Section 1: Introduction
1�1 General Service Information
1.1.1 This service procedure is offered as a guide to enable general maintenance to be
performed on Bettis™ CBAX30-SR spring-return series actuators. The following is
(1) Also includes actuator models with –10 and –11 as a sufx
Section 1: Introduction
August 2015
NOTE:
When the actuator model number has “-S” as a sufx then the actuator is special and may
have some differences that may not be included in this procedure.
1.1.2 Normal recommended service interval for this actuator series is ve years.
NOTE:
Storage time is counted as part of the service interval.
1.1.3 This procedure is applicable with the understanding that all electrical power and
pneumatic pressure has been removed from the actuator.
1.1.4 Remove all piping and mounted accessories that will interfere with the module(s)
that are to be worked on.
1.1.5 This procedure should only be implemented by a technically competent technician
who should take care to observe good workmanship practices.
1.1.6 Numbers in parentheses, ( ) indicate the bubble number (reference number) used
on the Bettis assembly drawing and Actuator Parts List.
1.1.7 When removing seals from seal grooves, use a commercial seal removing tool or a
small screwdriver with sharp corners rounded off.
1.1.8 Use a non-hardening thread sealant on all pipe threads.
CAUTION: FOLLOW MANUFACTURER'S INSTRUCTIONS
Apply the thread sealant per the manufacturer’s instructions.
1.1.9 Bettis recommends that disassembly of the actuator should be done in a clean
area on a workbench.
Introduction
1
Section 1: Introduction
August 2015
1�2 Definitions
WARNING:
If not observed, user incurs a high risk of severe damage to actuator and/or fatal injury to personnel.
CAUTION:
If not observed, user may incur damage to actuator and/or injury to personnel.
NOTE:
Advisory and information comments provided to assist maintenance personnel to carry out
maintenance procedures.
Service Instructions
137463E Rev. D
NOTE:
This product is only intended for use in large-scale xed installations excluded from the
scope of Directive 2011/65/EU on the restriction of the use of certain hazardous substances
in electrical and electronic equipment (RoHS 2).
M3:
Jackscrew or jackscrew assembly
M3HW:
Jackscrew assembly with handwheel
ES:
Extended Stop(s)
1�3 General Safety Information
1.3.1 Products supplied by Bettis, in its “as shipped” condition, are intrinsically safe if the
instructions contained within this Service Instruction are strictly adhered to and
executed by well trained, equipped, prepared and competent personnel.
WARNING: FOLLOW WARNING AND CAUTION SIGNS
For the protection of personnel working on Bettis actuators, this procedure should be
reviewed and implemented for safe disassembly and reassembly. Close attention should be
noted to the WARNINGS, CAUTIONS and NOTES contained in this procedure.
2
Introduction
Service Instructions
137463E Rev. D
WARNING: FOLLOW COMPANY SAFETY PROCEDURES
This procedure should not supersede or replace any customer’s plant safety or work
procedures. If a conict arises between this procedure and the customer’s procedures, the
differences should be resolved in writing between an authorized customer's representative
and an authorized Bettis representative.
1�4 Bettis Reference Materials
1.4.1 CBAX30-SR assembly drawing use part number VA129743.
1.4.2 CBBX30-SR-M3HW assembly drawing use part number 129745.
1�5 Service Support Items
1.5.1 Bettis Service Kit.
1.5.2 Commercial leak testing solution.
1.5.3 Non-hardening thread sealant.
Section 1: Introduction
August 2015
1�6 Lubrication Requirements
1.6.1 The actuator should be relubricated at the beginning of each service interval using
the following recommended lubricants.
NOTE:
Lubricants other than those listed in steps 1.6.2 should not be used without prior written
approval of Bettis Product Engineering. The lubricant item number on some assembly
drawings is item (5) while the Bettis service kits lubricant item number is item number (500).
1.6.2 All temperature services (-50°F to +350°F)/(-45.5°C to 176.6°C) use Bettis ESL-5
lubricant. ESL-5 lubricant is contained in the Bettis module service kit in tubes and
the tubes are marked ESL-4, 5 and 10 lubricant.
