Installation Instructions
HCR8-1J Refrigeration Packages
NOTICE: This water cooler must be connected to the water supply using a dielectric coupling.
IMPORTANT! INSTALLER PLEASE NOTE.
The grounding of electrical equipment such as telephone, computers, etc., to water lines is a common procedure. This ground­ing may be in the building, or may occur away from the building. This grounding can cause electrical feedback into a water chiller, creating an electrolysis which causes a metallic taste or an increase in the metal content of the water. This condition is avoidable by using the proper materials indicated below.
INST ALLATION
1. When mounting unit in an open area, to insure proper ventilation, maintain a 4" (102mm) clearance from cabinet louvers on each side of cooler . When mounting unit in a cavity or behind a wall maintain minimum space of 4" (102mm) on each side, 4" (102mm) on the top and a depth of 12" (305mm).
3. Connecting lines to be of unplated copper, thoroughly flushed to remove all foreign matter before being connected to cooler. If flushing does not remove all particles, a water strainer should be installed in supply line. This cooler is manufactured in such a manner that it does not in any way cause taste, odor, color or sediment problems.
4. Connect cooler to building supply line with a shut-off valve and install the in-line strainer between the valve and cooler.
5. Electrical: Make sure power supply is identical in voltage, cycle, and phase to that specified on cooler serial plate. Never wire compressor directly to the power supply.
6. This chiller has been designed for use with potable water ONLY.
LEGEND A = 1/4" O.D. TUBE W ATER OUTLET C = TEMPERATURE ADJUSTMENT B = 1/4" O.D. TUBE WATER INLET D = ELECTRICAL
3/8" O.D. UNPLATED
1/4" O.D. TUBE WATER INLET TO CHILLER
COPPER TUBE CONNECT COLD WA TER SUPPLY
BUILDING WA TER INLET
ST ART -UP
1. Open supply line valve.
2. Purge air from all water lines by operating bubbler valve of fountain to which cooler is connected. Steady stream assures all air is removed.
3. Rotate fan to insure proper clearance and free fan action.
4. Connect to electrical power.
TROUBLE SHOOTING & MAINTENANCE
Temperature Control: Factory set at 50°F (± 5°) under normal
conditions. For colder water, adjust screw on item no. 12 in clockwise direction. Ventilation: Cabinet louvers and condenser fins should be periodically cleaned with brush, air hose or vacuum cleaner. Excess dirt or poor ventilation can cause no cold water and compressor cycling on the compressor overload protector.
Lubrication: Motors are lifetime lubricated. Actuation of Quick Connect Water Fittings: Cooler is provided
with lead-free connectors which utilize an o-ring seal. To remove tubing from the fittings, relieve water pressure, push in on gray collar while pulling on the tubing. To insert tubing, push tube straight into fitting until it reaches a positive stop, approximately 3/4”.
OPERA TION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
NOTE: WA TER FLOW
DIRECTION
SERVICE STOP (NOT FURNISHED)
PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO
RELEASE TUBE
98198C (9/05)
115V ITEMIZED PARTS LIST
ITEM
NO.
10
*11
12 13 14 15 16 17 18 19 20 21 22 23 24
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.
NOTE: All correspondence pertaining to any of the above water cooler or orders for repair parts MUST include model number and serial number of cooler, name and part number of replacement part.
1 2 3 4 5 6 7 8 9
PART NO.
66534C 28478C 66743C 31490C 20282C 30664C 70018C 56237C 66576C 66703C 36094C 31513C 28477C 35768C 36158C
35959C 100806740570 101516143550
19037000
50930C
27303C
22300C
55996C
66723C
EVAPORATOR T ANK ASSY CABINET CONDENSER MOTOR - FAN 115V BRACKET - FAN MOUNTING BLADE - FAN NUT - FAN BLADE SHROUD - FAN HEAT EXCHANGER DRIER COMPRESSOR SERVICE PA K COLD CONTROL PANEL - FRONT COVER - RELAY OVERLOAD RELAY GROMMET STUD - COMP. MOUNTING CLIP BUMPER BASEPLATE PANEL - REAR IN-LINE STRAINER EVAPORA TOR TUBE
DESCRIPTION
HCR8*1J
22
23
3
4, 5, 6, 7, 8
WIRING DIAGRAM
13
2
1
9
24
20
1 1, 14, 15, 16,
10
12
21
98198C (9/05)
Loading...