Emerson Avtron LSV Brochures and Data Sheets

Avtron LSV
Resistive Permanent Load Bank - 3000 to 4600 KW
Testing Your Emergency Standby Generator with a Load Bank Means Reliability When it Matters Most.
Key Features
• High Capacity per Module
• -0+5% Overall Load Tolerance
• Reduced Installation Costs
• Vertical Air Discharge
• 5 KW Direct Connect version available (2000 KW max)
• PLC or Computer Based Controls are also available
Superior Avtron quality combined with simple operation and maintenance will provide years of trouble free service.
Avtron’s extensive line of Load Bank and Industrial Resis tor Products are solid performers used throughout the world.
The Avtron Model LSV Load Bank is used for testing high capacity power sources.
The Avtron LSV resistive load bank is ideal for testing high capacity generators or turbines. Avtron is leading the industry by offering a high capacity load bank. This load bank is ideal for permanent outdoor installation for routine load testing of standby diesel generating systems or for factory production line testing of (UPS) Uninterruptible Power Supplies, turbines, or en­gine generator sets.
The LSV load bank is designed for permanent outdoor installation which features vertical air discharge for installation in areas where space is at a premium such as the rooftops of high-rise buildings. Weatherproof exhaust hoods provide maximum protection to the resistor cases and blower assemblies.
Each load bank module is typically rated between 3 and 4.6 MW. Multiple modules are used when tens or hundreds of megawatts are required. Voltages from 400 thru 600 VAC are available.
The LSV load bank incorporates 4, 6, or 8 independent resistive stacks. Each resistive stack contains its own integral cooling fan. A hinged and lockable compartment houses the main input load bus connections as well as load step contactors. The operator controls are housed in a separate remote enclosure. The LSV features the latest load bank design and manufacturing techniques to provide years of trouble-free service. Our commitment to customer satisfaction assures quick delivery, easy installation, and simple operation and maintenance.
This load bank is ideal for high power resistive loading of generating systems in factory production lines or test cells. It is designed for permanent outdoor mounting.
For total technical support or additional information, please contact Avtron at (216) 573-7600 or LBsales@Emerson.com.
Quality System Certified to ISO 9001
LSV 3000 KW Permanent Resistive Avtron Load Bank.
Avtron LSV
Resistive Permanent Load Bank - 3000 to 4600 KW
Specications subject to change without notice.
Construction
The load bank is fabricated from heavy gauge formed steel and welded structural steel, making a rigid, drip-proof structure suitable for permanent outdoor mounting. Cooling air for the resistive load elements is drawn in from the bottom and exhausted out the top. Weather-resistant exhaust hoods and welded intake screens provide maximum protection to the resistor cases and blower assemblies. Structural extension legs are provided for mounting the load bank at the proper field elevation.
Resistor Elements
Avtron Helidyne™ load elements are helically wound from nickel chromium resistance alloy and are specially designed for high power applications. The elements are fully supported across their entire length with ceramic insula­tors on stainless steel support rods.
Control Power
The LSV requires control power of 120 VAC, single phase, 60 Hz power (control trans­former optional).
Cooling
The resistive load elements are air cooled by multiple integrally mounted blower motors. The blower motors are controlled by motor starter relays located within the load bank and feature a time delay starting sequence to reduce in-rush current. An external power source rated 460 VAC, 3 phase, 60 Hz is re­quired to power the blowers. Motors rated 575 VAC, 60 Hz, 415 VAC, 50 Hz, or 380 VAC, 50 Hz are available as options.
Manual Controls
A rack-mounted control panel is provided for remote mounting. Controls include POWER ON-OFF switch, a POWER ON light, BLOWER ON-OFF push buttons with a BLOWER FAILURE light, OVERTEMPERATURE light, MASTER LOAD ON-OFF switch, and individual load step ON-OFF toggle switches which actuate the load contactors located within the load bank.
Protection
Differential air pressure switches are provided for each blower. Overtemperature protection is provided via a thermal switch for each resis­tor stack. Should an air-loss or overtempera­ture condition occur, all load is automatically removed. Fuses and motor-overload relays also protect the blowers.
Options
• SIGMA™ Network Control
• Low dB Versions
HINGED, LOCKABLE FRONT ACCESS PANELS
112.50 [2857]
100.00 [2540]
141.00 [3581]
102.00 [2591]
94.81
[2408]
ø1.250 [32.0] FRAME MOUNTING HOLES
MAIN LOAD BANK INPUT CONNECTION
19.00 [483] TYP
16.94 [430] TYP
Load Capacity Ratings
Load Step Resolution is 50 KW. Bulk load also available.
Total Load Voltage
3-4.6 MW 400, 480, 600
Load Bank Weight (approx.)
3000 to 4600 KW: 9600 lbs. [4354 kg]
BOLT ON ALUMINIZED STEEL (UNPAINTED) EXHAUST HOODS
WELDED ON OVERHEAD LIFTING CLEATS
MANUAL LOCAL CONTROL NEMA 4
88.00
[2235]
All dimensions are in inches [millimeters].
BOLT ON ACCESS PANELS
166.25 [4223]
154.25 [3918]
BOTTOM VIEW
Emerson Network Power
Avtron 6255 Halle Drive, Cleveland, Ohio 44125, U.S.A.
216-573-7600 • FAX: 216-573-5953 • LBsales@Emerson.com
EmersonNetworkPower.com/loadbank
Emerson. Consider it Solved and Emerson Network Power are trademarks of Emerson Electric Co.
or one of its afliated companies. All the other marks are the property of their respective owners.
Helidyne™ is a trademark of Avtron. SIGMA™ is a trademark of NJ Froment & Co. Ltd.
Specications subject to change without notice.
©2015 Emerson Network Power Bulletin 601• Rev. A