Emerson CBA830, CBA730-M3, CBA730-M3HW, CBA830-M3, CBA830-M3HW Disassembly And Reassembly

...
Service Instructions
137462E Rev. D
August 2015
CBAX30 Double-Acting Series Pneumatic Actuators
Disassembly and Reassembly
Service Instructions
137462E Rev. D
Section 1: Introduction
1.1 General Service Information ......................................................................... 1
1.2 Denitions ................................................................................................... 2
1.3 General Safety Information ........................................................................... 2
1.4 Bettis Reference Materials ............................................................................. 3
1.5 Service Support Items .................................................................................. 3
1.6 Lubrication Requirements ............................................................................ 3
1.7 General Tool Information .............................................................................. 3
1.8 Actuator Weight ...........................................................................................4
1.9 Actuator Storage ........................................................................................... 4
1.10 Actuator Installation ..................................................................................... 4
1.11 Actuator Start-up .......................................................................................... 5
1.12 Actuator Operation ....................................................................................... 6
Table of Contents
August 2015
Section 2: Actuator Disassembly
2.1 General Disassembly .................................................................................... 7
2.2 Pneumatic Cylinder Disassembly .................................................................. 8
2.3 Housing Disassembly ...................................................................................9
Section 3: Actuator Reassembly
3.1 General Reassembly ................................................................................... 11
3.2 Housing Reassembly ................................................................................. 12
3.3 Pneumatic Cylinder Reassembly .................................................................. 15
Section 4: Actuator Testing
4.1 Actuator Testing ......................................................................................... 19
Section 5: Field Conversions
5.1 High Temperature Service (-10 TRIM) .......................................................... 21
5.2 Low Temperature Service (-11 TRIM) ........................................................... 21
5.3 Add an Extended Stop (ES) to Housing Adapter (6-10) ................................. 21
5.4 Add an Extended Stop (ES) to Cylinder End Cap (4-20) ................................. 22
5.5 Add an M3 Jackscrew to Housing Adapter (6-10) ......................................... 23
5.6 Add an M3 Jackscrew to Cylinder Outer End Cap (4-20) ...............................24
5.7 Add M11 Override Cylinders and Pump Package.......................................... 24
Table of Contents
I
Table of Contents
August 2015
Section 6: Troubleshooting
Section 7: Removal and Decommissioning
Section 8: Document Revision ��������������������������������������������28
Appendix A: List of Tables ���������������������������������������������������29
Appendix B: List of Figures ��������������������������������������������������30
Appendix C: List of Drawings ����������������������������������������������31
Service Instructions
137462E Rev. D
6.1 Fault Insertion ............................................................................................. 25
6.2 Operational Test .......................................................................................... 26
7.1 Removal and Decommissioning .................................................................. 27
II
Table of Contents
Service Instructions
137462E Rev. D
Section 1: Introduction
1�1 General Service Information
1.1.1 This service procedure is offered as a guide to enable general maintenance to be performed on Bettis™ CBA-300 double-acting series actuators. The following is a list of general CBA-300 model numbers:
Table 1� CBA-300 Model Numbers
MODEL (1) MODEL (1) MODEL (1)
CBA730 CBA730-M3 CBA730-M3HW CBA830 CBA830-M3 CBA830-M3HW CBA930 CBA930-M3 CBA930-M3HW
CBA1030 CBA1030-M3 CBA1030-M3HW
(1) Also includes actuator models with –10 and –11 as a sufx
Section 1: Introduction
August 2015
NOTE:
When the actuator model number has “-S” as a sufx then the actuator is special and may
have some differences that may not be included in this procedure.
1.1.2 Normal recommended service interval for this actuator series is ve years.
NOTE:
Storage time is counted as part of the service interval.
1.1.3 This procedure is applicable with the understanding that all electrical power and pneumatic pressure has been removed from the actuator.
