SPECIFICATIONS
GENERAL
Self-contained, electric refrigerated floor model water cooler. Capacity of 50°F drinking water, based upon 80°F inlet water and 90°F ambient.
This model furnished with hermetically sealed combination tank-tube type cooling unit enclosed in cabinet. Cabinet design allows for flush to wall installation.
Non-pressurized tank system is standard. Non-pressurized water tank is located after bubbler valve, so that tank is sub­ject to line pressure only when valve button is pressed.
NO LEAD DESIGN
THIS WATER COOLER COMPLIES WITH THE LEAD-FREE DEFINI TION IN THE SAFE DRINKING WATER ACT OF 1986 AND LEAD CONTAMINATION CONTROL ACT OF
1988.
Elkay Water Coolers are manufactured with a waterway sys­tem utilizing copper components and completely lead-free material. These water ways have no lead because all lead materials, such as leaded brass, have been removed. All joints are brazed using silver solder only. No lead solder is permitted. A strainer with an easily cleanable screen is provided to allow trapping and con venient removal of water born particulate of 140 microns and larger prior to their entry into the water cooler.
CAPACITIES CHART
**GPH of 50°F Drinking Water
Model Base
Number Rate 70°F 80°F 90°F Watts Amps Option Lbs.
FD7003 FD7005 FD70010
**Based on 80°F inlet water temperature. †Glass filler available at extra cost. Requires factory preparation to receive glass
filler. Rated watts shown are based on operational (run) time, in compliance with ARI
Standard 1010 conditions. Specific applications will determine the actual watts consumed per hour. Watts consumed will be based on number of people served per hour (usage), ambient temperatures, and inlet water temperature.
Room Temperature °F
3.0 3.6 3.3 3.0 230 2.5 Yes 54
5.0 6.1 5.5 5.0 230 2.5 Yes 60
9.8 11.9 10.8 9.8 535 5.8 Yes 69
COOLING SYSTEM
Motor Compressor: Hermetically sealed, reciprocating type, 115V, 60 Hertz single phase. Sealed-in lifetime oil supply. Equipped with electric cord and three prong molded rubber plug.
Condenser: Fan cooled, copper tube with aluminum fins. Fan motor is permanently lubricated.
Cooling Unit: Combination tube-tank type. Tube portion is continuous coil of copper tubing. Fully insulated with EPS foam which meets Underwriters Laboratories Inc. require­ments for self extinguishing material.
Refrigerant Control: Refrigerant HFC-134a is controlled by accurately calibrated capillary tube for positively trouble free performance.
Temperature Control: Enclosed adjustable thermostat is factory pre-set. Requires no adjustment other than for alti­tude requirements.
Full Glass† Ship.
Rated Load Filler Wt.
No Lead Space-ette
Models FD7003, FD7005 and FD70010
Model FD7005
CONSTRUCTION
Cabinet: Cabinet wrapper supports fountain top and all working mechanisms. Stainless Steel cabinet available at extra cost.
Fountain Top: One piece stainless steel top, polished to a uniform Elkay bright luster finish. Unique Swirl-Flo basin has an integral vandal-resistant strainer, embossed bubbler pad.
®
Exclusive Flexi-Guard
utilizes an infused anti-microbial pliable polyester elastomer to prevent accidental mouth injuries. Flexes on impact, then returns to original position. Strong. Abrasion-resistant. Anti­sweat. Keyed in location to prevent rotation.
Protected by Elkay’s 5 Year Limited Warranty on the refrig­eration system of the unit.
Elkay Pressure-Type Water Coolers are designed to operate on 20 psi to 105 psi supply line pressure. If inlet pressure is above 105 psi, a pressure regulator must be installed in the supply line. Any damage caused by reason of connecting this product to supply line pressures lower than 20 psi or higher than 105 psi is not covered by the warranty.
STANDARDS
Elkay Electric Air Cooled Water Coolers are listed by Underwriters Laboratories Inc. and comply with both Canadian and U.S. requirements.
These units comply with A.R.I. Standard 1010.
This cooler is certified by WQA to lead-free compliance including
NSF/ANSI 61-ANNEX G, AB 1953.
Safety Bubbler: Innovative design
®
In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice. Please visit elkayusa.com for most current version of Elkay
product specification sheets.
Elkay
elkayusa.com
2222 Camden Court Oak Brook, IL 60523
This specification describes an Elkay product with design, quality and functional benefits to the user. When making a comparison of other producers’ offerings, be certain these features are not overlooked.
Printed in U.S.A. ©2011 Elkay
(Rev. 4/11) 9-5G
12"
(305mm)
4-1/2"
(114mm)
12"
(305mm)
4"
(102mm)
TOP VIEW
FRONT VIEW
38"
(965mm)
3-1/2"
(89mm)
7/8"
(22mm)
4"
(102mm)
2"
(51mm)
12"
(305mm)
31-1/2"
(800mm)
29"
(737mm)
1-1/4" (32mm) O.D. TAILPIECE
1-1/4" (32mm) DRAIN STUB OUT FROM WALL 1" (25mm)
3/8" S.P.S. SUPPLY STUB OUT FROM WALL 1" (25mm)
4 FOOT (1.2M)
LONG POWER CORD
SIDE VIEW
1-1/4" (32 mm)
O.D. TAILPIECE
TRAP BY OTHERS
TANK DRAIN
No Lead Space-ette
®
N
OTE: WATERFLOW
D
IRECTION SERVICE STOP
(NOT FURNISHED)
3/8" O.D. TUBE CONNECT
COLD WATER SUPPLY 1/4" O.D. TUBE
WATER INLET
TO COOLER BUILDING WATER
INLET
N
OTE: WATERFLOW
D
IRECTION
SERVICE STOP (NOT FURNISHED)
3/8" O.D. TUBE CONNECT COLD WATER SUPPLY
1/4" O.D. TUBE WATER INLET TO COOLER
BUILDING WATER
INLET
O
PERATION OF QUICK CONNECT FITTINGS
S
IMPLY PUSH IN
TUBE TO ATTACH
T
UBE IS SECURED
IN POSITION
P
USH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO
RELEASE TUBE
A
B
C
®
Floor-Mounted and Flush to Wall Water Cooler Models FD7003, FD7005 and FD70010
This water cooler has been designed and built to provide water to the user which has not been altered by materials in the cooler waterways.
The grounding of electrical equipment such as telephone, computers, etc., to water lines is a common procedure. This grounding may be in the building but may also occur away from the building. This grounding can cause electrical feedback into a water cooler creating an electrolysis which creates a metallic taste or causes an increase in the metal content of the water. This condition is avoidable by installing the cooler using the proper materials as shown below.
This water cooler must be connected to the water supply using a di­electric coupling. The cooler is furnished with a non-metallic strainer which meets this requirement.
The drain trap which is provided by the installer should also be plastic to completely isolate the cooler from the building plumbing system.
ROUGH-IN DIMENSIONS
IMPORTANT!
INSTALLER PLEASE NOTE:
NOTICE
Elkay
9-5G (Rev. 4/11)
2222 Camden Court Oak Brook, IL 60523
elkayusa.com
Printed in U.S.A. ©2011 Elkay