove the rubber clips in order to install the light kit glass. Make sure rubber clips are reinstalled so as to securely hold the light kit glass.
SWITCH HOUSING WHITE WIRE
SWITCH HOUSING
WIRE CONNECTOR
SWITCH HOUSING PLATE WHITE WIRE
9-PIN CONNECTOR
SWITCH HOUSING
PARTIALLY ASSEMBLED CEILING FAN
STYROFOAM
RUBBER CLIP SCREW
RUBBER CLIP (3)
LIGHT KIT GLASS
ALL WIRES AND CONNECTORS LOCATION
SWITCH HOUSING PLATE NOTCHED HOLE
SWITCH HOUSING
#8-32 x 10mm FLAT HEAD SCREW (3)
DECORATIVE LIGHT KIT RING
LIGHT KIT GLASS
Loading...
+ 11 hidden pages