1.1.4 Remove all piping and mounted accessories that will interfere with the module(s) that are to be worked on.
1.1.5 This procedure should only be implemented by a technically competent technician who should take care to observe good workmanship practices.
1.1.6 Numbers in parentheses, ( ) indicate the bubble number (reference number) used on the Bettis Assembly Drawing and Actuator Parts List.
1.1.7 This procedure is written using the serial number tag side of the housing (1-10) as a reference and this side will be considered the front side of the actuator. The position indicator (1-50) area of housing (1-10) will be the top of the actuator.
1.1.8 When removing seals from seal grooves, use a commercial seal removing tool or a small screwdriver with sharp corners rounded off.
1.1.9 Use a non-hardening thread sealant on all pipe threads.
Introduction
1
Section 1: Introduction
August 2015
CAUTION: FOLLOW MANUFACTURER'S INSTRUCTIONS
Apply the thread sealant per the manufacturer’s instructions.
1.1.10 Bettis recommends that disassembly of the actuator should be done in a clean area on a workbench.
1�2 Definitions
WARNING:
If not observed, user incurs a high risk of severe damage to actuator and/or fatal injury to personnel.
CAUTION:
If not observed, user may incur damage to actuator and/or injury to personnel.
Service Instructions
137462E Rev. D
NOTE:
Advisory and information comments provided to assist maintenance personnel to carry out maintenance procedures.
NOTE:
This product is only intended for use in large-scale xed installations excluded from the
scope of Directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS 2).
M3:
Jackscrew or jackscrew assembly
ES:
Extended Stop(s)
1�3 General Safety Information
1.3.1 Products supplied by Bettis, in its “as shipped” condition, are intrinsically safe if the instructions contained within this Service Instruction are strictly adhered to and executed by well trained, equipped, prepared and competent personnel.
WARNING: FOLLOW WARNING AND CAUTION SIGNS
For the protection of personnel working on Bettis actuators, this procedure should be reviewed and implemented for safe disassembly and reassembly. Close attention should be noted to the WARNINGS, CAUTIONS and NOTES contained in this procedure.
2
Introduction
Service Instructions
137462E Rev. D
WARNING: FOLLOW COMPANY SAFETY PROCEDURES
This procedure should not supersede or replace any customer’s plant safety or work
procedures. If a conict arises between this procedure and the customer’s procedures, the
differences should be resolved in writing between an authorized customer's representative and an authorized Bettis representative.
1�4 Bettis Reference Materials
1.4.1 CBA-300 assembly drawing use part number 129742.
1.4.2 CBA-300-M3HW assembly drawing use part number 129744.
1�5 Service Support Items
1.5.1 Bettis Service Kit.
1.5.2 Commercial leak testing solution.
1.5.3 Non-hardening thread sealant.
Section 1: Introduction
August 2015
1�6 Lubrication Requirements
1.6.1 The actuator should be relubricated at the beginning of each service interval using the following recommended lubricants.
NOTE:
Lubricants other than those listed in steps 1.6.2 should not be used without prior written approval of Bettis Product Engineering.
1.6.2 All temperature services (-50°F to +350°F)/(-45.5°C to 176.6°C) use Bettis ESL-5 lubricant. ESL-5 lubricant is contained in the Bettis module service kit in tubes and the tubes are marked ESL-4, 5 and 10 lubricant.
1�7 General Tool Information
1.7.1 All threads on CBA series actuators are Inch Unied and NPT.
1.7.2 All tools/Hexagons are American Standard inch.
1.7.3 Suggested tools: Two adjustable wrenches, small standard screwdriver with sharp edges rounded off, medium size standard screwdriver, external snap ring pliers, drive ratchet / deep well socket set and torque wrench (up to 3,000 inch pounds / 339 N-m).
