36G-36J Series
Electronic Ignition
Gas Valves
80% of furnaces made in the past
15 years can be serviced with six
36J Gas Valve models
Trusted by more OEMs
White-Rodgers is the largest gas valve
manufacturer in North America
More OEMs use White-Rodgers than any
other brand
Ease of Installation
Quick connect spade terminals
Most models include LP conversion kit
Reducer bushing kit included on most
models
DID YOU KNOW?
36J series gas valves
replace over 500 models.
FEATURES:
• Convertible - natural or LP gas
• Adjustable regulator(s)
• Inlet/outlet screens
• Built-in pressure taps
• Electric on-off switch
• Quick connect spade terminals
• Tamper resistant screws and controlled
gasket compression to withstand high
inlet pressures
SWITCH
2.750
SWING
RADIUS
(SWITCHED IN ”ON” POSITION)
SPECIFICATIONS:
Electrical Rating
.28 Amps (Single Stage)
.43 Amps (Two-Stage)
Operating Voltage
24 Vac 50/60 Hz
Temperature Operating Range
-40° to 175° F (-40° to 79° C)
Maximum Pressure Rating
1/2” PSI 14.0” WC
Inlet & Outlet Pressure Taps
1/8 ” NP T
Mounting
Multipoise
Agency Approvals
CSA
2.781
0.500
4.243
1.250
1.329
36G/36J
Valve
(Stages)
Single 1/2” x 1/2” 140,000 226,800 20,000-210,000 65,000-340,000
Two 1/2” x 1/2” 140,000 226,800 20,000-210,000 65,000-340,000
Modulating 1/2” x 1/2” 140,000 226,800 40,000-210,000 65,600-340,000
Voltage
24 Vac
50/60Hz
24 Vac
50/60Hz
24 Vac
50/60Hz
24 Vac
50/60Hz
24 Vac
50/60Hz
24 Vac
50/60Hz
24 Vac
50/60Hz
24 Vac
50/60Hz
24 Vac
50/60Hz
24 Vac
50/60Hz
* To measure outlet pressure on valves, loosen outlet pressure tap screw one quarter turn and put manometer hose over the top of the outlet pressure tap.
** Use F92-0659 to convert to regulated L.P. gas
Not for Standing Pilot
INLET - 1/2” N.P.T.
(PLASTIC DUST PLUG INSTALLED)
1” Pressure Drop Capacity Range of Regulation
BTU/HR BTU/HR
Pipe
Size
Stages /
Opening
1 - Stage
Fast Open
1 - Stage
Fast Open
1 - Stage
Slow Open
1 - Stage
Fast Open
1 - Stage
Slow Open
Modulating 1/2” X 1/2” 3.5” 0.4”-4.0” 1.3”-11.5” Yes Yes Str. Thru Yes / Yes Yes No No 36J27-554 36J27-554
2 - Stage
Fast Open
2 - Stage
Slow Open
1 - Stage
Slow Open
2 - Stage
Slow Open
Pipe
Size
1/2” X 1/2” 3.5” 2.5”-5.0” 7.0”-12.0” No** No Str. Thru Yes / Yes* Yes No No 36G22-254 36G22-254
1/2” X 1/2” 3.5” 2.5”-5.0” 7.0”-12.0” Yes No Str. Thru
1/2” X 1/2” 3.5” 2.5”-5.0” 7.0”-12.0” Yes No Str. Thru
1/2” X 1/2” 3.5” 2.5”-5.0” 7.0”-12.0” Yes Yes Str. Thru Yes / Yes Yes No No 36J22-214 36J22-214
1/2” X 1/2” 3.5” 2.5”-5.0” 7.0”-12.0” Yes Yes Str. Thru Yes / Yes Yes No No 36J24-214 36J24-214
1/2” X 1/2”
1/2” X 1/2”
1/2” X 1/2” 3.5” 2.5”-5.0” 7.0”-12.0” Yes No
1/2” X 1/2”
Std. Gas
.64 Sp. Gr.
(1000 Btu/ft3)
Regulator
Setting
1.5” Low
3.5” High
1.5” Low
3.5” High
1.5” Low
3.5” High
Natural Gas Adj.
LP Gas
1.53 Sp. Gr.
(2500 Btu/ft3)
Range (WC)
1.0”-4.0” Low
2.0”-5.0” High
1.0”-4.0” Low
2.0”-5.0” High
1.0”-4.0” Low
2.0”-5.0” High
36J
Std Gas
.64 Sp. Gr.
(1000 Btu/ft3)
Lp Gas Adj.
Range (WC)
4.0”-10.0” Low
6.0”-12.0” High
4.0”-10.0” Low
6.0”-12.0” High
4.0”-10.0” Low
6.0”-12.0” High
4.693
ALL DIME NSIONS
IN INCHES
LP Gas
1.53 Sp. Gr.
(2500 Btu/ft3)
Reducer
LP Kit
Bushing
Incl.
Yes Yes Str. Thru Yes / Yes* Yes No No 36J54-214 36J54-214
Yes Yes Str. Thru Yes / Yes* Yes No No 36J55-214 36J55-214
Yes No
Kit
Flow
Direction
90° Bottom
Outlet
90° Bottom
Outlet
Inlet / Outlet
Pressure Tap
Yes / Yes*
NPT & Towers
Yes / Yes*
NPT & Towers
Yes / Yes* Ye s No No 36J24-614 36J24-614
Yes / Yes* Ye s No No 36J55-614 36J55-614
Answers at your ngertips, with your
.542
.648
.828
36G
3.960
MOUNTING HOLES (2)
FOR #8-32 TH READ FORM ING SCREW S
1.339
WR MOBILE APP
smartphone or tablet.
Intermittent
HSI
/ Proven
/ DSI
Pilot
Yes Ye s Yes 36G32-500 36G32-500
Yes Ye s Yes 36G33-500 36G33-500
Flange
Mount
Capable
Model
Number
Item
Number
R-4861-2 (1/21) ©2021 Emerson Ele ctric Co. | W hite-Rod gers and Eme rson are tra demarks of E merson El ectric Co. A ll rights re served | Customer Ser vice or Technical Help: 888-725-9797 | Emerson.com/White-Rodgers