Fig. 1 – OVL-II ER Fig. 2 – OVL-II SR Fig. 3 – OVL-II SER Fig. 4 – OVL-II ESR
Figure
1
2
3
4
Model
OVL-II ER
OVL-II SR
OVL-II SER
OVL-II ESR
Description
OVL-II Series - Extended Reach
OVL-II Series - Standard Reach
OVL-II Series - Dual Installation
OVL-II Series - Dual Installation
INSTALLER
Review these instructions before beginning installation. Be sure that installation
conforms to all plumbing, electrical and other applicable codes.
When installation is complete, ensure these instructions are left in the plastic bag
provided inside the installed unit for future reference.
Service to be performed by authorized service personnel only.
NOTE: It is common practice to ground electrical hardware such as telephones, computers and other devices to
available water lines. This can, however, cause electrical feedback in the plumbing circuit, which results in an
“electrolysis” effect occurring in the fountain. This may result in water which has a metallic taste to it or has a
noticeable increase in the metallic content of the water.
When inspecting plumbing circuit, remember the line may be grounded some distance from the installation, and
may occur outside the building or area in which the unit is being installed.
This condition can be avoided (in most cases) by using recommended materials during installation. Any drain
ttings provided by the installer should be made of plastic which will electronically isolate the fountain from the
remainder of the building’s plumbing circuits.
Page 1
97881C - (Rev. L- 07/16)
OVLERQ*D OVLSRQ*D OVLESRQ*G OVLSERQ*G
1/4” O.D. TUBE
WATER INLET
TO COOLER
NOTE: WATER FLOW
3/8” O.D. UNPLATED COP-
PER TUBE CONNECT
COLD WATER SUPPLY
DIRECTION
SERVICE STOP
(NOT FURNISHED)
Figure 5 – Water Supply Connections
Parts List
ItemPart No.Description
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
26990C
26988C
55836C
55991C
51546C
45396C
98481C
1000001791
1000002705
160270508640
45400C
101570540560
51575C
110346220550
101637451550
161637308640
45398C
45683C
45682C
100023340560
161570808550
61314C
1000002145
27006C
27342C
27000C
27344C
70861C
55840C
55839C
27338U
27338C
27340U
27340C
28328C
97881C - (Rev. L - 07/16)
Bottom Cover - Standard Reach
Bottom Cover - Extended Reach
Push Arm Actuator Plate
Push Arm Actuator Plate - A.G.
Bubbler
Bubbler - A.G.
Bubbler - EasyFlex (option)
Kit - VR Bubbler-Smart Flow ™
Kit - VR Bubbler Nipple/Gaskets
Kit - Bubbler Nipple/Gaskets
Strainer Plate - S.S.
Strainer Plate - A.G.
Drain Gasket
Packing Ring
Drain Nut
Friction Ring
Drain Plug - S.S.
Drain Plug - A.G.
Drain Tube
Drain Tube
Waste Tube Gasket
Slip Nut
Regulator
Kit - Regulator Holder (5 Pack)
Basin - S.S.
Basin - A.G.
Basin - Galaxy Gray Marblyte (option)
Basin - Golden Sand Marblyte (option)
Basin - Black Onyx Marblyte (option)
Basin Liner - S.S.
Basin Liner - A.G.
Screw - #10-24 X 2.00
Top Plate - Actuator
Bottom Plate - Actuator
Extended Reach Arm - S.S.
Extended Reach Arm - A.G.
Standard Reach Arm - S.S.
Standard Reach Arm - A.G.
Regulator Mounting Bracket
BUILDING WATER
INLET
OVL-II ER
Page 2
Installation Package
The components for installation are packed in three
separate boxes, regardless of the type of unit being
installed. The boxes contain the following:
Additional materials, as noted in the Parts List, are also
shipped in these boxes.
Number Required
See
Fig.
