Avtron LCV
Resistive/Reactive Load Bank - 3125 to 6250 KVA
Testing Your Emergency Standby
Generator with a Load Bank Means
Reliability When it Matters Most.
Key Features
• Highest Capacity in the Industry
• Provides Resistive and Reactive
Loading
• Rugged ISO Style Container
• PLC Based Load Control
• Local and Remote Load Control
• Easy Interconnection and
Operation
Superior Avtron quality combined with
simple operation and maintenance will
provide years of trouble free service.
Avtron’s extensive line of Load Bank and
Industrial Resis tor Products are solid
performers used throughout the world.
The Avtron Model LCV Load Bank is used for high power
resistive/reactive testing of AC generating systems.
The Avtron LCV load bank is designed to provide high capacity resistive and reactive loading
of AC power systems such as diesel generator sets, turbines, or Uninterruptible Power Supplies
(UPS). Many specifications and local codes demand that such testing be performed at less
than unity power factor, typically 0.8 p.f. lagging. The LCV load bank is ideal for high power
resistive and reactive testing of AC generating systems in factory production lines or in the
field after installation.
The LCV load bank combines resistive load (KW) with reactive load (KVAR) to achieve a 0.8 p.f.
This combination provides a true test of the actual generator or UPS nameplate rating (KVA)
and simulates a “real-world” load.
The LCV incorporates state-of-the-art load bank design features with the highest capacity in
the industry (20' [6096] container). The resistor elements, iron-core reactors, blowers, and
controls are all manufactured from the highest quality components available.
For total technical support or additional
information, please contact Avtron at
(216) 573-7600 or LBsales@Emerson.com.
Quality System Certified to ISO 9001
LCV 3750 KVA Resistive/
Reactive Avtron Load Bank.
Avtron LCV
LOAD CONNECTION
COMPARTMENT
Resistive/Reactive Load Bank - 3125 to 6250 KVA
Specications subject to change without notice.
Construction
The load bank consists of a rugged ISO style
container housing the resistive and reactive
components, blowers, associated controls,
and interconnections. The container features
air intakes on the sides of the container with
vertical exhaust through the roof.
Resistor Elements
The resistive elements are manufactured of a
corrosion resistant chromium alloy wire and
are fully supported with stainless steel rods for
long life.
Reactive Elements
The reactive elements are of non-saturating
single and 3 phase iron-core construction
impregnated with high dielectric varnish.
Control Power
120 VAC, single phase, 60 Hz provided by an
integral control transformer.
Metering
Digital metering with data logging is
provided to measure voltage, current,
frequency, KW, KVAR, and power factor.
Cooling
The resistive elements are cooled by integrally mounted blower motors each rated
10 HP, 460 VAC, 3 phase, 60 Hz.
Controls
The LCV load bank features both local and
remote load control. The remote hand held
controller is rugged and compact (7"x 7"x 2").
The controller is easy to operate and load
values are activated by pressing a membrane
style keypad. All resistive and reactive functions are displayed on a LCD display. A hard
wired E-stop push button is also provided.
The remote controller communicates with
the Load Bank PLC via 200' of control cable in
(2) 100' increments with MS style connectors.
Protection
This load bank features branch circuit fusing
on all load steps and overtemperature protection. Air switches on the blowers are electrically interlocked to remove load if the airflow
is not sufficient to provide proper cooling.
Emerson Network Power
Avtron • 6255 Halle Drive, Cleveland, Ohio 44125, U.S.A.
216-573-7600 • FAX: 216-573-5953 • LBsales@Emerson.com
EmersonNetworkPower.com/loadbank
Typical Capacity Ratings
Available Load Step Resolution: 25KW, 18.75 KVAR
Total Load
KVA at
0.8 p.f.
NOTE Standard voltage is 480 VAC, 3 phase, 60 Hz. Other
voltages and frequencies are available. Consult factory.
Resistive
Load KW
3125 2500 1875
3750 3000 2250
5000 4000 3000
6250 5000 3750
Reactive
Load KVAR
Load Bank Weight (approx.)
3125 or 3750 KVA: 28,600 lbs. [13,000 kg]
5000 KVA: 32,700 lbs. [14,800 kg]
6250 KVA: 36,300 lbs. [16,500 kg]
Options
• SIGMA™ Network Control
• Heavy Duty Dual Axle Trailer
COMPARTMENT
BOLTED & HINGED
ENTRY DOOR FOR
SERVICE/ACCESS
VERTICAL EXHAUST AIR VERTICAL EXHAUST AIR
Emerson. Consider it Solved and Emerson Network Power are trademarks of Emerson Electric Co.
or one of its afliated companies. All the other marks are the property of their respective owners.
Communicator EXT™ is a trademark of Electro Industries/GaugeTech. ADMS™ is a trademark of Avtron.
SIGMA™ is a trademark of NJ Froment & Co. Ltd. Specications subject to change without notice.
©2015 Emerson Network Power Bulletin 432• Rev. D
238.50 [6058.00]
• Cable Reels
CONTROL
96.00 [2438.00]
17.00 MAX
[432.00]
102.00
[2591.00]
EXHAUST HATCHES
(MAY BE REMOVED
FOR SHIPPING)
BOLT-ON
ACCESS PANELS
EXTERNAL BLOWER
CONTROL POWER
CONNECTION BOX
AIR INTAKE
(TYPICAL)
FORKLIFT POCKETS
All dimensions are in inches [millimeters].