Emerson CF2454WW02, CF2454BS02, CF2454PW02, CF2454BQ02 User Manual

READ AND SAVE THESE INSTRUCTIONS
Model No.
CF2454WW02 CF2454BS02 CF2454PW02 CF2454BQ02
THE ODYSSEY Series Ceiling Fan Owner's Manual
Part No. F40BP72110008 Form No. BP7211-8
®
WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.
Safety Instructions
1. Read your owner’s manual carefully and keep it for future reference
2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service dis­connecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.
3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.
4. Do not put anything into the fan blades while they are turning.
5. Do not operate reversing switch until fan blades have come to a complete stop.
Additional Safety Instructions for Installation
1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.
2. All wiring must satisfy National and Local Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.
3. The outlet box and joist must be securely mounted an capable of reliably supporting a least 50 pounds. Use only U.L. outlet boxes listed as acceptable for fan support, and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
4. The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling.
5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with th fan blades.
6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.
WARNING: To avoid fire, shock or injury, do not use an Emerson or any other brand of control not specifically approved for this fan.
WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use this product by Emerson Company could result in personal injury or property damage.
WARNING: To Reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
2
WARNING
!
1. Open styrofoam unit containing fan. Remove upper and center sections of styrofoam unit. Remove parts and check to see that you have received the following:
a. One fan motor and housing assembly b. One motor coupling cover c. One ceiling cover d. Five fan blades e. Five blade holder caps (left) f. Five blade holder caps (right) g. One hanger ball/downrod assembly h. One hanger bracket i. One light kit adapter assembly j. One light kit plate assembly k. One light kit glass l. Two die cast light kit glass holders m.One uplight lead assembly n. One loose parts bag containing:
1. One setscrew
2. One 5/32" hex wrench
3. One 3/16” hex wrench
4. Four 8-32 x 1-1/4” threaded studs
5. Four knurled knobs
6. Four lockwashers
7. Seven wire connectors
8. Three 8-32 x 3/8" phillips head screws
9. One hairpin clip
10. One clevis pin
11. Twenty-one 10-32 x 3/8" pan head screws
12. One flatwasher
This Manual Is Designed to Make it as Easy as Possible for You to
Assemble, Install, Operate and Maintain Your Ceiling Fan
Tools Needed for Assembly
One six-inch blade screwdriver One stepladder One Phillips head screwdriver One wire stripper Seven wire connectors(supplied.)
MATERIALS
Wiring outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of the wire size, to right:
3
Installed Wire Length Wire Size A.W.G.
Up to 50 ft. 14
50-100 ft. 12
Unpacking Instructions
For your convenience, check-off boxes are provided next to each step. As each step is completed, place a check mark in the box. This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted.
If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.
NOTE: Place the parts from the loose parts bags in small containers to keep them from being lost. If any parts are missing, contact your local retailer or catalog outlet for replacement before proceeding.
Do not install or use fan if any part is damaged or missing. Call Toll-Free:
1-800-654-3545
This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Company. Substitution of parts or acces­sories not designated for use with this product by Emerson Company could result in personal injury or property damage.
WARNING
!
WARNING
!
WARNING
!
FAN BLADES
MOTOR COUPLING COVER
UPPER STYROFOAM SECTION
BLADE HOLDER CAPS (LEFT)
BLADE HOLDER
CAPS (RIGHT) DIE CAST GLASS HOLDERS
LIGHT KIT GLASS
CEILING COVER
LIGHT KIT PLATE ASSEMBLY
LOWER STYROFOAM SECTION
FAN MOTOR AND HOUSING ASSEMBLY
UPLIGHT LEAD ASSEMBLY
HANGER BALL/ DOWNROD ASSEMBLY
HANGER BRACKET
LOOSE PARTS BAG
CENTER STYROFOAM SECTION
LIGHT KIT ADAPTER ASSEMBLY
Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.
The outlet box must be securely anchored and capa­ble of withstanding a load of at least 50 pounds.
If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician.
4
SECTION A
Assembly Instructions
for Installing the CF2454
Ceiling Fan with a
SW375 Receiver and
a SR330 Remote Control or
with a SW350 Wall Control
1. Cut the white, blue, and black wires about 3" above the motor coupling (Figure 1). Strip insula­tion 1/2" from end of wires and install a wire con­nector on the black wire; this wire will not be used. Remove the wire connectors from the red and brown wires.
2. Loosen the setscrew in the hanger ball, slide the ball down the downrod , and remove the clevis pin. Then slide the hanger ball off the downrod (Figure 2). Retain all parts for reinstallation in step 11.
3. Push the wiring harness connector (supplied with the remote control) and the connector on the blue wire (supplied with the SW375 Receiver) and the uplight yellow lead assembly (supplied with the fan) through the downrod until they extend about 4" out of the downrod. (Figure 3).
