Floor-Mounted and Flush to Wall Water Cooler
SPECIFICATIONS
GENERAL
Self-contained, electric refrigerated floor model water cooler.
Capacity of 50°F drinking water, based upon 80°F inlet water
and 90°F ambient.
This model furnished with hermetically sealed combination
tank-tube type cooling unit enclosed in cabinet. Cabinet
design allows for flush to wall installation.
Non-pressurized tank system is standard. Non-pressurized
water tank is located after bubbler valve, so that tank is subject to line pressure only when valve button is pressed.
NO LEAD DESIGN
THIS WATER COOLER COMPLIES WITH THE LEAD-FREE
DEFINI TION IN THE SAFE DRINKING WATER ACT OF
1986 AND LEAD CONTAMINATION CONTROL ACT OF
1988.
Elkay Water Coolers are manufactured with a waterway system utilizing copper components and completely lead-free
material. These water ways have no lead because all lead
materials, such as leaded brass, have been removed. All
joints are brazed using silver solder only. No lead
solder is permitted. A strainer with an easily cleanable screen
is provided to allow trapping and con venient removal of
water born particulate of 140 microns and larger prior to their
entry into the water cooler.
CAPACITIES CHART
**GPH of 50°F Drinking Water
Model Base
Number Rate 70°F 80°F 90°F Watts Amps Option Lbs.
FD7003
FD7005
FD70010
**Based on 80°F inlet water temperature.
†Glass filler available at extra cost. Requires factory preparation to receive glass
filler.
Rated watts shown are based on operational (run) time, in compliance with ARI
Standard 1010 conditions. Specific applications will determine the actual watts
consumed per hour. Watts consumed will be based on number of people
served per hour (usage), ambient temperatures, and inlet water temperature.
Room Temperature °F
3.0 3.6 3.3 3.0 230 2.5 Yes 54
5.0 6.1 5.5 5.0 230 2.5 Yes 60
9.8 11.9 10.8 9.8 535 5.8 Yes 69
COOLING SYSTEM
Motor Compressor: Hermetically sealed, reciprocating type,
115V, 60 Hertz single phase. Sealed-in lifetime oil supply.
Equipped with electric cord and three prong molded rubber
plug.
Condenser: Fan cooled, copper tube with aluminum fins.
Fan motor is permanently lubricated.
Cooling Unit: Combination tube-tank type. Tube portion is
continuous coil of copper tubing. Fully insulated with EPS
foam which meets Underwriters Laboratories Inc. requirements for self extinguishing material.
Refrigerant Control: Refrigerant HFC-134a is controlled by
accurately calibrated capillary tube for positively trouble free
performance.
Temperature Control: Enclosed adjustable thermostat is
factory pre-set. Requires no adjustment other than for altitude requirements.
Full Glass† Ship.
Rated Load Filler Wt.
No Lead Space-ette
Models FD7003, FD7005 and FD70010
Model FD7005
CONSTRUCTION
Cabinet: Cabinet wrapper supports fountain top and all
working mechanisms. Stainless Steel cabinet available at
extra cost.
Fountain Top: One piece stainless steel top, polished to a
uniform Elkay bright luster finish. Unique Swirl-Flo basin has
an integral vandal-resistant strainer, embossed bubbler pad.
®
Exclusive Flexi-Guard
utilizes an infused anti-microbial pliable polyester elastomer
to prevent accidental mouth injuries. Flexes on impact, then
returns to original position. Strong. Abrasion-resistant. Antisweat. Keyed in location to prevent rotation.
Protected by Elkay’s 5 Year Limited Warranty on the refrigeration system of the unit.
Elkay Pressure-Type Water Coolers are designed to operate
on 20 psi to 105 psi supply line pressure. If inlet pressure is
above 105 psi, a pressure regulator must be installed in the
supply line. Any damage caused by reason of connecting this
product to supply line pressures lower than 20 psi or higher
than 105 psi is not covered by the warranty.
STANDARDS
Elkay Electric Air Cooled Water Coolers are listed
by Underwriters Laboratories Inc. and comply with
both Canadian and U.S. requirements.
These units comply with A.R.I. Standard 1010.
This cooler is certified by WQA to lead-free compliance including
NSF/ANSI 61-ANNEX G, AB 1953.
Safety Bubbler: Innovative design
®
In keeping with our policy of continuing product improvement, Elkay reserves the right to change
product specifications without notice. Please visit elkayusa.com for most current version of Elkay
product specification sheets.
Elkay
elkayusa.com
2222 Camden Court
Oak Brook, IL 60523
This specification describes an Elkay product with design, quality and functional benefits to the
user. When making a comparison of other producers’ offerings, be certain these features are not
overlooked.
Printed in U.S.A.
©2011 Elkay
(Rev. 4/11) 9-5G
12"
(305mm)
4-1/2"
(114mm)
12"
(305mm)
4"
(102mm)
TOP VIEW
FRONT VIEW
38"
(965mm)
3-1/2"
(89mm)
7/8"
(22mm)
4"
(102mm)
2"
(51mm)
12"
(305mm)
31-1/2"
(800mm)
29"
(737mm)
1-1/4" (32mm)
O.D. TAILPIECE
1-1/4" (32mm)
DRAIN STUB
OUT FROM
WALL 1" (25mm)
3/8" S.P.S. SUPPLY
STUB OUT FROM
WALL 1" (25mm)
4 FOOT (1.2M)
LONG POWER CORD
SIDE VIEW
1-1/4" (32 mm)
O.D. TAILPIECE
TRAP BY OTHERS
TANK DRAIN
No Lead Space-ette
N
OTE: WATERFLOW
D
IRECTION
SERVICE STOP
(NOT FURNISHED)
3/8" O.D. TUBE CONNECT
COLD WATER SUPPLY
1/4" O.D. TUBE
WATER INLET
TO COOLER
BUILDING WATER
INLET
N
OTE: WATERFLOW
D
IRECTION
SERVICE STOP
(NOT FURNISHED)
3/8" O.D. TUBE CONNECT
COLD WATER SUPPLY
1/4" O.D. TUBE
WATER INLET
TO COOLER
BUILDING WATER
INLET
O
PERATION OF QUICK CONNECT FITTINGS
S
IMPLY PUSH IN
TUBE TO ATTACH
T
UBE IS SECURED
IN POSITION
P
USH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
A
B
C
®
Floor-Mounted and Flush to Wall Water Cooler
Models FD7003, FD7005 and FD70010
This water cooler has been designed and built to provide water to the
user which has not been altered by materials in the cooler waterways.
The grounding of electrical equipment such as telephone, computers,
etc., to water lines is a common procedure. This grounding may be
in the building but may also occur away from the building. This grounding
can cause electrical feedback into a water cooler creating an electrolysis
which creates a metallic taste or causes an increase in the metal content
of the water. This condition is avoidable by installing the cooler using the
proper materials as shown below.
This water cooler must be connected to the water supply using a dielectric coupling. The cooler is furnished with a non-metallic strainer
which meets this requirement.
The drain trap which is provided by the installer should also be plastic to
completely isolate the cooler from the building plumbing system.
ROUGH-IN DIMENSIONS
IMPORTANT!
INSTALLER PLEASE NOTE:
NOTICE
Elkay
9-5G (Rev. 4/11)
2222 Camden Court
Oak Brook, IL 60523
elkayusa.com
Printed in U.S.A.
©2011 Elkay