Introduction
3
Section 1: Introduction
August 2015
1�8 Actuator Weight
Table 2� Actuator Weight
Service Instructions
137462E Rev. D
Actuator
Model
CBA730 130 59 CBA930 155 70.4
CBA730-M3 131 59.4 CBA930-M3 158 71.7
CBA730-
M3HW
CBA830 140 63.5 CBA1030 170 77.1
CBA830-M3 143 64.9 CBA1030-M3 173 78.5
CBA830-
M3HW
(2) Weight is for bare actuator without accessories or valve adaptation.
Approximate Weight (2)
LB KG LB KG
131.5 59.6
143.5 65.1
1�9 Actuator Storage
For applications where the actuator is not placed into immediate service, it is recommended that the actuator be cycled with regulated clean/dry pneumatic pressure at least once per month. Indoor storage, if available, is recommended for all actuators. Care should be taken to plug all open ports on actuator and controls to keep out foreign particles and moisture. Actuators should not be stored in an atmosphere that is harmful to resilient seals. Contact factory for extended storage period.
1�10 Actuator Installation
Actuator
Model
CBA930-
M3HW
CBA1030-
M3HW
Approximate Weight (2)
158.5 71.9
173.5 78.7
1.10.1 Since there are many valve and actuator combinations, it is not practical to include detailed instructions for each type. Mountings are designed to be as simple as possible to keep the guess work out of the installation.
1.10.2 Actuators that are shipped from the factory with the travel stops adjusted for approximately ninety-degree rotation. Generally, it is necessary to make slight travel stop adjustments once the actuator is installed onto the valve. Refer to the
valve manufacturer's recommendations for specic requirements. When the valve
has internal stops, the actuator should be adjusted at the same points.
NOTE:
The actual "stopping" should be done by the actuator. If the valve does not have internal stops, adjust the actuator to the full open position. Using this as a reference point, rotate
the valve closed and adjust to the valve manufacturer's specications for total rotation.
4
Introduction
Service Instructions
137462E Rev. D
1.10.3 Good instrument practices are also recommended. Clean/dry regulated pneumatic pressure is essential for long service life and satisfactory operation. It should be noted that new pneumatic lines often have scale and other debris in them and these lines should be purged of all foreign material.
NOTE:
Scale and debris can damage control valves, solenoids and seals.
1�11 Actuator Start-up
1.11.1 Prestart-up checks
1. Inspect to ensure the unit has been mounted onto valve properly. Gear
ange mounting bolts, stem key, set screw(s) are installed and secured.
2. No tubing damaged or accessories dislodged during the shipping or the installation.
3. Indicated position conrms valve position.
4. All switching valves in normal operating position as per SCHEMATIC / INSTRUCTIONS.
1.11.2 Check connections
1. Pneumatic / hydraulic components connected as per schematic enclosed or in service manual supplied.
2. Pneumatic supply connected to the identied ports.
3. Electrical connection terminals are secured.
4. Wiring as per enclosed diagram or service manual supplied.
1.11.3 When actuator is rst placed into service, it should be cycled with regulated pneumatic pressure. This is necessary because the seals have been stationary, causing them to take a "set". Therefore, the actuator should be operated through several cycles to exercise the seals so as to achieve a service ready condition.
1.11.4 The actuator speed of operation is determined by a number of factors includes:
1. Power supply line length
2. Power supply line size
3. Power supply line pressure
4. Control valve and tting orice size
5. Torque requirements of the valve
6. Size of the actuator
7. Setting of speed controls
8. Hydraulic Manual Override (where available)
Section 1: Introduction
August 2015
Introduction
5
Section 1: Introduction
August 2015
1.11.5 Due to the interaction of these variables, it is difcult to specify a "normal" operating time. Faster operating time may be obtained by using one or more of the following:
1. Larger supply lines
2. Larger control valve
3. Higher supply pressure *
4. Quick exhaust valves
* Not to exceed maximum operating pressure of actuator or
control components
1.11.6 Slower operating time may be obtained by using ow control valves to meter the
exhaust. Excessive exhaust ow metering may cause erratic operation.
