Elkay EZOSTL8LC Specifications

Page 1
Versatile Bi-Level Wall Mount Water Cooler
Hands Free® Sensor & Pushbar Activated
PRODUCT SPECIFICATION
Self-contained wall mount sensor-activated electric two-level water cooler. Model EZOSTL8 shall deliver 8 GPH of 50°F drinking water at 90°F ambient and 80°F inlet water. Right-hand unit shall have electronic sensor-operated Hands-Free® operation. Left-hand unit shall have self-closing Easy-Touch Controls on front, left and right. Unit shall meet ADA guidelines. Unit shall
be lead-free design which is certied to NSF/ANSI 61 and 372 and meets Federal and State low-lead requirements. Unit shall be certied to UL399 and CAN/CSA 22.2 No. 120.
STANDARD FEATURES
• Electronic sensor-operated Hands-Free® operation on right-hand unit
• Easy-Touch front and side pushbar controls on left-hand unit
• Available with Flexi-Guard® Safety bubbler or Vandal-resistantt bubbler
Vandal-resistantt bubbler (tincludes “VR” code in model no.)
• *Versatile cooler design allows units to be installed either left-hand high and right-hand low or left-low and right high
• Cooler panel nishes: Light Gray Granite Vinyl Clad Steel or
Stainless Steel
• Rated for indoor Use
COOLING SYSTEM (Model EZOSTL8)
• Compressor: Hermetically-sealed, reciprocating type, single phase.
Sealed-in lifetime lubrication.
• Condenser: Fan cooled, copper tube with aluminum ns. Fan motor is
permanently lubricated.
• Cooling Unit: Tube type. Self-cleansing. Continuous Copper tubing
which is fully insulated with EPS foam that meets UL requirements for self-extinguishing material.
• Refrigerant Control: Refrigerant R134a is controlled by accurately
calibrated capillary tube.
• Temperature Control: Easily accessible enclosed adjustable thermostat is factory preset. Requires no adjustment other than for altitude
requirements.
Warranty: 5 year limited warranty on the unit’s refrigeration system. Electrical components and water system are warranted for 12 months from date of installation or 18 months from factory shipment,
whichever date falls rst.
Model EZOSTL8
RATED FOR INDOOR USE ONLY
*Versatile cooler conguration
as shipped
*Versatile cooler conguration
alternate installation
CONSTRUCTION
• Electronic Hands-Free® operation: On-off solenoid valve is
actuated by an infrared light beam sensor. When light beam is interrupted by user in front of cooler, the sensor actuates to begin water dispensing. A built-in time delay is provided to prevent
actuation by passerby trafc.
• Fountain Top: One piece stainless steel top, polished to a uniform Elkay satin luster nish
• Frame: Galvanized steel chassis support
• Exclusive Flexi-Guard® Safety bubbler: Innovative design utilizes
an infused anti-microbial pliable polyester elastomer to prevent
accidental mouth injuries. Flexes on impact.
• Vandal-resistant bubbler (option) is one-piece heavy-duty
• Upper Shroud: Contoured shock-absorbing provides additional protection against accidental injury. No exposed fasteners.
• Removable Wrapper: One-piece design offers easy accessibility
to interior
• Cooler cabinet available as Light Gray Granite Vinyl Clad Steel or Stainless Steel (additional cost) construction
CAPACITIES CHART
UL399 and
CAN/CSA 22.2
No. 120
Certied
ADA
COMPLIANT
ANSI/NSF
61 and 372
Certied
Model Voltage / Hertz
Chilling**
Capacity
F.L.
Amps
Rated Watts
Approx.
Ship
Wt.
EZOSTL(VR)8*C 115V / 60Hz 8 GPH 4.0 370 72 lbs • • •
EZOSTL8*2JOC 220V / 50Hz 6.7 GPH 2.0 370 72 lbs ++ • •
EZOSTL8*3JOC 220V / 60Hz 8 GPH 2.0 370 72 lbs ++ • •
*Color code of (L) Light Gray Granite or (S) Stainless Steel cooler panels. **Based on 80°F inlet water & 90°F ambient air temp for 50°F chilled drinking water.
++Complies; not third party certied.
In keeping with our policy of continuing product improvement,
Elkay reserves the right to change specication without notice. Please visit elkay.com for the most current version.
2222 Camden Court
Oak Brook, IL 60523
630-572-3192
elkay.com
This specication describes an Elkay product with design, quality and functional benets to the user. When making a comparison of other producer’s offerings, be certain these features are not overlooked.
© 2014 Elkay
SPEC12-27 (06/2014)
Page 2
Versatile Bi-Level Wall Mount Water Cooler Hands Free® Sensor & Pushbar Activated Model EZOSTL8
IMPORTANT! INSTALLER PLEASE NOTE:
These units are designed and built to provide water to the user which has not been altered by materials in the cooler waterway. The grounding of electrical equipment such as telephone, computers, etc. to water lines is a common procedure. This grounding may be in the building but may also occur away from the building. This grounding can cause electrical feedback into a water cooler creating an electrolysis which results in a metallic taste or an increase in the metal content of the water. This condition is avoidable by installing the cooler using the proper materials as shown.
Model shown with Flexi-Guard® bubbler.