4. Cut all wires approximately 3" from the end of the downrod’. Strip insulation 1/2" from end of wires.
Figure 1
Figure 2
Figure 3
IF THE CF2454 CEILING FAN IS BEING INSTALLED WITH ANY OTHER CONTROL METHOD, SKIP SECTION A AND GO TO SECTION B TO BEGIN ASSEMBLY INSTRUCTIONS.
Electrical Requirements
If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.
The Emerson CF2454 Ceiling Fan is designed to be operated from a SR330 Remote Control, from a SW350 Wall Control with a SW375 Receiver, or from other fan/light controls. There are not controls supplied with the ceiling fan. If you are going to control your ceiling fan with a SR330 Remote Control or with a SW350 Wall Control, proceed to “SECTION A”. If you are to control your ceiling fan in any other manner, proceed to “SECTION B”.
To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked acceptable for fan support, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
To avoid fire or shock, follow all wiring instructions carefully.
Any electrical work not described in these instructions should be done or approved by a licensed electrician.
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
WARNING
!
WARNING
!
WARNING
!
INSULATE BLACK WIRE USING WIRE CONNECTOR
WHITE WIRE
YELLOW WIRE
MOTOR COUPLING
3"
BLACK WIRE
BLUE WIRE
REMOVE WIRE CONNECTORS FROM RED AND BROWN WIRES
MOTOR COUPLING SLOT
CLEVIS PIN
HANGER BALL
DOWNROD
SETSCREW
WIRING HARNESS
UPLIGHT YELLOW LEAD ASSEMBLY
4"
BLUE WIRE
DOWNROD
CUT HERE
3"
9. Screw two 1-1/4” threaded studs (supplied) into the motor (Figure 6). Leave approximately 7/8” of the stud extending above the motor. Slide the motor cover over the downrod and rotate the cover until the threaded studs protrude; install two knurled knobs (supplied) to secure the cover.
NOTE: Make sure the unused black motor lead is capped with a wire connector. Make sure all wire connectors are completely inside motor coupling cover and not pinched between the motor cou­pling cover and motor.
10. Position the ceiling cover over the downrod . Be
sure the cover is oriented correctly, with the large opening at the top (Figure 7).
Figure 6
Figure 5
5
5. Using wiring connectors (supplied), connect the white, red, blue, brown, and yellow wires from the downrod to the white, red, blue, brown and yellow wires of the ceiling fan (Figure 4). Wires must be connected color-to-color.
6. Fold all wires from the downrod into the slot in the motor coupling, slide the downrod down the wires and seat the downrod in the motor coupling. All wires and wire connectors should be placed through the motor coupling slot beneath the down­rod (See Figure 5).
7. Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the clevis pin and secure with the hairpin clip. The clevis pin must go through the holes in the motor coupling and the holes in the downrod (Figure 5). Push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose.
8. Install the setscrew (supplied in the loose parts bag) in the motor coupling and tighten using the 5/32” setscrew wrench (supplied) (Figure 5).
Figure 4
It is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tight­ened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling.
WARNING
!
SW375 RECEIVER
WHITE WIRE
YELLOW WIRE TO YELLOW WIRE
BLUE WIRE TO BLUE WIRE
BLACK WIRE (NOT USED)
FAN BLADES REMOVED FOR CLARITY
RECEIVER
CONNECTOR WIRING HARNESS CONNECTOR
WHITE WIRE
DOWNROD
RED WIRE TO RED WIRE
BROWN WIRE TO BROWN WIRE
BLUE WIRE TO BLUE WIRE
WHITE WIRE TO WHITE WIRE
YELLOW WIRE TO YELLOW WIRE
LIGHT FIXTURE
BLACK WIRE
BLACK WIRE
FAN HOUSING
BLACK WIRE
120V SUPPLY
120V SUPPLY
BLACK
BLACK
WHITE WIRE
TO
WHITE
TO
LISTED GENERAL USE ON/OFF WALL SWITCH (MUST BE USED WITH SR330 REMOTE CONTROL)
SW350 WALL CONTROL
YELLOW LEADS TO BE POSITIONED IN SLOT IN MOTOR COUPLING
SETSCREW
CLEVIS PIN
HAIRPIN CLIP
CLEVIS PIN
DOWNROD
HAIRPIN CLIP
MOTOR COUPLING
DOWNROD
MOTOR COUPLING
CLEVIS PIN
KNURLED KNOB
MOTOR COUPLING COVER
WIRE CONNECTOR
YELLOW LEADS
1-1/4" THREADED STUD
7/8"
RED LEAD
BROWN LEAD
MOTOR BRACKET
WIRE CONNECTORS
Loading...
+ 11 hidden pages