1�12 Actuator Operation
1.12.1 Controlled Operation: Controlled operation is accomplished by pressurizing and/ or depressurizing the appropriate cylinder inlet(s) of a double-acting. Do not exceed pressures indicated on actuator nameplate.
1.12.2 Manual Operation: All pressure must be vented or equalized on both sides of the pneumatic piston prior to manual operation.
Service Instructions
137462E Rev. D
6
Introduction
Service Instructions
137462E Rev. D
Section 2: Actuator Disassembly
Section 2: Actuator Disassembly
2�1 General Disassembly
WARNING: DANGEROUS GAS AND/OR LIQUIDS
It is possible, that the actuator may contain a dangerous gas and/or liquids. Ensure that all proper measures have been taken to prevent exposure or release of these types of contaminants before commencing any work.
CAUTION: DO NOT EXCEED OPERATING PRESSURE
Pressure applied to the actuator is not to exceed the maximum operating pressure rating listed on the actuator name tag.
August 2015
NOTE:
Before starting the general disassembly of the actuator, it is a good practice to operate actuator with the pressure used by the customer during normal operation. Notate and record any abnormal symptoms such as jerky or erratic operation.
2.1.1 Remove all operating pressure from actuator.
NOTE:
In place of stop screws, the actuator may be equipped with one or two ES (ES = Extended Stops) or M3/M3HW located on outboard end of housing (1-10) and end cap (4-20).
2.1.2 Record the settings of stop screw, ES or M3 jackscrews (6-30) and (4-30) before they are loosened or removed.
2.1.3 To help in correct reassembly, all mating parts should be marked or tagged for ease of reassembly, i.e. cylinder to cylinder adapter, cylinder adapter to housing, housing to torque shaft and housing to housing adapter, etc.
Actuator Disassembly
7
Section 2: Actuator Disassembly
August 2015
2�2 Pneumatic Cylinder Disassembly
NOTE:
Review Section 2 steps 2.1.1 through 2.1.3 before proceeding with cylinder disassembly.
2.2.1 Remove hex nut (4-40) as follows: CBA730 through CBA1030 standard end cap stop screw or extended stop (ES), use step 2.2.1.1. CBA730 through CBA1030 with
-M3 or -M3HW use step 2.2.1.2.
2.2.1.1 CBA730 through CBA1030 end cap stop screw or extended stop screw
(ES)
2.2.1.1.1 Loosen and remove hex nut (4-40) and washer (4-90) from stop screw (4-30) located in end cap (4-20).
2.2.1.1.2 Remove stop screw (4-30) from the end cap (4-20).
2.2.1.2 CBA730 through CBA1030-M3 or -M3HW
2.2.1.2.1 Remove retainer ring (12-30) and groove pin (12-20) from optional hex drive hub or from hand wheel (12-10).
2.2.1.2.2 Remove optional hex drive hub or hand wheel (12-10) from M3 jackscrew (4-30).
2.2.1.2.3 Remove caution tag (12-40) from M3 jackscrew (4-30).
2.2.1.2.4 Loosen and remove hex nut (4-40) from M3 jackscrew (4-30).
Service Instructions
137462E Rev. D
NOTE:
For CBA730 through CBA1030-M3 or M3HW models, the M3 jackscrew (4-30) cannot be removed now. The M3 used in these models can be removed later in this procedure using step 2.2.7.
2.2.2 Remove housing side hex nut (8-20) from center bar (8-10).
2.2.3 Remove outer end cap (4-20) from outboard end of cylinder (4-10).
NOTE:
ES (4-30) or stop screw (4-30) does not require removal from end cap (4-20) unless replacing with a new ES or stop screw.
2.2.4 Slide cylinder (4-10) over piston (4-50) and remove.
2.2.5 Remove piston (4-50) from center bar (8-10).
NOTE:
The standard non-M3 piston (4-50) is an assembly made up of one roll pin and one yoke pin; do not attempt to disassemble the piston assembly. The M3 piston (4-50) has two targets and four drive screws in addition to the roll pin and yoke pin.