1�7 General Tool Information
1.7.1 All threads on CBAX30-SR series actuators are Inch Unied and NPT.
1.7.2 All tools/Hexagons are American Standard inch. Two adjustable wrenches, Allen
wrench set, small standard screwdriver with sharp edges rounded off, medium size
standard screwdriver, diagonal cutting pliers, external snap ring pliers, at le, drive
ratchet / deep well socket set and torque wrench (up to 2,000 inch pounds / 226 N-m).
(1) When model has -M3HW add 8 pounds / 3.6 kilograms.
(2) Weight is for bare actuator without accessories or valve adaption.
1�9 Actuator Storage
For applications where the actuator is not placed into immediate service, it is
recommended that the actuator be cycled with regulated clean/dry pneumatic pressure
at least once per month. Indoor storage, if available, is recommended for all actuators.
Care should be taken to plug all open ports on actuator and controls to keep out foreign
particles and moisture. Actuators should not be stored in an atmosphere that is harmful to
resilient seals. Contact factory for extended storage period.
Approximate
Weight (2)
LBKGLBKG
Actuator Model
Weight (2)
1�10 Actuator Installation
1.10.1 Since there are many valve and actuator combinations, it is not practical to include
detailed instructions for each type. Mountings are designed to be as simple as
possible to keep the guess work out of the installation.
1.10.2 Actuators that are shipped from the factory with the travel stops adjusted for
approximately ninety degree rotation. Generally, it is necessary to make slight
travel stop adjustments once the actuator is installed onto the valve. Refer to the
valve manufacturer's recommendations for specic requirements. When the valve
has internal stops, the actuator should be adjusted at the same points.
NOTE:
The actual "stopping" should be done by the actuator. If the valve does not have internal
stops, adjust the actuator to the full open position. Using this as a reference point, rotate
the valve closed and adjust to the valve manufacturer's specications for total rotation.
1.10.3 Good instrument practices are also recommended. Clean/dry regulated
pneumatic pressure is essential for long service life and satisfactory operation.
It should be noted that new pneumatic lines often have scale and other debris in
them and these lines should be purged of all foreign material.
4
Introduction
Service Instructions
137463E Rev. D
NOTE:
Scale and debris can damage control valves, solenoids and seals.
1�11 Actuator Start-up
1.11.1 Prestart-up checks
1. Inspect to ensure the unit has been mounted onto valve properly. Gear ange
mounting bolts, stem key, set screw(s) are installed and secured.
2. No tubing damaged or accessories dislodged during the shipping or the
installation.
3. Indicated position conrms valve position.
4. All switching valves in normal operating position as per
SCHEMATIC / INSTRUCTIONS.
1.11.2 Check Connections
1. Pneumatic / hydraulic components connected as per schematic enclosed or in
service manual supplied.
2. Pneumatic supply connected to the identied ports.
3. Electrical connection terminals are secured.
4. Wiring as per enclosed diagram or service manual supplied.
1.11.3 When actuator is rst placed into service, it should be cycled with regulated
pneumatic pressure. This is necessary because the seals have been stationary,
causing them to take a "set". Therefore, the actuator should be operated through
several cycles to exercise the seals so as to achieve a service ready condition.
1.11.4 The actuator speed of operation is determined by a number of factors includes:
1. Power supply line length
2. Power supply line size
3. Power supply line pressure
4. Control valve and tting orice size
5. Torque requirements of the valve
6. Size of the actuator
7. Setting of speed controls
8. Hydraulic manual override (where available)
1.11.5 Due to the interaction of these variables, it is difcult to specify a "normal"
operating time. Faster operating time may be obtained by using one or more of
the following:
1. Larger supply lines
2. Larger control valve
3. Higher supply pressure*
4. Quick exhaust valves
—* Not to exceed maximum operating pressure of actuator or
control components
1.11.6 Slower operating time may be obtained by using ow control valves to meter the
exhaust. Excessive exhaust ow metering may cause erratic operation.
Section 1: Introduction
August 2015
Introduction
5
Section 2: Actuator Disassembly
August 2015
1�12 Actuator Operation
1.12.1 Controlled Operation: Controlled operation is accomplished by pressurizing and/or
depressurizing the appropriate cylinder inlet(s) of a double-acting. Do not exceed
pressures indicated on actuator nameplate.
1.12.2 Manual Operation: All pressure must be vented or equalized on both sides of the
pneumatic piston prior to manual operation.