Emerson CF110BS00, CF110ORB00 User Manual

Part No. F40BP74660000 Form No. BP7466 11/12 ETL Model No.: CF110
READ AND SAVE THESE INSTRUCTIONS
CALLAN
48” Ceiling Fan Owner's Manual
Model Numbers
Net Weight: 23.7 Lbs.
Questions, problems, missing parts: Before returning to the store call
Emerson Electric Customer Service
8 a.m. - 6 p.m., EST, Monday-Friday
1-800-654-3545
www.emersonfans.com
2
Safety Instructions
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a. Use this unit only in a manner intended by the
manufacturer. If you have questions, contact the manufacturer.
b. Before servicing or cleaning unit, switch power off
at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.
WARNING
!
Additional Safety Instructions for Installation
1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.
2. All wiring must be in accordance with the National Electrical Code “ANSI/NFPA 70-2011” and Local Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.
1. Read your owner’s manual carefully and keep it for future reference.
2. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.
3. Do not put anything into the fan blades while they are turning.
4. Do not operate reversing switch until fan blades have come to a complete stop.
DATE CODE:
The date code of this fan may be found on the box, stamped in ink on a white label. You should record
this data above and keep it in a safe place for future use.
ETL Model No.: CF110
READ AND SAVE THESE INSTRUCTIONS
3. The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support of 15.9kg. (35 lbs.) or less”., and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
4. The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling.
5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.
6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.
WARNING: To reduce the risk of electrical shock, this fan must be installed with an isolating wall control/switch.
NOTE: This fan is suitable for use with solid-state speed controls.
WARNING: To reduce the risk of fire or electrical shock, this fan should only be used with fan speed control, Model No. UC9020, manufactured by Rhine Electric Co., Ltd.
WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson could result in personal injury or property damage.
WARNING: To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
WARNING: To reduce the risk of electrical shock, this fan must be installed with a general use, isolating control/switch.
NOTE: All setscrews must be checked and re-tightened where necessary before installation.
Unpacking Instructions
3
emersonfans.com
Please contact 1-800-654-3545 for further assistance
ETL Model No.: CF110
This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
WARNING
!
Do not install or use fan if any part is damaged or missing. Call Toll-Free:
1-800-654-3545
WARNING
!
1. Check to see that you have received the following
parts:
NOTE: If you are uncertain of part description, refer to exploded view illustration.
NOTE: Place the parts from the loose parts bags in a small container to keep them from being lost. If any parts are missing, contact your local retailer or catalog outlet for replacement before proceeding.
2. Remove the fan assembly from the protective
plastic bag. Place the fan assembly into the upper foam pad with the bottom of the motor facing up.
The upper foam pad serves as a holder for the fan during the first stages of assembly.
PACKAGE CONTENTS
HARDWARE CONTENTS
Part Description Quantity
A Fan Motor Assembly 1
B Ceiling Canopy 1
C Coupler Cover 1
D Blade Flanges 5
E Fan Blades 5
F Hanger Bracket 1
G Hanger Ball/Downrod Assembly 1
H Upper Glass Retainer 1
I Glass Shade 1
J Lower Glass Retainer 1
K Finial 1
L SW46 Wall Control/Cover Plate 1
Part Description Quantity
1 Threaded Studs, #8-32 x 1-1/4” 2
2 Knurled Knobs, #8-32 2
3 Lockwashers, #8 2
4 Wire Connectors, Type E3 3
5 Clevis Pin 1
6 Hairpin Clip 1
7 Flange Screw (Spare), 1/4-20 x 1/2” 1
8 Washer, Paper #10 21
9 #10-32 x 5/16” Slotted Phillips Washer
Head Blade Screws 21
10 Blade Balance Kit 1
A
B
C
D
4
3
2
1
0
E
F
G
H
I
J
K
L
1
2
3
4
5
6
7
8
9
10
Before assembly your ceiling fan, refer to section on proper method of wiring your fan (page 9). If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.
WARNING
!
This Manual Is Designed to Make it as Easy as Possible for You to Assemble,
Install, Operate and Maintain Your Ceiling Fan
Tools Needed for Assembly
One Phillips head screwdriver One stepladder One 1/4” blade screwdriver One wire stripper
Materials
Wiring outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of following size:
Installed Wire Length
Wire Size A.W.G.
Up to 50 ft. 14
50-100 ft. 12
Ceiling Fan Assembly
4
ETL Model No.: CF110
Figure 1
Figure 2
Figure 3
1. Remove one of the motor housing screws and retain
for future use. Loosen the remaining three motor housing screws for assembly of the lower glass retainer (Figure 1).
2. Place the lower glass retainer onto the motor housing
and engage the key holes of the retainer onto the three motor housing screws. Rotate the lower glass retainer clockwise and tighten the three motor housing screws. Reinstall the motor housing screw (previously removed) into the remaining hole of the lower glass retainer and tighen all screws securely (Figure 2).
To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
WARNING
!
3. Mount blade flange to fan blade using four
#10-32 x 5/16” slotted Phillips washers head screws and four paper washers (Figure 3). Repeat this procedure for the remaining four blades and flanges.
MOTOR HOUSING
MOTOR HOUSING SCREWS
MOTOR HOUSING SCREWS
LOWER GLASS RETAINER
ROTATE LOWER GLASS RETAINER CLOCKWISE
#10-32 x 5/16" SLOTTED PHILIPS WASHER HEAD SCREWS (4 per blade assembly)
#10 PAPER WASHERS (4 per blade assembly)
FAN BLADE
BLADE FLANGE
5
emersonfans.com
Please contact 1-800-654-3545 for further assistance
ETL Model No.: CF110
Figure 4
Figure 5
Figure 7
Figure 6
NOTE: Take care not to scratch fan housing when installing blades.
4. Attach the flange/blade assembly to the motor hub
using the two pre-installed 1/4-20 x 1/2” flange screws and lockwashers. Make sure the screws are tightened securely (Figure 4). Repeat this procedure for the other four blade assemblies.
5. Screw the finial onto the center threaded stud of the
motor housing until securely tighten (Figure 5).
6. Carefully turn the partially assembled fan right side
up in preparation of final installation. Rest the fan motor housing onto the packing styrofoam, being careful not to bend the blades.
7. Carefully place the glass shade over the fan motor
housing, resting it into the lower glass retainer. Orintate the glass shade so that the larger lip is resting in the lower glass retainer per Figure 6.
8. Remove the four knurled retainer screws from the
motor housing and retain for future use.
9. Align the four holes of the upper glass retainer onto
the fan motor housing and reinstall the four knurled retainer screws (previously removed). Securely tighten all four screws (Figure 7).
1/4-20 x 1/2" FLANGE SCREWS WITH LOCKWASHERS PRE-ASSEMBLED (2)
MOTOR HUB
FAN MOTOR HOUSING
GLASS SHADE
FLANGE/BLADE ASSEMBLY
FINIAL
UPPER GLASS RETAINER
KNURLED RETAINER SCREW (4)
LOWER GLASS RETAINER
FAN MOTOR HOUSING
Loading...