27
27
23
23
27
27
-
26
26
26
27
23
27
27
27
27
27
27
27
27
27
27
25
25
23,26,26
27
-
-
-
27
27
27
23
23
27
27
27
27
24
-
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
-
1
1
1
1
1
1
1
1
1
1
1
4
1
1
1
1
-
-
1
OVL-II SR
1
-
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
-
1
1
1
1
1
1
1
1
1
1
1
1
4
1
1
-
-
1
1
1
OVL-II SER
1
1
2
2
2
2
2
2
2
2
2
2
2
2
4
2
2
2
1
1
2
2
2
2
2
2
2
2
2
2
2
8
2
2
1
1
1
1
2
OVL-II ESR
1
1
2
2
2
2
2
2
2
2
2
2
2
2
4
2
2
2
1
1
2
2
2
2
2
2
2
2
2
2
2
8
2
2
1
1
1
1
2
OVLERQ*D OVLSRQ*D OVLESRQ*G OVLSERQ*G
ItemPart No.Description
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
1000002027
1000001926
27008C
70856C
70854C
50198C
0000001323
28327C
28326C
22797C
27886C
22799C
27888C
26958C
27890C
22795C
27892C
1000003515
1000003517
1000003518
26833C
27894C
27026C
27896C
55996C
1000002162
1000001994
56092C
Kit - Nut-Retaining (5 Pack)
Kit - Hex Nut-Unplated (4 Pack)
Reaction Bracket
Screw - #10-24 x .38 PHMS
Rod - Pivot
Bushing Snap
Kit - Pivot Bracket/Bushing/Bumper/Rod
Arm - Regulator Activating
Arm - Regulator Adjustment
Upper Panel (OVL-II ER) - S.S.
Upper Panel (OVL-II ER) - A.G.
Upper Panel (OVL-II SR) - S.S.
Upper Panel (OVL-II SR) - A.G.
Upper Panel (OVL-II SER) - S.S.
Upper Panel (OVL-II SER) - A.G.
Upper Panel (OVL-II ESR) - S.S.
Upper Panel (OVL-II ESR) - A.G.
Upper Panel (OVL-II ER-GRN) S.S.
Upper Panel (OVL-II SER-GRN) S.S.
Upper Panel (OVL-II ESR-GRN) S.S.
Lower Panel (OVL-II ER/SR) - S.S.
Lower Panel (OVL-II ER/SR) - A.G.
Lower Panel (OVL-II SER/ESR) - S.S.
Lower Panel (OVL-II SER/ESR) - A.G.
Strainer (Supplied with Chiller)
Kit - Union-1/4” (3 Pack)
Kit - Tee-1/4” (3 Pack)
Poly Tubing - 1/4” (Cut To Length)
Parts List Continued
OVL-II ER OVL-II SR
1
1
1
1
1
4
1
1
1
1
1
-
-
-
-
-
-
1
-
-
1
1
-
-
1
1
-
1
1
1
1
1
1
4
1
1
1
-
-
1
1
-
-
-
-
-
-
-
1
1
-
-
1
1
-
1
OVL-II SER
2
2
2
2
2
8
2
2
2
-
-
-
-
1
1
-
-
-
1
-
-
-
1
1
1
1 If Filtered
1
1
OVL-II ESR
2
2
2
2
2
8
2
2
2
-
-
-
-
-
-
1
1
-
-
1
-
-
1
1
1
1 If Filtered
1
1
See
Fig.
NS = Not Shown
NOTE: S.S. means Stainless Steel
A.G. means Aztec Gold
N-S means not shown
Page 3
97881C - (Rev. L- 07/16)
OVLERQ*D OVLSRQ*D OVLESRQ*G OVLSERQ*G
Note: Danger! Electric shock hazard. Disconnect power before servicing unit.
Uses HFC-134A refrigerant
Models
OVL-II SER – OVL-II ESR
1. Cut a rectangular wall opening 37-1/2” (953 mm) W
x 37-3/4” H (959 mm) and 4-1/2” (114 mm) above the
oor line (see Figure 7). The dimensions are required
to obtain proper rim and bubbler heights for compliance
with ANSI standard A117.1.
2. Reinforce the wall opening on all sides to adequately
support the water fountain. This reinforcement must
support up to 150 lbs. W load and provide a means for
securing the frame assembly in place.
NOTE: Building construction must allow for adequate
air ow on both sides and top of remote chiller
unit a minimum of 4” (102 mm) is required.
3. Install plumbing and electrical rough-ins. A junction
box for a (3) wire, 10 amp branch circuit is provided
on the inside of the chiller. (Standard 120 Volts, 60 Hz,
and single phase.)
Figure 6 – OVL-II SER Rough-In
REVERSED CONFIGURATION:
HIGHER UNIT ON THE RIGHT
4. Remove frames and related hardware from
packaging. Release the two shelf rods by cutting cable
ties. Attach the two frames together through the upright
supports with (4) 5/16” x 3/4” (19 mm) long bolts and
nuts (provided). Tighten securely.
MAKE SURE FRAME CONFIGURATION
MATCHES THE COOLER TO BE INSTALLED
STANDARD CONFIGURATION:
HIGHER UNIT ON THE LEFT
97881C - (Rev. L - 07/16)
Figure 7 – Rough-In Assembly
Dual-Station Mounting Frames
Page 4