EHFRA7C*A EHFRA7FC*A
Installation/Care/Use Manual
Fully Recessed Refrigerated
Fountain with FLEXI-GUARD
12, 13
®
9
21
SEE FIG. 5
14
SEE FIG. 9
Installer
To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE
NSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION
FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES.
After installation, leave these instructions inside the fountain for future reference.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY
OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO
A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE
IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER
MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE
OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.
Page 1
97160C (Rev. D - 10/16)

EHFRA7C*A EHFRA7FC*A
EHFRA7C ROUGH-IN
FINISHED
FLOOR LINE
FINISHED FLOOR
FIG. 1
LEGEND:
A = RECOMMENDED WATER SUPPLY LOCATION 3/8" O.D. UNPLATED COPPER TUBE CONNECT
STUB 1-1/2" (38mm) OUT FROM WALL, SHUT OFF BY OTHERS (BOTH SIDES).
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4" O.D. DRAIN (BOTH SIDES).
C = 1-1/4" TRAP NOT FURNISHED.
D = ELECTRICAL SUPPLY LOCATION (BOTH SIDES).
E = ACCESS TO TRAP MUST BE PROVIDED. IF REAR ACCESS IS NOT POSSIBLE, INSTALLATION
CAN BE MADE THROUGH OPTIONAL ACCESS PANEL AP-99.
97160C (Rev. D - 10/16)