ROUGH-IN FOR LEFT-HAND HIGH SIDE MODELS
18 3/8"
2"
51mm
9/32" 7mm
DIA. ((12)
6 3/8"
162mm
467mm
‰
6 3/8"
162mm
18 3/8"
467mm
6 3/8"
162mm
162mm
‰
6 3/8"
ROUGH-IN DIMENSIONS
RATED FOR INDOOR USE ONLY
NOTICE
This water cooler must be connected to the water supply using a dielectric coupling. The cooler is furnished with a non-metallic strainer which meets this requirement. The drain trap which is provided by the installer should also be plastic to completely isolate the cooler from the building plumbing system.
19"
483mm
HANGER BRACKET
2"
17 7/16"
443mm
51mm
7/8"
22mm
13 15/16" 354mm
B
F
3 7/8"
98mm
5 3/4"
146mm
7"
178mm
FINISHED FLOOR
A
PREFFERED
LOCATION
2"
51mm
7"
178mm
34 5/16" 872mm
(ALT. LOCATION)
24 1/2"
622mm
22 15/16"
583mm
A
E
F
19 7/16" 494mm
D
PREFFERED
LOCATION
REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER
LEGEND:
A = Recommended Water Supply location. Shut-off Valve (not furnished) to accept
3/8” O.D. unplated copper tube. Up to 3” (76mm) maximum out from wall.
B = Recommended Waste Outlet location. To accommodate 1-1/2” nominal drain. Drain stub 2” (51mm) out from wall. C = 1-1/2” Trap (not furnished).
D = Electrical Supply (3) Wire Recessed Box Duplex Outlet. E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from cabinet
louvers to wall. F = 7/16” (11mm) Bolt Holes for fastening to wall.
NOTE: New Installations Must Use Ground Fault Circuit Interrupter (GFCI)
19"
483mm
2"
51mm
38 3/8"
975mm
ORIFICE
HEIGHT
E
21 7/8"
556mm
28 13/16"
732mm
36 13/16"
936mm
RIM
HEIGHT
32 7/8"
835mm
ORIFICE HEIGHT
31 5/16" 796mm
RIM
HEIGHT
REQUIREMENT
27"
686mm
ADA
C
12 1/2"
318mm
1 7/16" 37mm
3"
76mm
Job Name: ____________________________________ Model: _______________________ Qty. ____________ Contact: ______________________________________ Approval Signature: _____________________________ Notes:
Page 2
2222 Camden Court
Oak Brook, IL 60523
630-572-3192
elkay.com
Printed in U.S.A.
© 2014 Elkay
Page 3
Versatile Bi-Level Wall Mount Water Cooler Hands Free® Sensor & Pushbar Activated Model EZOSTL8
IMPORTANT! INSTALLER PLEASE NOTE:
These units are designed and built to provide water to the user which has not been altered by materials in the cooler waterway. The grounding of electrical equipment such as telephone, computers, etc. to water lines is a common procedure. This grounding may be in the building but may also occur away from the building. This grounding can cause electrical feedback into a water cooler creating an electrolysis which results in a metallic taste or an increase in the metal content of the water. This condition is avoidable by installing the cooler using the proper materials as shown.
Model shown with Flexi-Guard® bubbler.
ROUGH-IN FOR RIGHT-HAND HIGH SIDE MODELS
18 3/8"
2"
51mm
28 13/16"
732mm
9/32" 7mm
A
(ALT. LOCATION)
21 7/8"
556mm
O
(12)
E
13 15/16" 354mm
F
19"
483mm
6 3/8"
162mm
98mm
7"
178mm
3 7/8"
467mm
‰
6 3/8"
162mm
7/8"
22mm
2"
51mm
7"
178mm
B
18 3/8"
467mm
162mm
D
PREFFERED
LOCATION
6 3/8"
5 3/4"
146mm
FINISHED FLOOR
‰
6 3/8"
162mm
D
ALT. LOCATION
2"
51mm
ROUGH-IN DIMENSIONS
RATED FOR INDOOR USE ONLY
NOTICE
This water cooler must be connected to the water supply using a dielectric coupling. The cooler is furnished with a non-metallic strainer which meets this requirement. The drain trap which is provided by the installer should also be plastic to completely isolate the cooler from the building plumbing system.
19"
484mm
HANGER
BRACKET
2"
51mm
38 3/8"
34 5/16" 872mm
975mm
ORIFICE HEIGHT
36 13/16"
936mm
RIM
HEIGHT
32 7/8"
835mm
ORIFICE HEIGHT
31 5/16" 796mm
RIM
HEIGHT
27"
686mm
ADA
REQUIREMENT
8 1/16"
205mm
C
12 1/2"
318mm
1 7/16"
37mm
3"
76mm
F
REFERRED
LOCATION
19 7/16"
494mm
E
A
22 15/16"
583mm
24 1/2"
622mm
REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER
LEGEND:
A = Recommended Water Supply location. Shut-off Valve (not furnished) to accept
3/8” O.D. unplated copper tube. Up to 3” (76mm) maximum out from wall.
B = Recommended Waste Outlet location. To accommodate 1-1/2” nominal drain. Drain stub 2” (51mm) out from wall. C = 1-1/2” Trap (not furnished).
D = Electrical Supply (3) Wire Recessed Box Duplex Outlet. E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from cabinet
louvers to wall. F = 7/16” (11mm) Bolt Holes for fastening to wall.
NOTE: New Installations Must Use Ground Fault Circuit Interrupter (GFCI)
2222 Camden Court
Page 3
Oak Brook, IL 60523
630-572-3192
elkay.com
Job Name: ____________________________________ Model: _______________________ Qty. ____________ Contact: ______________________________________ Approval Signature: _____________________________ Notes:
Printed in U.S.A.
© 2014 Elkay
Loading...